GB/Z 30556.1-2017Electromagnetic compatibility -- Installation and mitigation guidelines -- General considerations (English PDF)
Also coversGBZ30556.1-2017
Open the GB/Z 30556.1-2017 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/Z 30556.1-2017 (Electromagnetic compatibility -- Installation and mitigation guidelines -- General considerations) is available as an English-translated PDF.
GB/Z 30556.1-2017 — In order to ensure the electromagnetic compatibility (EMC) of electrical and electronic equipment or systems used in industrial, commercial and residential environments, "Electromagnetic This section of the Guidance on Capacity Building and Mitigation gives general requirements and guidance on mitigation methods. Suitable for those sensitive electrical or electronic equipment And systems and installations that may have a high emission level that may degrade the overall ambient electromagnetic (EM) environment, users, and a range of manufacturer. Mainly applicable to new facilities, but also to the expansion and improvement of existing facilities where economic conditions permit. Suggestions for some specific issues are given elsewhere in the EMC Guide to Installation and Mitigation. For example. Grounding system Including the design and implementation of grounded electrodes and grounded networks, the design and implementation of lapsing instruments or systems with earth or grounded networks, suitable cables As well as the design and implementation of mitigation measures including shielding housings, high frequency filters, isolation transformers and surge protection devices. The recommendations on EMC aspects of the facilities given in this section are neither safety nor the effective transmission of electricity in the facility Lose side However, these two main aspects are also considered in the EMC recommendations. Increase installed sensitive devices or systems EMC, these two aspects can be implemented simultaneously, and with the application of this section recommended practices and standards such as IEC 60364 [3] series Those related safety requirements are not contradictory. Because each facility is unique, designers and installers are responsible for specific facilities Choose the most relevant recommendations.
Document preview — GB/Z 30556.1-2017
National Standard of the People's Republic of China
- ICS
- 33.100.20
- Classification
- L 06
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
Foreword
The EMC Guidelines for Installation and Mitigation currently include the following sections.
--- GB /Z 30556.2-2017 Electromagnetic compatibility installation and mitigation guidelines for grounding and wiring;
--- GB/T 30556.7-2014 Electromagnetic compatibility installation and mitigation guidelines Enclosure electromagnetic disturbance protection class.
This section is Part 1 of the "Guidelines for Installation and Mitigation of Electromagnetic Compatibility."
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical to the International Standard IEC /T R61000-5-1.1996 "Electromagnetic Compatibility Part 5-1 Installation and Subtraction
Slow guidance is generally required. "
The documents of our country that are consistent with the corresponding international documents that are normative references in this section are as follows.
--- GB/T 4365-2003 Electrotechnical terminology Electromagnetic compatibility [IEC 60050 (161) .1990, IDT];
--- GB/T 2900.71-2008 Electrotechnical terminology electrical installations [IEC 60050 (826) .2004, IDT];
--- GB/T 17624.1-1998 Electromagnetic compatibility Overview Electromagnetic compatibility basic terms and definitions of the application and interpretation
[IEC 61000-1-1.1992, IDT];
--- GB /Z 18039.1-2000 Electromagnetic compatibility Environment Electromagnetic environment classification [IEC 61000-2-5.1996, IDT];
--- GB/T 17626 electromagnetic compatibility test and measurement technology (IEC 61000-4, IDT) (all parts).
This part of the National Electromagnetic Compatibility Standardization Technical Committee (SAC/TC246) and focal point.
This section is drafted unit. Shanghai Institute of Measurement and Testing Technology, Ministry of Industry and Information Technology Institute of Electronics Industry Standardization, China Power
Scientific Research Institute, the recognition is still moving (Shanghai) Testing Technology Co., Ltd., Shanghai Exit Inspection and Quarantine, Suzhou Tai Site Electronic Technology Co., Ltd.
Secretary, Nanjing Nat Communications Electronics Co., Ltd.
1 Scope
In order to ensure the electromagnetic compatibility (EMC) of electrical and electronic equipment or systems used in industrial, commercial and residential environments, "Electromagnetic
This section of the Guidance on Capacity Building and Mitigation gives general requirements and guidance on mitigation methods. Suitable for those sensitive electrical or electronic equipment
And systems and installations that may have a high emission level that may degrade the overall ambient electromagnetic (EM) environment, users, and a range of
manufacturer. Mainly applicable to new facilities, but also to the expansion and improvement of existing facilities where economic conditions permit.
Suggestions for some specific issues are given elsewhere in the EMC Guide to Installation and Mitigation. For example. Grounding system
Including the design and implementation of grounded electrodes and grounded networks, the design and implementation of lapsing instruments or systems with earth or grounded networks, suitable cables
As well as the design and implementation of mitigation measures including shielding housings, high frequency filters, isolation transformers and surge protection devices.
The recommendations on EMC aspects of the facilities given in this section are neither safety nor the effective transmission of electricity in the facility
Lose side However, these two main aspects are also considered in the EMC recommendations. Increase installed sensitive devices or systems
EMC, these two aspects can be implemented simultaneously, and with the application of this section recommended practices and standards such as IEC 60364 [3] series
Those related safety requirements are not contradictory. Because each facility is unique, designers and installers are responsible for specific facilities
Choose the most relevant recommendations.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 60050 (161) .1990 International Electrotechnical Vocabulary chapter 161. Electromagnetic compatibility [International Electrotechnical Vo-
cabulary (IEV) -Chapter161.Electromagneticcompatibility]
IEC 60050 (826) .1982 International Electrotechnical Vocabulary Chapter 826. Electrical installation of buildings [International Electrotechnical-
nicalVocabulary (IEV) -Chapter826.Electricalinstalationsofbuildings]
IEC 61000-1-1.1992 Electromagnetic compatibility (EMC) Part 1. Overview Chapter 1. Basic terms and definitions of the application and interpretation
[Electromagneticcompatibility (EMC) -Part 1.General-Section1.Applicationandinterpretation
offundamentaldefinitionsandterms]
IEC 61000-2-5.1995 Electromagnetic compatibility (EMC) Part 2. Environment Chapter 5. Classification of the electromagnetic environment Electromagnetic compatibility
Standard [Electromagneticcompatibility (EMC) -Part 2.Environment-Section5.Classificationof
electromagneticenvironments-BasicEMCpublication]
IEC 61000-4 Electromagnetic compatibility (EMC) Part 4. Test and measurement techniques [Electromagneticcompatibility
(EMC) -Part 4.Testingandmeasurementtechniques] (all parts)
IEC 61024-1.1990 lightning protection of buildings Part 1. General principles [Protectionofstructuresagainst
lighting-Part 1.Generalprinciples]
3 Terms and definitions
Terms and definitions defined in IEC 60050 (161) and IEC 60050 (826) apply to this document.
A list of abbreviations is provided at the end of this chapter.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60050 · IEC 61000 · IEC 61024
How to Buy GB/Z 30556.1-2017
- 1Add to cart. Click the "Buy GB/Z 30556.1-2017" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/Z 30556.2-2017 — Electromagnetic compatibility -- Installation and mitigation guidelines -- Earthing and cabling
GB/Z 30556.3-2017 — Electromagnetic compatibility -- Installation and mitigation guidelines -- HEMP protection concepts
GB/Z 120.305-2026 — Microgrids - Part 3-5: Testing for microgrid monitoring, control, and energy management systems