GB/Z 6113.403-2020Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products (English PDF)
Also coversGBZ6113.403-2020
Open the GB/Z 6113.403-2020 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB/Z 6113.403-2020 (Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-3: Uncertainties, statistics and limit modelling - Statistical considerations in the determination of EMC compliance of mass-produced products) is available as an English-translated PDF.
GB/Z 6113.403-2020 — This part of GB/T 6113 describes statistical considerations for determining the electromagnetic compatibility (EMC) compliance of bulk products. Reasons for this statistical consideration. a) The purpose of reducing interference is to make most qualified products not cause interference; b) The International Special Committee on Radio Interference (CISPR) limit must not only be suitable for the type approval of a single product, but also suitable for batch Type approval of the product; c) Statistical techniques need to be applied to ensure that batch products meet CISPR limits; d) Every country should have the same understanding of the meaning of these limits, which is very important for international trade; e) The national committees of IEC participating in CISPR cooperation shall strive to seek the recognition of the country where they are located. Therefore, this section specifies requirements and provides guidance based on statistical techniques. The EMC compliance of bulk products needs to be based on statistical techniques For applications, this technology should assure consumers that 80% of the products of the researched type meet the emission or immunity requirements with 80% confidence. Chapter 4 gives the general requirements of the 80%/80% criterion. Chapter 5 gives more specific aspects of the 80%/80% criterion applied to launch tests. Claim. Chapter 6 gives guidelines for the application of CISPR 80%/80% criteria to immunity tests. 80%/80% guidelines protect consumers from Products that do not meet the limit requirements will be obtained, but this does not represent the probability of acceptance of a sampled batch of products. But the probability of acceptance Is very important. Appendix A gives more information about the probability of acceptance (manufacturer's risk).
Document preview — GB/Z 6113.403-2020
National Standard of the People's Republic of China
- ICS
- 33.100.20
- Classification
- L 06
- Replacing
- GB/Z 6113.403-2007
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms, definitions and symbols1
- 4 General requirements1
- 4.1 Limit2
- 4.2 Type test method2
- 5 Emission measurement2
Foreword
GB/T 6113 "Specifications for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods" is the basic electromagnetic compatibility standard, which consists of the following four parts.
Part 1.Radio disturbance and immunity measurement equipment
---Part 1-1.Radio disturbance and immunity measuring equipment measuring equipment;
---Part 1-2.Coupling device for conducting disturbance measurement of radio disturbance and immunity measuring equipment;
---Part 1-3.Radio disturbance and immunity measuring equipment auxiliary equipment disturbance power;
---Part 1-4.Antennas and test sites for radio disturbance and immunity measurement equipment radiation disturbance measurement;
---Part 1-5.Radio disturbance and immunity measurement equipment 5MHz~18GHz antenna calibration site and reference test site;
---Part 1-6.Radio disturbance and immunity measurement equipment EMC antenna calibration.
Part 2.Radio disturbance and immunity measurement methods
---Part 2-1.Radio disturbance and immunity measurement method conducted disturbance measurement;
---Part 2-2.Radio disturbance and immunity measurement method disturbance power measurement;
---Part 2-3.Radio disturbance and immunity measurement method Radiated disturbance measurement;
---Part 2-4.Radio disturbance and immunity measurement methods, immunity measurement;
---Part 2-5.Field measurement of large-scale equipment disturbance launch.
Part 3.Radio disturbance and immunity measurement technical report
---Part 3.Radio disturbance and immunity measurement technical report.
Part 4.Uncertainty, Statistics and Limit Modeling
---Part 4-1.Uncertainty of uncertainty, statistics and limit modeling standardized EMC test;
---Part 4-2.Uncertainty, statistics and limit modelling uncertainty of measuring equipment and facilities;
---Part 4-3.Statistical considerations for the determination of EMC compliance of batch products in uncertainty, statistics and limit modeling;
---Part 4-4.Uncertainty, statistics and limit modeling complaint statistics and limit calculation model;
---Part 4-5.Uncertainty, statistics and limit modeling alternative test method use conditions.
This part is part 4-3 of GB/T 6113.
This section was drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB /Z 6113.403-2007 "Radio disturbance and immunity measurement equipment and measurement method specification Part 4-3.
Uncertainty, Statistics, and Limit Modeling Statistical Considerations for the Determination of EMC Conformity of Batch Products", and GB /Z 6113.403-2007
In comparison, the main technical changes are as follows.
