HJ 1109-2020Technical specification for application and issuance of pollutant permit - Farm and sideline food processing industry - Aquatic products processing industry (English PDF)
This is a limited preview
Buy now to download the full PDF (34 pages)
Need quotation for your management?
Get a formal quotation for HJ 1109-2020 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
February 28, 2020
Implementation date
February 28, 2020
Scope
HJ 1109-2020 (Technical specification for application and issuance of pollutant permit - Farm and sideline food processing industry - Aquatic products processing industry) is available as an English-translated PDF.
HJ 1109-2020 — Agricultural and sideline food processing industry-aquatic product processing industry 1 Scope of application this standard stipulates the basic requirements and permits for the application and issuance of pollutant discharge permits for aquatic product processing industries.
Determination of emission limit, actual emission calculation and compliance determination methods, as well as self-monitoring, environmental management accounting and pollution discharge Environmental management requirements such as the permit implementation report put forward reference requirements for feasible technologies for pollution prevention and control in aquatic product processing industries.
This standard is applicable to guide the aquatic product processing industry pollutants to fill in relevant information on the national pollutant discharge permit management information platform the application information is also applicable to guide the issuing authority to review and determine the requirements of the pollutant discharge permit for the aquatic product processing industry.
This standard is applicable to the management of permits for the discharge of air pollutants and water pollutants discharged by pollutants from the aquatic product processing industry.
This standard does not apply to the pollutant discharge units of chemical products such as aquatic products production auxiliaries and additives and pharmaceuticals, and from it is a pollutant discharge unit that manufactures canned aquatic products and uses aquatic products and processing waste as raw materials to produce feed.
Among the aquatic product processing industry pollutants, those that implement the "Emission Standard of Air Pollutants for Thermal Power Plants" (GB 13223) Pollution facilities or discharge outlets are applicable to the "Technical Specifications for Application and Issuance of Pollution Permits for Thermal Power Industry"; Pollution production facilities or discharge outlets in the Pollutant Discharge Standard (GB 13271) are applicable to the "Pollution Discharge Permit Application and Issuance Technology" Specification for Boilers" (HJ 953).
Other pollution-producing facilities and discharge units of aquatic product processing industries that are not specified in this standard but discharge industrial waste water and waste gas to release the mouth, refer to the "General Rules for the Application and Issuance of Pollutant Discharge Permits" (HJ 942).
Found what you need?
Document preview — HJ 1109-2020
National Standard of the People's Republic of China
Issued by: Ministry of Ecology and Environment
Contents
- Foreword
- 1 Scope of application
- 2 Normative references
- 3 Terms and definitions
- 4 Requirements for the declaration of the basic situation of the pollutant discharge unit
- 5 Corresponding discharge outlets in the production and discharge process and methods for determining permitted discharge limits
- 6 Feasible technical requirements for pollution prevention
- 7 Self-monitoring management requirements
- 8 Requirements for preparation of environmental management ledger records and execution reports
- 9 Accounting Method of Actual Emissions
- 10 Compliance Judgment Method
- Appendix A (informative appendix) Reference method for calculating the allowable discharge of wastewater pollutants
- Appendix B (informative appendix) Reference table of feasible technologies for wastewater pollution prevention and control
- Appendix C (Informative Appendix) Reference Table of Available Technologies for Waste Gas Pollution Prevention and Control
- Appendix D (Informative Appendix) Reference Table for Environmental Management Ledger Records
- Appendix E (Normative Appendix) Accounting Method for Actual Wastewater Pollutant Discharge
Foreword
In order to implement the "Environmental Protection Law of the People's Republic of China", "The Air Pollution Prevention Law of the People's Republic of China", "China the Water Pollution Prevention and Control Law of the People's Republic of China, the Soil Pollution Prevention and Control Law of the People's Republic of China and other laws and regulations, and the Office of the State Council Notice on Issuing the Implementation Plan of the Permit System for Controlling Pollutant Discharge (Guobanfa [2016] No. 81), Manageable Measures (for Trial Implementation)" (Ministry of Environmental Protection Order No. 48) to improve the technical support system for pollutant discharge permits, guidance and regulations this standard is formulated for the application and issuance of pollutant discharge permits for the aquatic product processing industry.
This standard stipulates the basic requirements and permits for the application and issuance of pollutant discharge permits for aquatic product processing industries.
