GB/Z 30556.3-2017Electromagnetic compatibility -- Installation and mitigation guidelines -- HEMP protection concepts (English PDF)
Also coversGBZ30556.3-2017
Open the GB/Z 30556.3-2017 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
September 29, 2017
Implementation date
April 1, 2018
Scope
GB/Z 30556.3-2017 (Electromagnetic compatibility -- Installation and mitigation guidelines -- HEMP protection concepts) is available as an English-translated PDF.
GB/Z 30556.3-2017 — This part of GB /Z 30556 defines the concept of protection of electromagnetic pulses generated by high-altitude nuclear explosion (hereinafter referred to as HEMP) and gives Related information. The purpose of this section is to provide some groundwork for the following areas. --- Civil Facilities HEMP adequate protection design; --- The existing protection against the HEMP strength assessment; --- Comparison of HEMP protection and lightning protection requirements, the purpose is to show whether they can low-cost combination; --- Emphasized the difference between HEMP protection and lightning protection requirements, the purpose is to assess when there is no additional lightning protection Protective measures HEMP results.
Document preview — GB/Z 30556.3-2017
National Standard of the People's Republic of China
- ICS
- 33.100.01
- Classification
- L 06
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
Foreword
The Electromagnetic Compatibility Installation and Mitigation Guidelines are divided into the following sections.
--- GB/T 30556.7-2014 Electromagnetic compatibility installation and mitigation guidelines Enclosure electromagnetic disturbance protection class (EM code).
This section GB /Z 30556 Part 3.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with IEC /T R61000-5-3.1999 "Electromagnetic Compatibility Installation and Mitigation Guidelines Part 5-3.
High-altitude nuclear electromagnetic pulse (HEMP) protection concept. "
The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
High pressure test techniques - Part 2. Measuring system (IEC 60060-2.1994, IDT);
--- GB/T 17626.24-2012 electromagnetic compatibility test and measurement techniques HEMP conduction disturbance protection test methods
(IEC 61000-4-24.1997);
--- GB/T 18039.8-2012 Electromagnetic compatibility environment High altitude nuclear electromagnetic pulse (HEMP) Environmental Description Conducted Harassment
(IEC 61000-2-10.1998, IDT);
--- YD/T 2191.4-2012 Telecommunication equipment installation and mitigation measures EMC - Part 4. High altitude electromagnetic pulse
(HEMP) Immunity Technical Requirements for Overhead Electromagnetic Pulse Radiated Interference Protection Devices (IEC /T R61000-5-4.1996,
MOD).
This part of the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246) and focal point.
This part of the drafting unit. Ministry of Industry and Information Technology Institute of Electronics Industry Standardization.
1 Scope
This part of GB /Z 30556 defines the concept of protection of electromagnetic pulses generated by high-altitude nuclear explosion (hereinafter referred to as HEMP) and gives
Related information.
The purpose of this section is to provide some groundwork for the following areas.
--- Civil Facilities HEMP adequate protection design;
--- The existing protection against the HEMP strength assessment;
--- Comparison of HEMP protection and lightning protection requirements, the purpose is to show whether they can low-cost combination;
--- Emphasized the difference between HEMP protection and lightning protection requirements, the purpose is to assess when there is no additional lightning protection
Protective measures HEMP results.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility [IEC 60050 (161) .1990, IDT]
Electromagnetic compatibility (EMC) test and measurement techniques Surge (immunity) immunity test (IEC 61000-4-5).
2005, IDT)
GB/T 19271.1-2003 lightning electromagnetic pulse protection Part 1. General (IEC 61312-1.1995, IDT)
High voltage test techniques - Part 2. Measurement systems (High - voltagetesttechniques - Part 2.
Measuringsystems
Surge arresters - Part 1. Surge arresters for AC systems -
Part 1.Non-linearresistortypegappedsurgearrestersfora.c.systems)
IEC 61000-2-9.1996 Electromagnetic compatibility (EMC) part 2-9. Environment HEMP environment Description Radiation Harassment (Elec-
tromagneticcompatibility (EMC) -Part 2.Environment-Section9.DescriptionofHEMPenviron-
ment-Radiated disturbance
IEC 61000-2-10.1998 Electromagnetic compatibility (EMC) part 2-10. Environment HEMP environment Description Conducted disturbance
(Electromagneticcompatibility (EMC) -Part 2-10.Environment-DescriptionofHEMPenviron-
ment-Conducteddisturbance
IEC 61000-2-11, Electromagnetic compatibility (EMC), part 2-11 Environmental HEMP Environmental Description HEMP Environmental Classification
(Electromagneticcompatibility (EMC) -Part 2-11.Environment-DescriptionofHEMPenviron-
ment-Classification of HEMPenvironments)
IEC 61000-4-23, Electromagnetic compatibility testing and measurement techniques - Test methods for devices protecting HEMP and other radiated disturbances
(Electromagneticcompatibility (EMC) -Part 4-23.Testing and measuringtechniques-Testmeth-
odsforprotectivedevicesforHEMPandotherradiateddisturbances)
IEC 61000-4-24.1997 Electromagnetic compatibility test and measurement techniques - Protection against HEMP and other devices that conduct disturbances
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 4365-2003 · IEC 60050 · IEC 61000 · GB/T 19271.1-2003 · IEC 61312
How to Buy GB/Z 30556.3-2017
- 1Add to cart. Click the "Buy GB/Z 30556.3-2017" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 30556.1-2017 — Electromagnetic compatibility -- Installation and mitigation guidelines -- General considerations
GB/Z 30556.2-2017 — Electromagnetic compatibility -- Installation and mitigation guidelines -- Earthing and cabling
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems