Valid

GB/Z 30556.3-2017Electromagnetic compatibility -- Installation and mitigation guidelines -- HEMP protection concepts (English PDF)

Also coversGBZ30556.3-2017

Open the GB/Z 30556.3-2017 preview as PDF

Preview — first pages of GB/Z 30556.3-2017

This is a limited preview

Buy now to download the full PDF

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

September 29, 2017

Implementation date

April 1, 2018

Scope

GB/Z 30556.3-2017 (Electromagnetic compatibility -- Installation and mitigation guidelines -- HEMP protection concepts) is available as an English-translated PDF.

GB/Z 30556.3-2017 — This part of GB /Z 30556 defines the concept of protection of electromagnetic pulses generated by high-altitude nuclear explosion (hereinafter referred to as HEMP) and gives Related information. The purpose of this section is to provide some groundwork for the following areas. --- Civil Facilities HEMP adequate protection design; --- The existing protection against the HEMP strength assessment; --- Comparison of HEMP protection and lightning protection requirements, the purpose is to show whether they can low-cost combination; --- Emphasized the difference between HEMP protection and lightning protection requirements, the purpose is to assess when there is no additional lightning protection Protective measures HEMP results.

Document preview — GB/Z 30556.3-2017

National Standard of the People's Republic of China

ICS
33.100.01
Classification
L 06

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references

Foreword

The Electromagnetic Compatibility Installation and Mitigation Guidelines are divided into the following sections.

--- GB/T 30556.7-2014 Electromagnetic compatibility installation and mitigation guidelines Enclosure electromagnetic disturbance protection class (EM code).

This section GB /Z 30556 Part 3.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This section uses the translation method identical with IEC /T R61000-5-3.1999 "Electromagnetic Compatibility Installation and Mitigation Guidelines Part 5-3.

High-altitude nuclear electromagnetic pulse (HEMP) protection concept. "

The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.

High pressure test techniques - Part 2. Measuring system (IEC 60060-2.1994, IDT);

--- GB/T 17626.24-2012 electromagnetic compatibility test and measurement techniques HEMP conduction disturbance protection test methods

(IEC 61000-4-24.1997);

--- GB/T 18039.8-2012 Electromagnetic compatibility environment High altitude nuclear electromagnetic pulse (HEMP) Environmental Description Conducted Harassment

(IEC 61000-2-10.1998, IDT);

--- YD/T 2191.4-2012 Telecommunication equipment installation and mitigation measures EMC - Part 4. High altitude electromagnetic pulse

(HEMP) Immunity Technical Requirements for Overhead Electromagnetic Pulse Radiated Interference Protection Devices (IEC /T R61000-5-4.1996,

MOD).

This part of the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246) and focal point.

This part of the drafting unit. Ministry of Industry and Information Technology Institute of Electronics Industry Standardization.

1 Scope

This part of GB /Z 30556 defines the concept of protection of electromagnetic pulses generated by high-altitude nuclear explosion (hereinafter referred to as HEMP) and gives

Related information.

The purpose of this section is to provide some groundwork for the following areas.

--- Civil Facilities HEMP adequate protection design;

--- The existing protection against the HEMP strength assessment;

--- Comparison of HEMP protection and lightning protection requirements, the purpose is to show whether they can low-cost combination;

--- Emphasized the difference between HEMP protection and lightning protection requirements, the purpose is to assess when there is no additional lightning protection

Protective measures HEMP results.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility [IEC 60050 (161) .1990, IDT]

Electromagnetic compatibility (EMC) test and measurement techniques Surge (immunity) immunity test (IEC 61000-4-5).

2005, IDT)

GB/T 19271.1-2003 lightning electromagnetic pulse protection Part 1. General (IEC 61312-1.1995, IDT)

High voltage test techniques - Part 2. Measurement systems (High - voltagetesttechniques - Part 2.

Measuringsystems

Surge arresters - Part 1. Surge arresters for AC systems -

Part 1.Non-linearresistortypegappedsurgearrestersfora.c.systems)

IEC 61000-2-9.1996 Electromagnetic compatibility (EMC) part 2-9. Environment HEMP environment Description Radiation Harassment (Elec-

tromagneticcompatibility (EMC) -Part 2.Environment-Section9.DescriptionofHEMPenviron-

ment-Radiated disturbance

IEC 61000-2-10.1998 Electromagnetic compatibility (EMC) part 2-10. Environment HEMP environment Description Conducted disturbance

(Electromagneticcompatibility (EMC) -Part 2-10.Environment-DescriptionofHEMPenviron-

ment-Conducteddisturbance

IEC 61000-2-11, Electromagnetic compatibility (EMC), part 2-11 Environmental HEMP Environmental Description HEMP Environmental Classification

(Electromagneticcompatibility (EMC) -Part 2-11.Environment-DescriptionofHEMPenviron-

ment-Classification of HEMPenvironments)

IEC 61000-4-23, Electromagnetic compatibility testing and measurement techniques - Test methods for devices protecting HEMP and other radiated disturbances

(Electromagneticcompatibility (EMC) -Part 4-23.Testing and measuringtechniques-Testmeth-

odsforprotectivedevicesforHEMPandotherradiateddisturbances)

IEC 61000-4-24.1997 Electromagnetic compatibility test and measurement techniques - Protection against HEMP and other devices that conduct disturbances

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 4365-2003 · IEC 60050 · IEC 61000 · GB/T 19271.1-2003 · IEC 61312

How to Buy GB/Z 30556.3-2017

  1. 1Add to cart. Click the "Buy GB/Z 30556.3-2017" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 30556.3-2017

$480.00

$410.00for partners