Valid

HJ 2508-2011Technical requirement for environmental labeling products. Phones (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (12 pages)

Need quotation for your management?

Get a formal quotation for HJ 2508-2011 in 30 minutes.

Issued by

Ministry of Ecology and Environment

Level / Type

National · Mandatory

Issue date

March 2, 2011

Implementation date

April 1, 2011

Scope

HJ 2508-2011 (Technical requirement for environmental labeling products. Phones) is available as an English-translated PDF.

HJ 2508-2011 — This standard specifies the terms and definitions, basic requirements, technical content and testing methods of telephone environmental labeling products. This standard applies to telephones, including wireline and mobile phones.

Found what you need?

Document preview — HJ 2508-2011

National Standard of the People's Republic of China

ICS
33.040.60
Classification
M 40

Issued by: Ministry of Ecology and Environment

Contents

  • Foreword
  • 1 Scope of application
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Basic requirements
  • 5 Technical content
  • 5.1 Wired telephone
  • 5.2 Mobile Phone
  • 5.3 Product requirements
  • 7 Lead (Pb) is used in high temperature solders and its content (mass fraction) >= 85%
  • 9 Lead (Pb) is used in the internal bonding solder of integrated circuit flip chip packages

Foreword

To implement the Environmental Protection Law of the People's Republic of China, reduce the impact of telephone calls on the environment and human health, effectively use and conserve resources, Energy, develop this standard.

This standard measures the leakage current of wired telephones, the average efficiency of external power adapters, electromagnetic radiation of mobile phones, and power supply chargers.

Average efficiency and the limits of toxic and hazardous substances in the phone, design, production process, packaging materials, recycling and public information the request.

This standard is the first release.

Appendix A and Appendix B of this standard are normative appendices.

This standard applies to China Environmental Labeling Product Certification.

This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.

This standard is mainly drafted by. China-Japan Friendship Environmental Protection Center, China Taier Laboratory.

This standard was approved by the Ministry of Environmental Protection on March 2, 2011.

This standard has been implemented since April 1, 2011.

This standard is explained by the Ministry of Environmental Protection.

Environmental Labeling Product Technical Requirements Telephone

1 Scope of application

This standard specifies the terms and definitions, basic requirements, technical content and testing methods of telephone environmental labeling products.

This standard applies to telephones, including wireline and mobile phones.

2 Normative references

The contents of this standard refer to the terms in the following documents. For undated references, the valid version applies to this standard.

GB/T 18455 packaging recycling mark GB/T 15279 automatic telephone technical conditions GB/T 16288 logo for plastic products GB/Z 20288-2006 General requirements for the separation of test samples for hazardous substances in electrical and electronic products SJ/T 11365-2006 Methods for the detection of toxic and hazardous substances in electronic information products SN/T 1877.2-2007 Method for determination of polycyclic aromatic hydrocarbons in plastics and their products YD/T 1591 mobile communication terminal power adapter and charging/data interface technical requirements and test methods YD/T 1644.1-2007 Electromagnetic irradiation of human body by wireless communication equipment for hand-held and body wear--human body model, instrument and the first part of the procedure. SAR evaluation procedures for handheld wireless communication devices used near the ear (frequency range 300 MHz to 3 GHz) YD/T 1760.1 Digital mobile terminal peripheral interface data exchange Part 1. Data format technical requirements YD/T 1760.2 Digital mobile terminal peripheral interface data exchange Part 2. Data exchange file format technical requirements YD/T 1885 mobile communication handset wired headset interface technical requirements and test methods

3 Terms and definitions

The following terms and definitions apply to this standard.

Phone phone

Fixed telephone terminals, cordless telephone terminals and mobile connected to public communication networks (including fixed communication networks and wireless communication networks) User terminal products.

Wired telephone wirephone it is connected to a fixed telephone terminal and a cordless telephone terminal product in a public fixed communication network.

Mobile phone

Connected to a mobile user terminal product within a public wireless communication network.

4 Basic requirements

4.1 Product quality and safety performance should meet the requirements of relevant standards.

4.2 Pollutant emissions from product manufacturing enterprises shall comply with national or local standards for pollutant discharge.

4.3 Product manufacturers should strengthen clean production in the production process.

5 Technical content

5.1 Wired telephone

5.1.1 Only wired telephones with telephone line power supply and LCD display shall have leakage current in the on-hook state in accordance with GB/T 15279.

Requirements; other wired telephones that are only powered by telephone lines should have a leakage current of no more than 20 µA in the on-hook state.