Determination of emission limit, actual emission calculation and compliance determination methods, as well as self-monitoring, environmental management accounting and pollution discharge Environmental management requirements such as the permit implementation report put forward reference requirements for feasible technologies for pollution prevention and control in aquatic product processing industries.
Appendix A to Appendix D of this standard are informative appendices, and Appendix E is a normative appendix.
This standard is issued for the first time.
This standard is formulated by the Department of Environmental Impact Assessment and Emission Management and the Department of Regulations and Standards of the Ministry of Ecology and Environment.
The main drafting organizations of this standard. Chinese Academy of Environmental Sciences, Light Industry Environmental Protection Research Institute.
This standard was approved by the Ministry of Ecology and Environment on February 28, 2020.
This standard will be implemented on February 28, 2020.
This standard is interpreted by the Ministry of Ecology and Environment.
1 Technical specifications for pollutant discharge permit application and issuance
Agricultural and sideline food processing industry-aquatic product processing industry
1 Scope of application this standard stipulates the basic requirements and permits for the application and issuance of pollutant discharge permits for aquatic product processing industries.
Determination of emission limit, actual emission calculation and compliance determination methods, as well as self-monitoring, environmental management accounting and pollution discharge Environmental management requirements such as the permit implementation report put forward reference requirements for feasible technologies for pollution prevention and control in aquatic product processing industries.
This standard is applicable to guide the aquatic product processing industry pollutants to fill in relevant information on the national pollutant discharge permit management information platform the application information is also applicable to guide the issuing authority to review and determine the requirements of the pollutant discharge permit for the aquatic product processing industry.
This standard is applicable to the management of permits for the discharge of air pollutants and water pollutants discharged by pollutants from the aquatic product processing industry.
This standard does not apply to the pollutant discharge units of chemical products such as aquatic products production auxiliaries and additives and pharmaceuticals, and from it is a pollutant discharge unit that manufactures canned aquatic products and uses aquatic products and processing waste as raw materials to produce feed.
Among the aquatic product processing industry pollutants, those that implement the "Emission Standard of Air Pollutants for Thermal Power Plants" (GB 13223) Pollution facilities or discharge outlets are applicable to the "Technical Specifications for Application and Issuance of Pollution Permits for Thermal Power Industry";
Pollution production facilities or discharge outlets in the Pollutant Discharge Standard (GB 13271) are applicable to the "Pollution Discharge Permit Application and Issuance Technology" Specification for Boilers" (HJ 953).
Other pollution-producing facilities and discharge units of aquatic product processing industries that are not specified in this standard but discharge industrial waste water and waste gas to release the mouth, refer to the "General Rules for the Application and Issuance of Pollutant Discharge Permits" (HJ 942).
2 Normative references
The content of this standard refers to the following documents or their clauses. For undated references, the effective version is suitable Used in this standard.
GB 8978 Integrated Wastewater Discharge Standard GB 9078 Emission Standard of Air Pollutants for Industrial Furnaces GB 13223 Emission Standard of Air Pollutants for Thermal Power Plants GB 13271 Boiler Air Pollutant Emission Standard GB 14554 Emission Standard of Odor Pollutants GB 16297 Comprehensive Emission Standard of Air Pollutants GB 18483 Oil Fume Emission Standard for Catering Industry (Trial) HJ 91.1 Technical Specification for Wastewater Monitoring HJ 521 Wastewater Discharge Law Code (Trial) HJ 608 Code Rules for Pollutant Discharge Units HJ 860.2 Pollutant Discharge Permit Application and Issuance Technical Specification Agricultural and Sideline Food Processing Industry-Starch Industry HJ 942 General Rules of Technical Specifications for Pollution Discharge Permit Application and Issuance 2HJ 944 General Rules of Technical Specifications for Environmental Management Ledgers and Pollution Discharge Permit Implementation Report of Pollutant Discharge Units (Trial) HJ 953 Sewage discharge permit application and issuance of technical specifications for boilers HJ 986 Technical Guide for Self-monitoring of Pollutant Discharge Units Agricultural and Sideline Food Processing Industry "List of Classification Management of Discharge Permits for Fixed Pollution Sources" "Administrative Measures for Pollution Discharge Permits (Trial)" (Ministry of Environmental Protection Order No. 48) "Technical Requirements for Standardized Remediation of Sewage Outlets (Trial)" (Environmental Supervision [1996] No. 470) "Announcement on the Implementation of Special Emission Limits for Air Pollutants" (Announcement No. 14 of 2013 by the Ministry of Environmental Protection) "Reply to Issues Concerning the Implementation of Special Emission Limits for Air Pollutants" (Huanban Qiqihan [2016] No. 1087) "Announcement on the Implementation of Special Emission Limits for Air Pollutants in Beijing-Tianjin-Hebei Air Pollution Transmission Channel Cities" (Environmental Protection Ministry Announcement No. 9 of 2018)
3 Terms and definitions
The following terms and definitions apply to this standard.
