HG/T 5763-2020Determination of metal elements in metallocene polyolefin catalysts - Inductively coupled plasma optical emission spectrometry (English PDF)
茂金属聚烯烃催化剂中金属元素的测定 电感耦合等离子体发射光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for HG/T 5763-2020 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
December 9, 2020
Implementation date
April 1, 2021
Scope
HG/T 5763-2020 is the English-translated version of 茂金属聚烯烃催化剂中金属元素的测定 电感耦合等离子体发射光谱法.
HG/T 5763-2020 is the recommended Chinese chemical industry standard giving the inductively coupled plasma optical emission spectrometry method for metal elements in metallocene polyolefin catalysts.
It describes how magnesium, titanium, calcium, zirconium and further elements are determined with an ICP emission spectrometer.
It applies to metallocene polyethylene and metallocene polypropylene catalysts within the ranges 100.00 mg/kg to 220.00 mg/kg for magnesium, 45.00 mg/kg to 165.00 mg/kg for titanium, 210.00 mg/kg to 570.00 mg/kg for calcium and 1600.00 mg/kg to 2600.00 mg/kg for zirconium; samples outside these ranges may also be measured, but the precision has not been verified for them.
GB/T 602, GB/T 6379.2, GB/T 6682 and GB/T 8170 are quoted with it. Issued on 9 December 2020, it has applied since 1 April 2021.
Found what you need?
Document preview — HG/T 5763-2020
National Standard of the People's Republic of China
- ICS
- 71.100.99
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- [Preview only]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Molecular formula and relative molecular mass
- 5 Classification
- 6 Test methods
- 6.1 General provisions
- 6.2 Appearance inspection
- 7 Inspection rules
- 9 Marking and accompanying documents
1 Foreword
HG/T 5763-2020 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 9 December 2020 and has been in force since 1 April 2021.
The HG/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
The document runs to 15 pages in English translation.
2 Scope Preview
This standard is the recommended Chinese chemical industry standard giving the inductively coupled plasma optical emission spectrometry method for metal elements in metallocene polyolefin catalysts. It describes how magnesium, titanium, calcium, zirconium and further elements are determined with an ICP emission spectrometer. It applies to metallocene polyethylene and metallocene polypropylene catalysts within the ranges 100.00 mg/kg to 220.00 mg/kg for magnesium, 45.00 mg/kg to 165.00 mg/kg for titanium, 210.00 mg/kg to 570.00 mg/kg for calcium and 1600.00 mg/kg to 2600.00 mg/kg for zirconium; samples outside these ranges may also be measured, but the precision has not been verified for them. GB/T 602, GB/T 6379.2, GB/T 6682 and GB/T 8170 are quoted with it.
HG/T 5763-2020 falls under ICS 71.100.99, in the field of chemical technology.
This catalogue holds 1,628 other HG/T standards in that field.
In this catalogue, HG/T standards carry edition years from 1975 to 2026.
3 Normative references
GB/T 602
GB/T 6379.2
GB/T 6682
GB/T 8170
4 About this standard
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
English translation: about 15 pages
5 Related standards
Standards on related subjects:
GB/T 37354-2019 — Analytical method of chemical composition for activated carbon mercury removal catalyst
GB/T 34248-2017 — Performance test method of three-way catalyst
HG/T 2976-2011 — Fertilizer catalysts - Determination of attrition rate
HG/T 5769-2021 — Determination method of copper in spent copper-based catalysts
HG/T 5757-2020 — Methods for chemical composition analysis of aluminium-based hydrogenation catalysts
HG/T 5756-2020 — Methods for chemical composition analysis of catalysts for selective hydrogenation of benzene to cyclohexene
6 Classification and status
International classification (ICS): 71.100.99
Prefix HG/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 602Chemical reagent - Preparation of standard solutions for impurity determination
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
Similar standards
GB/T 37248-2018|HG/T 6054-2022|GB/T 43310-2023|NB/SH/T 0864-2023|GB/T 6730.76-2017|GB/T 43574-2023
How to Download HG/T 5763-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 602-1988 — Chemical reagent--Preparations of stock standard solutions
GB/T 602-2002 — Chemical reagent - Preparations of standard solutions for impurity
GB/T 602-2026 — Chemical reagent - Preparation of standard solutions for impurity determination
HG/T 5763-2020
$135.00