5.1.2 For wired telephones powered by an external power supply, the actual average efficiency of the external power adapter shall comply with the requirements of YD/T 1591.

5.2 Mobile Phone

5.2.1 The electromagnetic radiation specific absorption rate (SAR) value of mobile phones should be no more than 0.8 W/kg.

5.2.2 Mobile phone power charger and charging/data interface shall comply with YD/T 1591 requirements.

5.2.3 Mobile phone wired headset interface shall comply with YD/T 1885 requirements.

5.2.4 The data format of the mobile phone software shall comply with the requirements of YD/T 1760.1, and the data exchange file format shall conform to YD/T 1760.2.

Claim.

5.3 Product requirements

5.3.1 The limit of toxic and hazardous substances in homogeneous materials in products shall comply with the requirements of Table 1.

Table 1 Limits of toxic and hazardous substances in homogeneous materials in products 1

Project limit (quality score) Lead (Pb) <= 0.1% Mercury (Hg) <= 0.1% Cadmium (Cd) <=0.01% Hexavalent chromium (Cr6) <=0.1% Polybrominated biphenyls (PBBs) <=0.1% Polybrominated diphenyl ethers (PBDEs) <=0.1%

Note 1. Exemptions can be waived for exceptions. See Table 2 for exceptions.

Table 2 Exceptional Limits for Toxic and Hazardous Substances in Homogeneous Materials in Products

Serial number content

1 Lead (Pb) is applied to the glass of electronic components

2 Lead (Pb) and cadmium (Cd) are used in optical glass and filter glass

3 Lead (Pb) is used in ceramics of electronic ceramic parts

4 Lead (Pb) is used as an alloying component in steel alloys and its content (mass fraction) <=0.35%

5 Lead (Pb) is used as an alloying component in aluminum alloys and its content (mass fraction) <=0.4%

6 Lead (Pb) is used as an alloying component in copper alloys and its content (mass fraction) <= 4%

7 Lead (Pb) is used in high temperature solders and its content (mass fraction) >= 85%

8 Lead (Pb) is used in the solder used for microprocessor pins and package connections, and its content (mass fraction) is 80% to 85%.

9 Lead (Pb) is used in the internal bonding solder of integrated circuit flip chip packages

10 Lead (Pb) is used in the surface treatment of fine pitch components (except connectors) with a pitch not exceeding 0.65 mm and with an iron-nickel lead frame or a copper lead frame

5.3.2 Product enclosures and cables Polycyclic aromatic hydrocarbons (PAHs) in plastic materials shall meet the requirements of Table 3.

Table 3 Polycyclic Aromatic Hydrocarbons (PAHs) in Product Shells and Cable Plastic Materials

Project limit (quality score) Benzo[a]pyrene (BaP) <=0.000 1% Naphthalene, AcPy, Acp, Flu, PA, Ant, Fluoride (FL), Pyr (Pyr), Quinoa (CHR), benzo[a]pyrene (BaA), benzo[b]fluoranthene (BbF), benzo[k]fluoranthene (BkF), benzo[a]pyrene (BaP), Dibenzo[a,h]indole (DBA), indene [1,2,3-cd]indole (IND), benzo[g,h,i]indole (BghiP) 16 polycyclic aromatic hydrocarbons (PAHs) sum <=0.001%

5.3.3 Product design requirements

5.3.3.1 The parts of the product shall be standardized.

5.3.3.2 The same size battery of the mobile phone should be used in at least 3 models of mobile phones.

5.3.4 Product production process requirements Hydrochlorofluorocarbons (HCFCs), 1,1,1-trichloroethane (C2H3Cl3), trichloroethylene should not be used in the production of products and boards.

(C2HCl3), dichloroethane (CH3CHCl2), chloroform (CHCl3), bromopropane (C3H7Br), n-hexane (C6H14), toluene (C7H8), Xylene [C6H4(CH3)2] was used as a washing solvent.

5.3.5 Material identification requirements the abbreviations or codes of the material identification shall comply with the requirements of GB/T 16288.

5.3.6 Packaging material requirements

5.3.6.1 The content of vinyl chloride monomer shall not exceed 1 mg/kg.

5.3.6.2 Hydrochlorofluorocarbons (HCFCs) should not be used as blowing agents.

5.3.6.3 Mark according to the requirements of GB/T 18455.

5.3.7 Recycling and disposal requirements Enterprises should establish waste product recycling and recycling treatment systems to provide information on product recycling and recycling.