Pollutant emission unit of aquatic products processing industry Refers to using aquatic animals and plants as raw materials to process and produce frozen aquatic products, surimi and fish through physical, chemical or biological methods.
Sewage discharge units for processed aquatic products such as surimi products, dry pickled products, seaweed processed products, and fish oil products.
Permitted emission limits Refers to the maximum discharge concentration (rate) and discharge volume of pollutants that are allowed to be discharged by the pollutant discharge unit specified in the pollution discharge permit.
Special periods
Refers to the environmental quality compliance plan formulated by the local people's government according to law or other relevant environmental management regulations, the pollutant discharge of pollutants has special requirements for the time period, including the response period of heavy pollution weather and the winter prevention period.
Production period
Refers to the period of time from the start of production to the end of each production season of aquatic product processing industry pollutants, calculated on a daily basis.
4 Requirements for the declaration of the basic situation of the pollutant discharge unit
4.1 Basic principles
The aquatic product processing industry pollutant discharge unit shall, in accordance with the requirements of this standard, register in the national pollutant discharge permit management information platform application system Fill in the corresponding information form. Those not included in the reporting system, the local ecological If you need to fill in, you can add content by yourself.
Local ecological and environmental authorities at or above the level of a city divided into districts may, in accordance with local
3 The content specified in the pollution discharge permit, and fill in the "places with the right to issue approval" in the application system of the national pollution discharge permit management information platform the management content added by the competent department of ecological environment of the Party.
4.2 Basic information of pollutants
The basic information of the sewage disposal unit of the aquatic product processing industry should be filled with the name of the unit, whether it needs to be rectified, the management category of the pollution permit Postal code, industry category (select "agricultural and sideline food processing industry-aquatic product processing industry" when filling in), whether to put into production, put into production Date, latitude and longitude of the center of the production and operation site, whether the location is an environmentally sensitive area (such as total phosphorus and total nitrogen control area, etc.), yes Whether it is located in an industrial park, the name of the industrial park to which it belongs, the approval document number (record number) of the environmental impact assessment document for the construction project, the identification or filing document number of the local government on the illegal project, the document number of the main pollutant total distribution plan, chemical oxygen demand Total quantity index (t/a), total ammonia nitrogen index (t/a), total quantity index of other pollutants involved, etc.
4.3 Main products and production capacity
4.3.1 General principles
The name of the main production unit, main process name, production facility name, production facility number, facility parameters, Product name, production capacity, unit of measurement, design year production time and others. The following "4.3.2-4.3.6" is required, "4.3.7" it is optional.
4.3.2 Names of main production units, main processes and production facilities
The main production units, main processes, production facilities and facility parameters of the aquatic product processing industry pollutants are shown in the table 1.Refer to Table 1 for the production of other products in the aquatic product processing industry. The pollutant discharge unit needs to fill in the production unit other than report 1, for the production process and production facilities, you can select the "other" item in the declaration system to fill in.
4.3.3 Production facility number
The aquatic product processing industry pollutant discharge unit shall fill in the internal production facility number or number and fill in according to HJ 608.
4.3.4 Product name
Including frozen aquatic products, surimi and surimi products, dried aquatic products, processed seaweed products, fish oil products, other he.
4.3.5 Production capacity and measurement unit
The production capacity is the design capacity of the main product, excluding the production capacity that the national or local 5 can. If there is no design capacity data, it is calculated based on the average actual output of the past three years. The unit of measurement for production capacity is t/a.
4.3.6 Design year production time
According to the environmental impact assessment documents and their approval, review opinions or in accordance with relevant national regulations Fill in the annual production time in the relevant certification materials that meet the requirements of the management and rectification. If there is no relevant document or Specify the production time and fill in the actual production time.
4.3.7 Other
If the aquatic product processing industry pollutant discharge unit has content that needs to be explained, it can be filled in.
4.4 Main raw and auxiliary materials and fuels
4.4.1 General principles
The main raw and auxiliary materials should be filled with the type of raw and auxiliary materials, the designed annual usage and the unit of measurement; the fuel composition, including ash, Sulfur, volatile matter, moisture, calorific value; others. The following "4.4.2-4.4.4" are required items, and "4.4.5" are optional items.
4.4.2 Types of raw and auxiliary materials and fuels
The types of raw materials include fish, shrimp, crustaceans, shellfish, algae and other aquatic animals or plants, and others.
The types of auxiliary materials include water, salt, soy sauce and other seasonings, degreasing solvents, animal and vegetable oils, food additives, containers, Packing box/bag, cleaning agent, preservative, sewage treatment dosing agent, etc.
Fuel types include coal, heavy oil, diesel, natural gas, biogas, and others.
4.4.3 Designed annual usage and unit of measurement
The designed annual consumption is the annual consumption of raw and auxiliary materials and fuels that match the production capacity.
The unit of measurement for the designed annual consumption is t/a or Nm3/a.
4.4.4 Fuel ash, sulfur, volatile and calorific value
Fill in the fuel ash, sulfur, volatile and calorific value (low calorific value) according to the design value or the actual production value of the previous year.
Fill in sulfur content for fuel oil and gas (liquid fuel is calculated as sulfur content; gas fuel is calculated as total sulfur, and total sulfur includes organic sulfur and inorganic sulfur) and calorific value (low calorific value). The reported value of solid fuel and liquid fuel is based on the received basis.
4.4.5 Other
Other content that needs to be explained by the sewage disposal unit of the aquatic product processing industry can be filled in.
4.5 Production and discharge nodes, pollutants and pollution prevention facilities
4.5.1 Wastewater
4.5.1.1 General principles
The type of wastewater, pollutant type, discharge destination, discharge pattern, pollution prevention facilities, and whether it is a feasible technology should be reported.
Whether the technology, discharge port number, discharge port settings meet the requirements, and discharge port type. The following "4.5.1.2-4.5.1.6" is required.
64.5.1.2 Wastewater categories, pollutant items and pollution prevention facilities
Fill in the category, pollutant type, discharge destination, and pollution prevention facilities See Table 2 for the content. The types of pollutants discharged by the aquatic product processing industry are determined in accordance with GB 8978.Food processing industry After the water pollutant discharge standard is issued, the pollutant discharge unit or production facility within its applicable scope shall comply with its regulations. Place more strict the emission standards shall be strictly determined in accordance with local emission standards.
4.5.1.3 Emission destination and emission law the aquatic product processing industry pollutant discharge unit shall clarify the destination and discharge rules of wastewater discharge.
The discharge destination is divided into no discharge; directly into the water environment of rivers, lakes, reservoirs, etc.; directly into the sea; into the urban water Road (re-entering rivers, lakes, reservoirs); entering urban sewers (re-entering coastal waters); entering urban sewage treatment facilities;
Enter other units; enter other centralized industrial wastewater treatment facilities; others.
Fill in the discharge rule when the wastewater enters the environmental water body directly or indirectly, and do not need to fill it when it is not discharged. Wastewater discharge law class Don't see HJ 521.
4.5.1.4 Number of pollution prevention facilities and discharge outlets the number of pollution prevention facilities can be filled in with the internal number of the pollutant discharge unit or according to HJ 608 and filled in.
Fill in the existing number of the local ecological environment authority for the wastewater discharge port number. If there is no serial number, follow HJ 608 Number and fill in.
The number of the rainwater discharge outlet can be filled in the internal number of the sewage discharge unit, or use "YS three-digit serial number" (such as YS001) Number and fill in.
4.5.1.5 Requirements for discharge port setting According to "Technical Requirements for Standardized Remediation of Sewage Outlets (Trial)", relevant local management requirements, and aquatic product processing workers the regulations on the standardized setting of discharge outlets in the discharge standards implemented by the industrial pollutant discharge unit, report whether the setting of wastewater discharge outlets meets the Standardization requirements.
4.5.1.6 Type of discharge port the main waste water discharge outlets (discharge outlets of integrated sewage treatment stations) of the aquatic product processing industries that implement key management to discharge outlets, a separate direct discharge outlet for domestic sewage is a general discharge outlet. Simplified management of sewage from aquatic product processing industry the total discharge outlet of unit wastewater and the direct discharge outlet of separate domestic sewage are general discharge outlets. Separately discharged to the public sewage treatment system the domestic sewage only shows the discharge destination.
