Superseded

GB/Z 29496.2-2013Control and communication network CC-Link Safety Specification -- Part 2: Profiles (English PDF)

控制与通信网络CC-Link Safety 规范 第2部分:行规

Preview PDF

This is a limited preview

Buy now to download the full PDF (31 pages)

Need quotation for your management?

Get a formal quotation for GB/Z 29496.2-2013 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China, China National Standardization Administration

Level / Type

National · Recommended

Issue date

July 19, 2013

Implementation date

December 15, 2013

Scope

GB/Z 29496.2-2013 is the English-translated version of 控制与通信网络CC-Link Safety 规范 第2部分:行规.

GB/Z 29496.2-2013 — This part of GB/Z 29496 describes the CC-LinkSafety code of conduct specification. This section provides the safety CSP [CC-Link system rules (safety)] presentation of the document, which describes the CC-Link Different information about safety slaves in Safety.

The CLPA member developer of the safety slave defines the safety slaves profile in the safety CSP file and provides it with the safety slaves file. The user can easily configure the safety slave parameters by downloading the safety CSP file (see Figure 1) to the tool software. Figure 1 Secure CSP file

Found what you need?

Document preview — GB/Z 29496.2-2013

National Standard of the People's Republic of China

ICS
25.040
Classification
N 10

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Secure CSP files and tools
  • 4.1 Goal
  • 4.2 Safety CSP file usage
  • 4.3 Compatibility with standard CSP files
  • 4.4 Operating Precautions
  • 5 Safety CSP file definition
  • 5.1 Safety CSP file name
  • 5.2 Security CSP file structure
  • 5.3 File information section
  • 5.4 Equipment Information Section
  • 5.5 Parameter information section
  • 5.5.1 Structure of parameter information section
  • 5.5.2 Second level segment
  • 5.5.3 Third level segment
  • 5.5.4 Fourth level segment
  • 5.6 SafetyCSP file example
  • 5.6.1 Overview
  • 5.6.2 Security CSP file revision example
  • Figure 1 Secure CSP file
  • Figure 2 Secure CSP file processing flow
  • Figure 3 the structure of a secure CSP file
  • Figure 4 Example file information section
  • Figure 5 Device Information Example
  • Figure 6 structure of the parameter information section
  • Figure 7 Parameter List Overview
  • Figure 8 Parameter information section example
  • Figure 9 second level segment
  • Figure 10 Third level segment
  • Figure 11 fourth level segment
  • Figure 12 RAM storage parameter information section example
  • Figure 13 RAM storage parameters combo box information section Example
  • Figure 14 RAM Memory Parameter Bit Data Message Segment Example
  • Figure 15 Parameter Setting Range Related Information Section Example
  • Figure 16 Example Secure CSP File
  • Figure 17 Pre-revision. Safety CSP File (Module Technical Version A)
  • Figure 18 Revised. Safety CSP Files (Module Technical Version A, B)
  • Table 1 language code list
  • Table 2 document information section of the entry
  • Table 3 Device Information Segment entry
  • Table 4 Equipment Type List
  • Table 5 List of Parameter Information Sections
  • Table 6 second level of information list
  • Table 7 Third-level segment information list
  • Table 8 fourth level segment information list
  • Table 9 RAM Storage Parameter Information Section Entry
  • Table 10 RAM storage parameters Combo box Entry item
  • Table 11 RAM Storing Parameters Bit Data Section Entry
  • Table 12 Log entries for ROM storage parameter information section
  • Table 13 ROM storage parameters Combo box Information entry
  • Table 14 ROM Storage Parameter Bit Data Field of entries
  • Table 15 Parameter setting range Entry of related information section

Foreword

GB/Z 29496 "Control and Communication Network CC-LinkSafety Specification" is divided into the following three sections.

--- Part 1. Overview/Agreement;

--- Part 2. Routine;

--- Part 3. Achieve.

This section GB/Z 29496 Part 2.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This part of the revision adopted the CC-LINK Association standard BAP-C1603-003-C "CC-LinkSafety Code of Conduct." this part of the technical content with the original international standards there is no difference, for the convenience of our users, in the text of the layout of the following Adjustment.

--- This part of the revision uses the original English standard Part 3 BAP-C1603-003-C;

--- Rewrite the foreword of this section;

--- According to the reference standard in the article, an increase of Chapter 2 Normative references;

--- Chapter 2 of the original text as the third chapter of this section, and adjust the subsequent text reg number.

This part is proposed by China Machinery Industry Federation.

This part of the National Industrial Process Measurement and Control Standardization Technical Committee (SAC/TC124) centralized.

This part of the drafting unit. Machinery Industry Instrumentation Comprehensive Technology and Economy Institute, Beijing and Belgium Systems Engineering Co., Ltd., Tsinghua University Dongfeng Design Institute Co., Ltd., Shanghai Automation Instrumentation Co., Ltd., Chongqing Chuan Yi Automation Co., Ltd., CNOOC Research Center, Tianhua Chemical Machinery and Automation Research and Design Institute, China CC-Link user organizations.

1 Scope

This part of GB/Z 29496 describes the CC-LinkSafety code of conduct specification.

This section provides the safety CSP [CC-Link system rules (safety)] presentation of the document, which describes the CC-Link Different information about safety slaves in Safety.

The CLPA member developer of the safety slave defines the safety slaves profile in the safety CSP file and provides it with the safety slaves file.

The user can easily configure the safety slave parameters by downloading the safety CSP file (see Figure 1) to the tool software.

Figure 1 Secure CSP file

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 19760.3 CC-Link control and communication network specification - Part 3 - CC-Link rules

3 Terms and definitions

The following terms and definitions apply to this document.

Safety CSP safetyCSP Abbreviation for CC-Link System Code (Security). Read as CC-Link system code safety version.

Standard CSP standardCSP Abbreviation for CC-Link System Profile (Standard). Read CC-Link system as a standard version of the rules.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 31 pages — is available in the English PDF.

Referenced standards

How to Download GB/Z 29496.2-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
31 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 29496.2-2013

$525.00