Scope

GB/Z 213-2026 is the English-translated version of 金属材料 用于动态疲劳试验的温度验证方法.

GB/Z 213-2026 is the Chinese standard "Metallic Materials - Temperature verification method applied to dynamic fatigue testing". Its scope clause reads: This document establishes validation procedures for determining the accuracy, response speed, and stability of temperature measurements in materials testing equipment.

These procedures... Designed for the intended use of metal fatigue testing, the accuracy of these properties is crucial for testing at high or varying temperatures.

This document is applicable to end-to-end verification of the “true” temperature at the measurement points of a sample, and should not be used to specify the correct measurement method or location.

Note. These methods have also been used for test types other than mechanical fatigue of metals, but this is not within the scope of this document. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/Z 213-2026

National Standard of the People's Republic of China

ICS
77.040.10
Classification
H 22

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Introduction IV
  • 1.Scope
  • 2 Normative References
  • 3.Terms and Definitions
  • 4.Measurement characteristics
  • 5 Representative verification equipment
  • 6.Isothermal Verification Method
  • 7.Evaluation of long-term measurement drift 6.
  • 9 Test Report
  • Appendix A (Informative) Specific Precautions for Specimen Temperature Measurement in Fatigue Testing
  • References

1 Scope

This document establishes validation procedures for determining the accuracy, response speed, and stability of temperature measurements in materials testing equipment. These procedures...

Designed for the intended use of metal fatigue testing, the accuracy of these properties is crucial for testing at high or varying temperatures.

This document is applicable to end-to-end verification of the “true” temperature at the measurement points of a sample, and should not be used to specify the correct measurement method or location.

Note. These methods have also been used for test types other than mechanical fatigue of metals, but this is not within the scope of this document.

2 Normative references

This document has no normative references.

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 testsystem

Equipment used for temperature measurement during (fatigue) testing.

Note 1.The testing system includes clamping or fixing devices, representative specimens, heating system (all parts affecting the measurement), and measurement adjustment devices (such as thermocouples).

(Regulation system), data recording device and software.

Note 2.This validation must be performed on a complete test system, but strictly speaking, it is acceptable if all components affecting the sample environment are in a representative configuration.

If the state is such that a loading framework is not necessarily required, then a loading framework is not necessarily required.

Note 3.The operating environment of the test system can be considered part of the verification, because temperature variations in electronic equipment can affect measurement results, especially in hot environments.

When the cold junction of the thermocouple or the detector array of the thermo-optical device is not in a constant temperature state.

Note 4.A good laboratory environment is usually maintained through some form of climate control, but this is not achievable in all cases, and climate control cannot guarantee complete protection.

To completely avoid localized problems in specific instruments.

3.2

The samples used during the verification process.

Samples of similar shape, thermal conductivity, and emissivity are required. Ideally, the representative sample should be the actual sample to be tested, without significantly affecting the system.

Under the premise of heat transfer characteristics, a certain degree of deviation is allowed.

3.3 Reference system

An independent measurement system for verifying the test system (3.1).

Note. The resolution of the reference system should be at least 3 times higher (preferably more than 5 times) than that of the verification test system, and it should be traceable.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Similar standards

How to Download GB/Z 213-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/Z 213-2026

$300.00