4.5.2 Exhaust gas
4.5.2.1 General principles the name of the corresponding pollution production link, the type of pollutant, the form of discharge (organized or unorganized), pollution prevention facilities, Whether it is a feasible technology, organized discharge port number, whether discharge port setting meets the requirements, discharge port type, and the remaining items are related the system is automatically generated. The following "4.5.2.2-4.5.2.5" is required.
4.5.2.2 Names of waste gas pollution generation links, types of pollutants, emission forms and pollution prevention facilities the waste gas production links, types of pollutants, emission forms and pollution prevention facilities of the aquatic product processing industries See Table 3.The types of pollutants discharged by the aquatic product processing industry are based on GB 9078, GB 14554, GB 16297, GB 18483 determine. Where local regulations have stricter emission standards, follow their regulations.
4.5.2.3 Number of pollution prevention facilities and organized discharge outlets the number of pollution prevention facilities can be filled in with the internal number of the pollutant discharge unit or according to HJ 608 and filled in.
The organized discharge port number fill in the existing number of the local ecological environment authority. If there is no serial number, enter according to HJ 608 Line number and fill in.
4.5.2.4 Standardized setting of discharge ports According to "Technical Requirements for Standardized Remediation of Sewage Outlets (Trial)", relevant local management requirements, and aquatic product processing workers the regulations on the standardized setting of discharge outlets in the discharge standards implemented by the industrial pollutant discharge unit, report whether the setting of exhaust gas discharge outlets meets the Standardization requirements.
4.5.2.5 Type of discharge port all waste gas discharge outlets of the aquatic product processing industry are general discharge outlets.
4.6 Drawing requirements the basic situation of aquatic product processing industry pollutants should also include the production process flow chart (including the whole plant and various procedures) and the plant District general layout plan, rainwater and sewage pipe network layout plan.
The production process flow chart should at least include the main production facilities (equipment), the flow of main materials, the production process and Production and discharge nodes and other content.
The general layout of the plant area should include the main facilities, public and auxiliary facilities, sewage treatment facilities, etc., and indicate the plant area Lost routes, etc.
The layout drawing of rainwater and sewage pipe network should include the direction of rainwater and sewage collection and transportation pipelines in the plant area, the location of discharge outlets and the discharge destination.
To wait for content.
5 Corresponding discharge outlets in production and discharge links and methods for determining permitted discharge limits
5.1 Discharge outlets and implementation standards
5.1.1 Wastewater discharge outlets and implementation standards for direct wastewater discharge outlets, the geographical coordinates of the discharge outlets, the name and code of the corresponding sewage outlets into the river, and the information of receiving natural water bodies should be filled in.
Information, the geographic coordinates of the receiving natural water body and the implementation of national or local pollutant discharge standards; indirect wastewater discharge outlets the geographic coordinates of the discharge outlet, the information of the receiving sewage treatment plant and the implementation of the national or local pollutant discharge standards shall be filled in, and the discharge shall be made separately.
The domestic sewage that enters the public sewage treatment system only shows whereabouts. Where wastewater is discharged intermittently, the time when pollutants are discharged shall be stated segment. Where wastewater is discharged into the ocean, shore discharge or deep-sea discharge shall also be stated. For deep-sea discharge, the depth of the sewage outlet should also be stated Degree, the straight-line distance from the shoreline.
5.1.2 Exhaust gas discharge ports and implementation standards Exhaust gas outlets should be filled with the geographical coordinates of the outlet, the height of the exhaust tube, the inner diameter of the exhaust tube outlet, and national or local pollutants Emission standards, environmental impact assessment document approval, review opinions and commitments to stricter emission limits.
5.2 Permissible emission limits
5.2.1 General principles the permitted emission limit includes the permitted emission concentration of pollutants and the permitted emission volume. Permitted emissions include annual allowable emissions and Allowable ...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 34 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 8978Integrated wastewater discharge standard
- GB 13223Emission standard of air pollutants for thermal power plants
- GB 13271Emission standard of air pollutants for boiler
- GB 14554Emission standards for odor pollutants
- GB 16297Integrated emission standard of air pollutants
- GB 18483Emission standard of cooking fume
GB 9078
How to Download HJ 1109-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.