5.3.8 Public Information Requirements 5.3.8.1 should include product recycling information.

5.3.8.2 The mobile phone shall include the average power consumption information during the call and standby states.

6 Test methods

6.1 Technical content 5.1.1 The test shall be carried out in accordance with the method specified in GB/T 15279.

6.2 Technical content The detection of 5.1.2 and 5.2.2 is carried out in accordance with the method specified in YD/T 1591.

6.3 Technical content The detection of 5.2.1 is carried out in accordance with the method specified in YD/T 1644.1-2007.

6.4 Technical content The detection of 5.2.3 is carried out in accordance with the method specified in YD/T 1885.

6.5 Technical content The detection of 5.3.1 is carried out in accordance with the method specified in SJ/T 11365-2006.

6.6 Technical content The detection of 5.3.2 shall be carried out in accordance with the method specified in SN/T 1877.2-2007, and the sample preparation shall be in accordance with the method specified in Appendix A.

get on.

6.7 Technical content The average power consumption test in 5.3.8.2 is carried out by the enterprise in accordance with the method specified in Appendix B.

6.8 Other requirements in the technical content shall be verified by means of document review in conjunction with on-site inspection.

Appendix A

(normative appendix) Preparation of polycyclic aromatic hydrocarbons test samples in plastic materials A.1 Method summary the method is used to prepare a test sample of polycyclic aromatic hydrocarbons (PAHs) in a plastic material. The split sample is pulverized to 2 to 3 by a grinder Mm, weigh the sample mass about 0.5 g, add the internal standard substance and 20 ml of toluene, and extract it in a 60 ° C ultrasonic water bath for 1 h, then cool to the room.

After the temperature, the test was carried out in accordance with the method specified in SN/T 1877.2-2007.

A.2 Equipment and materials A.2.1 Equipment

a) a fume hood for the experiment;

b) grinding machine (liquid nitrogen cooling);

c) electronic analytical balance, accurate to 0.1 mg;

d) microinjection needles;

e) needle sample filter (organic system);

f) pipetting gun 20 ~.200 µl,.200 ~ 1 000 µl;

g) Glassware. chromatography bottle (2 ml), volumetric flask, 20/10 ml headspace bottle, beaker;

h) ultrasonic cleaner, centrifuge;

i) Centrifuge tubes and thermometers.

A.2.2 Reagents and other

a) internal standard and reference materials

1) Internal standard. Acenaphthene-d10, Chrysene-d12, Phenanthrene-d10.

2) PAHs reference materials.

Table A.1 PAHs Reference Materials

Compound Chinese name compound English name short name Naphthalene Napene Nap Terenaphthylene AcPy 苊Acenaphthene Acp 芴Fluorene Flu Philippine Phenanthrene PA 蒽Anthracene Ant Fluoranthine Fluoranthene FL 芘Pyrene Pyr Quarry Chrysene CHR Benzo[a]蒽Benzo[a]anthracene BaA Benzo[b]fluoranthene Benzo[b]fluoranthene BbF Benzo[k]fluoranthene Benzo[k]fluoranthene BkF Continued Compound Chinese name compound English name short name Benzo[a]芘Benzo[a]pyrene BaP Dibenzo[a,h]蒽Dibenzo[a,h]anthrancene DBA Benzene [1,2,3-cd]芘Indeno[1,2,3-cd]pyrene IND Benzo[g,h,i]芘Benzo[g,h,i]perylene BghiP PAHs 16 compound mixed standard.200 µg/ml

3) Quasi-standard product. 1-fluoronaphthalene.

b) reagent

Toluene. analytically pure; toluene. chromatographically pure.

c) carrier gas

Pure helium. purity 99.999%.

A.3 Standard solution preparation requirements Before the chromatographic analysis, the standard solution should be prepared using the above standard materials, and the working curve should be used. The standard curve concentration point (excluding the zero point) is Five points less.

A.4 Sample preparation A.4.1 Number of samples If the sample to be tested needs to be removed from the finished product or component, the sample is split according to the national standard GB/Z 20288-2006. Split the amount of sample material should be no less than 5 g.

A.4.2 Sample preparation the sample to be tested is pulverized to 2 to 3 mm, and a sample weighing approximately 500 mg can be weighed accurately to a sample weighing about 500 mg and the actual number is recorded.

Take the quality.

A.4.3 Sample extraction Add 20 ml of toluene (adding internal standard) to the headspace bottle, press the aluminum cover and place in an ultrasonic water bath.

At 60 ° C. The mixture was shaken for 1 h using ultrasonic waves, and after extraction, it was taken out and allowed to cool to room temperature.

