GB/Z 44387-2024Fine bubble technology - Measurement techniques for the characterization of fine bubbles (English PDF)
微细气泡技术 微细气泡特性测量技术
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/Z 44387-2024 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 23, 2024
Implementation date
August 23, 2024
Scope
GB/Z 44387-2024 is the English-translated version of 微细气泡技术 微细气泡特性测量技术.
GB/Z 44387-2024 is a Chinese guidance document, modified from ISO/TR 23015:2020, that reviews measurement techniques for characterizing fine bubbles.
It compares how bubble size, size distribution and concentration are obtained by dynamic light scattering, zeta potential measurement, particle tracking analysis, laser diffraction, resonant mass measurement, the electrical sensing zone method, ultrasonic attenuation spectroscopy, single particle optical methods, static and dynamic image analysis and static multiple light scattering.
For each technique it outlines the principle together with its advantages and limitations. It also warns that fine bubble dispersions change over time and often contain solid particles that some instruments cannot tell apart from bubbles. It was issued on 23 August 2024.
Found what you need?
Document preview — GB/Z 44387-2024
National Standard of the People's Republic of China
- ICS
- 19.120
- Classification
- A 28
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Characterization of microbubbles
- 5.1 Overview
- 5.2 Comparison of bubble size and concentration measured by different techniques
- 6 Characterization techniques
- 6.1 Overview
- 6.2 Dynamic light scattering
- 6.3 Zeta potential measurement method (electrophoretic migration)
- 6.4 Particle Tracking Analysis
- 6.5 Laser diffraction method
- 6.6 Resonance mass measurement method
- 6.7 Resistance method
- 6.8 Ultrasonic Attenuation Spectroscopy
- 6.9 Optical Measurement Methods for Single Particles
- 6.10 Static Image Analysis
- 6.11 Dynamic Image Analysis
- 6.12 Static Multiple Light Scattering (SMLS)
- References
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting is required.
This document is modified to adopt ISO /TR 23015:2020 "Microbubble technology Microbubble characterization measurement technology matrix", file type The ISO technical report was adjusted to become my country's national standardization guiding technical document.
Compared with ISO /TR 23015:2020, this document has the following structural adjustments.
The first paragraph of Chapter 6 is adjusted to 6.1, and the subsequent numbers are postponed accordingly. - The technical differences between this document and ISO /TR 23015:2020 and their reasons are as follows.
The parameter "concentration" in 5.1 is explained as "or the volume fraction of the gas in the mixture" to improve operability. - The following editorial changes were made to this document.
The name of the standard is changed to "Microbubble Technology" Microbubble Characteristics Measurement Technology; - Correct the abbreviation of Ultrasonic Attenuation Spectroscopy to UAS; - Change the evaluation target parameter in 5.1 and "number concentration" in Table 1 to "concentration"; - GB/T 29022, which is referenced as an informative document, replaces ISO 22412 (see Table 1, 6.2.2).
GB/T 32671.2 replaces ISO 13099-2 (see Table 1, 6.3.2), and replaces GB/T 42348 with the informative reference
ISO 19430 (see Table 1, 6.4.1, 6.4.2 and 6.4.5), replaces GB/T 19077 with the informative reference
ISO 13320 (see Table 1 and 6.5.2) replaces ISO 13319 (see Table 1 and 6.7.2), replace ISO 20998-1 with the informative reference GB/T 29023.1 (see Table 1, 6.8.1 and 6.8.2), replace ISO 20998-1 with the informative reference GB/T 29023.1
GB/T 29024.2 replaces ISO 21501-2 (see Table 1 and 6.9.2), and replaces GB/T 29024.3 with the informative reference
ISO 21501-3 (see Table 1 and 6.9.2), replaces ISO 13322-1 (see Table 1 and 6.10.2), replace ISO 13322-2 with the informative reference GB/T 21649.2 (see Table 1 and 6.11.1);
Moved the "typical flow rate is 0.2 nL/s" of the measurement time of the resonance mass measurement method in Table 1 to the footnote of Table 1; - Correct the bubble particle size of the resistance method in Table 1 and the particle size in 6.7.3 to "50 nm to 1 600 µm"; - The bubble particle size of the static image analysis method, the bubble particle size of the dynamic image analysis method, the particle size of 6.10.3 and the particle size of 6.11.2 in Table 1 are Corrected to " >0.5 µm";
Change "under revision" in Table 1 of the static multiple light scattering method standard to "ISO /TS 21357"; - Correct the bubble particle size of the static multiple light scattering method in Table 1 and the particle size in 6.12.3 to "10 nm to 1 mm"; - Replace ISO 22412:2017 with the informative reference GB/T 29022-2021 (see 6.2.1, 6.2.6, 6.4.6); - Deleted the reference standard ASTM E2834 in 6.4.2; - 6.8.4 Added Note: - Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents.
Introduction
Microbubble technology is widely used in cleaning, transportation, maintenance, agriculture, forestry, animal husbandry and fishery, food and beverage, cosmetics and biomedicine industries.
The detection, characterization and quantitative description of the properties of microbubble mixtures are crucial to the development of microbubble technology, a common technology in multiple industries.
Many of the techniques used to detect and characterize particles can also be used to characterize mixtures of fine bubbles in solution. However, some of these techniques may require Special sample handling, sample preparation or instrument setup are required to obtain quantitative and reliable results.
This paper lists some techniques and discusses their applicability and limitations for characterizing fine bubble mixtures.
It can exist in opaque liquids or high-viscosity liquids. When the number of bubbles is large, the sample solution containing tiny bubbles will become turbid.
All fine bubble solutions are inherently dynamic, with their properties changing over time. For this reason, each technique (measuring The accuracy of the results is closely related to the sampling time. Most micro-bubble sample solutions contain both bubbles and solid particles.
1 Scope
This document describes the most commonly used microbubble preparation and characterization techniques and their interpretation, and outlines the advantages and limitations of each technique.
This document applies to the measurement of bubble size, bubble size distribution and bubble concentration in the field of micro-bubble technology.
2 Normative references
This document has no normative references.
3 Terms and definitions
There are no terms or definitions that require definition in this document.
The terminology bases maintained by ISO and IEC for standardization are as follows. […]
4 Abbreviations
The following abbreviations apply to this document.
CCD. Charge coupled device
DLS. dynamic light scattering
EZ. Electrical sensing zone method
LD. laser diffraction methods
PTA. particle tracking analysis method
RMM. resonance mass measurement
SPOS. single particle light interaction methods
SMLS. static multiple light scattering
UAS. Ultrasonic attenuation spectroscopy
ZP. methods for Zeta potential determination
5 Characterization of microbubbles
5.1 Overview
There are many common particle counting and particle size measurement techniques, some of which are suitable for characterizing fine bubble dispersions.
Dispersions can be present in a variety of liquids, some of which may be opaque (such as printer ink) or unstable (such as flammable fuels).
This paper lists some commercially available technologies and analyses their applicability and limitations. The evaluation target parameters are as follows.
Bubble Size. Usually refers to the equivalent hydrodynamic size, but may vary depending on the measurement technique. - Bubble size distribution. In this document, it refers to the number distribution of particle sizes (or other equivalent distribution). -
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/Z 44387-2024
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 102.17-2026 — Semiconductor devices - Discrete devices - Part 17: Magnetic and capacitive coupler for basic and reinforced insulation
GB/Z 103-2026 — Health informatics - The architecture of internet healthcare service network
GB/Z 108-2026 — Health informatics - Internet healthcare service pattern
GB/Z 44387-2024