---Modified the normative reference documents (see Chapter 2, Chapter 2 of the.2007 edition);
---Added the estimation of sample acceptance probability (see Appendix D).
The translation method used in this part is equivalent to the adoption of CISPR16-4-3/TR.2007 "Regulations for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods"
Part 4-3.Uncertainty, Statistics and Limit Modeling. Statistical Considerations for the Determination of EMC Conformity of Batch Products."
The Chinese documents that have a consistent correspondence with the international documents cited in this section are as follows.
---GB/T 6113.402-2018 Radio disturbance and immunity measurement equipment and measurement method specification Part 4-2.Uncertainty
Degree, Statistics and Limit Modeling Uncertainty of Measuring Equipment and Facilities (CISPR16-4-2.2014, IDT)
This section has made the following editorial changes.
---In order to facilitate the quotation in the text, the table number and header have been added to some tables (see Table 1, Table 2, Table A.1, Table A.2 and Table A.3).
---Added reference CISPR/T R16-4-1.
This part is proposed and managed by the National Radio Interference Standardization Technical Committee (SAC/TC79).
Drafting organizations of this section. China Electronics Standardization Institute, China Automotive Engineering Research Institute Co., Ltd., Industry and Information Technology
The Fifth Institute of Electronics, Beijing Jiaotong University, China Institute of Metrology, Southeast University, Xi'an Satellite Measurement and Control Center, Ningbo Customs Technology
Center, China Automobile Research Institute Automobile Inspection Center (Tianjin) Co., Ltd., Jiangsu Institute of Metrology, Weikai Testing Technology Co., Ltd., Xiamen City
Quality Supervision and Inspection Institute, China Household Electrical Appliances Research Institute, National Radio Monitoring Center, Shanghai Electrical Apparatus Research Institute (Group) Co., Ltd.
1 Scope
This part of GB/T 6113 describes statistical considerations for determining the electromagnetic compatibility (EMC) compliance of bulk products.
Reasons for this statistical consideration.
a) The purpose of reducing interference is to make most qualified products not cause interference;
b) The International Special Committee on Radio Interference (CISPR) limit must not only be suitable for the type approval of a single product, but also suitable for batch
Type approval of the product;
c) Statistical techniques need to be applied to ensure that batch products meet CISPR limits;
d) Every country should have the same understanding of the meaning of these limits, which is very important for international trade;
e) The national committees of IEC participating in CISPR cooperation shall strive to seek the recognition of the country where they are located.
Therefore, this section specifies requirements and provides guidance based on statistical techniques. The EMC compliance of bulk products needs to be based on statistical techniques
For applications, this technology should assure consumers that 80% of the products of the researched type meet the emission or immunity requirements with 80% confidence.
Chapter 4 gives the general requirements of the 80%/80% criterion. Chapter 5 gives more specific aspects of the 80%/80% criterion applied to launch tests.
Claim. Chapter 6 gives guidelines for the application of CISPR 80%/80% criteria to immunity tests. 80%/80% guidelines protect consumers from
Products that do not meet the limit requirements will be obtained, but this does not represent the probability of acceptance of a sampled batch of products. But the probability of acceptance
Is very important. Appendix A gives more information about the probability of acceptance (manufacturer's risk).
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 4365-2003 Electrotechnical terminology electromagnetic compatibility
CISPR16-4-2 Specification for Radio Disturbance and Immunity Measurement Equipment and Measurement Methods Part 4-2.Uncertainty, Statistics and
Limit modelling the uncertainty of measuring equipment and facilities
3 Terms, definitions and symbols
The terms, definitions and symbols defined in GB/T 4365-2003 apply to this document.
4 General requirements
The following explains the CISPR limit and the statistical sampling method to make batch products comply with the limit.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 4365-2003
How to Buy GB/Z 6113.403-2020
- 1Add to cart. Click the "Buy GB/Z 6113.403-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 6113.3-2019 — Specification for radio disturbance and immunity measuring apparatus and methods -- Part 3: CISPR technical reports
GB/Z 6113.401-2018 — Specification for radio disturbance and immunity measuring apparatus and methods -- Part 4-1: Uncertainties, statistics and limit modelling -- Uncertainties in standardized EMC tests
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems
Secure payment via Stripe
Payments accepted
GB/Z 6113.403-2020