A.4.4 Sample purification After standing, transfer the sample solution to the centrifuge tube, place it symmetrically, turn on the centrifuge, and centrifuge for 5 min (4 000 r/min). Take the supernatant 1 to 2 ml, filter with a syringe and an organic filter (0.45 µm), transfer the filtrate to a chromatography bottle, shake and prepare for testing.

A.5 Test project

The following 16 polycyclic aromatic hydrocarbon compounds were tested according to the method specified in SN/T 1877.2-2007.

Table A.2 16 polycyclic aromatic hydrocarbon compounds

Compound Chinese name compound English name short name Naphthalene Napene Nap Terenaphthylene AcPy 苊Acenaphthene Acp 芴Fluorene Flu Continued Compound Chinese name compound English name short name Philippine Phenanthrene PA 蒽Anthracene Ant Fluoranthine Fluoranthene FL 芘Pyrene Pyr Quarry Chrysene CHR Benzo[a]蒽Benzo[a]anthracene BaA Benzo[b]fluoranthene Benzo[b]fluoranthene BbF Benzo[k]fluoranthene Benzo[k]fluoranthene BkF Benzo[a]芘Benzo[a]pyrene BaP Dibenzo[a,h]蒽Dibenzo[a,h]anthrancene DBA Benzene [1,2,3-cd]芘Indeno[1,2,3-cd]pyrene IND Benzo[g,h,i]芘Benzo[g,h,i]perylene BghiP Appendix B (normative appendix) Detection of average current of mobile phone during call and standby B.1 Overview the following abbreviations apply to this appendix.

AMR Adaptive Multi Rate Adaptive Multirate CDMA Code Division Multiple Access Code Division Multiple Access CPICH Common Pilot Channel Common Pilot Channel DPCH Dedicated Physical Channel DRX discontinuous Receive DTX Discontinuous Transmission GPRS General Packet Radio Service GSM Global System for Mobi le Communications Global System for Mobile Communications MMS Multimedia Message Service Multimedia Information Service PCCPCH Primary Common Control Physical Channel PCL Power Control Level RSCP Received Signal Code Power Receive Signal Code Domain Power SIM Subscriber Identity Module User Authentication Module SMS Short Messaging Service short message service SS System Simulator System Simulator TDMA Time Division Multiple Access Time Division Multiple Access TD-SCDMA Time Division Synchronize Code Time Division Synchronous Code Division Multiple Access Division Multiple Access UE User Equipment User Equipment WCDMA Wideband Code Division Multiple Access Wideband Code Division Multiple Access the schematic diagram of the mobile terminal power consumption test system, as shown in Figure B.1, includes the network environment, the current acquisition system, and the terminal under test.

DC power supply and electricity Flow collection device UE the internet

Figure B.1 Power Test System Schematic

Considering the consistency and compatibility of the UE's Uu interface, as a simplified way, allowing the use of a system simulator (base station simulation Replace the real network test environment for power consumption testing of the terminal. This system simulator (base station simulator) should be detected by the entity or provided by a third-party test equipment R&D entity, and the Uu interface shall comply with the 3GPP/3GPP2 specifications. The terminal transceiver should meet the corresponding Industry standard requirements.

The power consumption test system is shown in Figure B.2 and Figure B.3.

DC power supply

Control computer

Data line

system

Simulator

Figure B.2 Schematic diagram of DC source power consumption test system

Control computer

system

Simulator

Data line

battery

Figure B.3 Schematic diagram of battery power consumption test system

Instrument Description. The main test instruments are high precision current/voltmeter and system simulator. High precision current/voltage meter as mobile terminal the test device is consumed; the system simulator establishes various communication service states with the UE. The measurement requirements of the test equipment are shown in Table B.1 and Table B.2.

Table B.1 Standby measurement requirements

Measurement condition requirement limit Measuring resistance <=0.5 ohm Accuracy/Type 1%, 0.5 W, High Precision Metal Film Resistors Sampling rate >=50,000 times/s Resolution <=0.1 mA Noise floor is less than the lowest ADC step

Table B.2 Business Measurement Requirements

Measurement condition requirement limit Measuring resistance <=0.1 ohm Accuracy/Type 1%, 2 W, High Precision Metal Film Resistors Sampling rate >=50,000 times/s Resolution <=0.5 mA Noise floor is less than the lowest ADC step

Note 1. It is recommended to establish a good connection between the comprehensive tester and the mobile terminal; the mobile terminal is shielding the environment to avoid interference.

Note 2. It is recommended to use a resistor with a sensing wire. Otherwise, you need to measure the resistance accurately and consider the impedance of the connecting cable.

