Scope

GB/Z 30418-2013 is the English-translated version of 灯具 IK代码的应用.

GB/Z 30418-2013, identical to IEC/TR 62696:2011, explains how the IK code of IEC 62262, which grades the protection of enclosures against external mechanical impacts, is applied to luminaires.

It treats the IK rating of a luminaire as a performance matter, not directly linked to the safety requirements of IEC 60598.

The test requirements cover mounting the complete luminaire on a hardwood board, a pole or a suitable structure, testing it de-energized and without preconditioning, the number and position of impacts, openings smaller than 64 cm² that are not struck, and the use of a spring hammer up to IK06 and a pendulum or vertical hammer from IK07 upwards.

Pass criteria after impact complete the document. It was issued on 31 December 2013.

Found what you need?

Document preview — GB/Z 30418-2013

National Standard of the People's Republic of China

ICS
29.140.40
Classification
K 73

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Test requirements
  • 4 Pass judgment

Foreword

This instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009.

This Guidance Document uses the translation method equivalent to IEC /T R62696.2011 "Lamp IEC /T R62696 IK Code use".

Our document, which corresponds in a consistent manner to the international documents that are normative references in this Guidance Document, is as follows.

--- GB 7000 (all parts) lamps [IEC 60598 (all parts)]

--- GB 7000.1-2007 Lamps - Part 1. General requirements and tests (IEC 60598-1:2003, IDT)

--- GB/T 2423.55-2006 Environmental testing for electric and electronic products Part 2. Test methods Test Eh. Hammer test (IEC 60068-2-75:1997, IDT)

--- GB/T 20138-2006 Protection degree (IK code) of electrical equipment enclosure to external mechanical collision (IEC 62262:2002, IDT)

Introduction

The following IK codes for resistance to mechanical shock, given in IEC 62262, are regulated by the product standards committee.

- shell definition;

- impact test device used;

- the number of test samples;

- test sample installation conditions;

- test sample pretreatment;

- whether the test carried out under power;

- whether the movable part of the mobile test;

- the number of impact and impact location;

Other aspects of luminaires that are specifically considered may also apply, for example.

1 Scope

This guidance document contains the lamp test and classification in IEC 62262. Applying IK ratings to luminaires is considered a performance issue However, it is not directly related to the safety clause in IEC 60598 that covers the safety of luminaires.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

IEC 60068-2-75 Environmental tests - Part 2-75. Tests Eh. Environmental test- Part 2-75.Tests-TestEh.Hammertests)

IEC 60598 (all parts) Luminaires

IEC 60598-1 lamps Part 1. General requirements and tests (Luminaires-Part 1: Generalrequirementsandand tests

IEC 62262 electrical equipment shell on the external mechanical collision protection level (IK code) [Degreesofprotectionprovided byenclosuresforelectricalequipmentagainstexternalmechanicalimpacts (IKcode)]

3 Test requirements

3.1 In general, the test is carried out in accordance with IEC 62262, taking into account the general test conditions specified in 4.13 of IEC 60598-1 and the following The specified IK test and lamp classification conditions.

3.2 Impact should not be applied to the opening area of less than 64cm² lamp housing.

For example, in a shading grid, no impact will be used if a single opening size is less than 64 cm².

3.3 The test should be carried out under the complete assembly and installation of the lamp.

For ceiling or wall-mounted luminaires, they should be mounted on a hardwood board.

Hanging luminaires should be tested under normal use in accordance with the minimum hanging length described on the manufacturer's product manual.

Luminaires mounted on poles or poles, with or without cantilever, should be mounted on rough posts on poles or poles.

Ground-mounted luminaires shall be tested with a suitable rough structure to simulate the normal use of the luminaire.

3.4 In the testing process, the lamp should not be energized, lamp samples without pretreatment requirements.

3.5 The test shall be performed under a single luminaire sample unless the impact test results elsewhere in the luminaire may affect the assessment. 3 times the impact Should be considered at the point where the luminaire is the weakest.

3.6 The impact test shall be made using the impact element of the head with the radius and material specified in IEC 60068-2-75. For the rating does not exceed IK06 should use a spring hammer. For IK07 ratings and above, depending on the design and intended installation of the luminaire, a pendulum or Vertical drop hammer device.

3.7 When possible, lamp installation may affect the test results (for example, the installation of a fixed surface safety assessment), the impact test Should be expected in the lamp installation location. When the impact test is required from underneath a ceiling luminaire which is not feasible To achieve the purpose of the test, the luminaire can be rotated by 90 ° (to a wall-mounted position).

3.8 If the impact test can not be performed due to the structure of the lamp, a special lamp can be used to complete the test. In this kind of In the circumstances, the change of the luminaire should not impair its mechanical strength characteristics.

4 Pass judgment

4.1 Lamp safety To maintain the requirements of 4.13 of IEC 60598-1. Moreover, the fixture on the mounting surface should be firmly fixed. Lamps

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60068-2-75 · IEC 60598 · IEC 60598-1 · IEC 62262

Similar standards

How to Download GB/Z 30418-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 30418-2013

$75.00