B.2 Standby power test B.2.1 Test conditions the network environment adopted by this standard is an analog network. If there are no conditions, the live network environment can also be used in the test, but the existing network environment should be adopted.

Be explained.

Table B.3 General parameter settings

Set parameter settings value comments Cell reselection without -Cell broadcast no -SIM/USIM/UIM card - support clock stop mode SMS/MMS None -PLMN Local -Additional business closed -Terminal additional function is off -B.2.1.1 GSM/GPRS terminal B.2.1.1.1 GSM/GPRS general network environment

Table B.4 GSM/GPRS Universal Network Environment Parameter Settings

Set parameter settings value comments the center frequency of the frequency band in which the working frequency band UE works shall indicate the terminal frequency band in the test result.

UE receive level -82 dBm -Switch settings no -BA list (Note) 16 -DTX None -DRX 7 This value is the default value. If you choose other values, it should be indicated in the test results.

Adjacent cell no -

Periodic location update off T3212 = 0 Note. The neighbor cell is required to be measured according to the list, but the SS does not provide the neighbor cell signal to avoid the terminal from initiating synchronization.

B.2.1.1.2 GPRS network environment

Table B.5 GPRS network environment parameter settings

Set parameter settings value comments DRX 7 This value is the default value. If you choose other values, it should be indicated in the test results.

Network operation mode Note 1 -Paging channel CCCH-PCH -Adjacent cell no -Note. The network operation mode indicates that all paging information is sent over the PPCH channel. If there is no PPCH channel, it can also be sent using the CCCH-PCH channel. when CS domain paging signaling is transmitted by the PDTCH channel when the PS domain is connected.

Table B.6 BA list neighbor cell channel number

Parameter working band parameter value Neighbor cell channel number 900 bands 1,9,17,26,34,42,50,58,67,75,83,91,99,108,116,124 1800 bands 512,536,560,585,610,635,660,685,710,735,760,785,810,835, 860,885 B.2.1.1.3 Terminal settings

Table B.7 Terminal Settings

Set parameter settings Other auxiliary peripherals such as Bluetooth/infrared/camera are off no button press volume-Display power saving mode the backlight is off or set to a minimum B.2.1.2 TD-SCDMA terminal B.2.1.2.1 Network environment

Table B.8 Network Environment Parameter Settings

Set parameter settings value comments Frequency band center frequency in which the working frequency band UE works the terminal frequency band should be indicated in the test result 2010-2025 MHz band Median.2017.4 MHz (This value is the default value. If other frequency bands are involved, please indicate in the result) There are no less than 4 neighboring cell lists -PCCPCH RSCP -80 dBm -DRX 7 This value is the default value. If you choose other values, it should be indicated in the test results.

Periodic position update off T3212=0 B.2.1.2.2 Terminal settings

Table B.9 Terminal Settings

Set parameter settings Other auxiliary peripherals such as Bluetooth/infrared/camera are off no button press volume-Display power saving mode the backlight is off or set to a minimum B.2.1.3 WCDMA terminal B.2.1.3.1 Network environment

Table B.10 Network Environment Parameter Settings

Set parameter settings value comments the center frequency of the frequency band in which the working frequency band UE works shall indicate the terminal frequency band in the test result.

List of neighboring cells (Note) 16 -DRX 7 This value is the default value. If you choose other values, it should be indicated in the test results.

CPICH_RSCP(Ec) (Common Pilot Channel) Received power) -82 dBm -DPCH_Ec/Ior -5 dB -Ec/No >-12 dB -Periodic location update off T3212 = 0 Note. It is required to measure the same-frequency neighboring cell according to the list, but the SS does not provide the neighboring cell signal to avoid the terminal from initiating synchronization.

Note 3. By default, only the intra-frequency neighbor cell search is performed. If there are other settings, please indicate in the test results.

B.2.1.3.2 Terminal settings

Table B.11 Terminal Settings

Set parameter settings Other auxiliary peripherals such as Bluetooth/infrared/camera are off no button press volume-Display power saving mode the backlight is off or set to a minimum B.2.1.4 CDMA terminal B.2.1.4.1 Network environment

Table B.12 Network Environment Parameter Settings

Set parameter settings value comments the center frequency of the frequency band in which the working frequency band UE works shall indicate the terminal frequency band in the test result.

Band actually used in BAND class0 and BAND class6 Ior -75 dBm -Pilot Ec Ior-7 dB -Paging Ec Ior-12 dB -Quick paging channel 0- not supported -REG_PRD 58 registra...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.

Referenced standards

How to Download HJ 2508-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
12 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

HJ 2508-2011

$444.00