Valid

GB/T 9978.5-2008Fire-resistance tests -- Elements of building construction -- Part 5: Specific requirements for loadbearing horizontal separating elements (English PDF)

建筑构件耐火试验方法 第5部分:承重水平分隔构件的特殊要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9978.5-2008 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

June 26, 2006

Implementation date

March 1, 2009

Scope

GB/T 9978.5-2008 is the English-translated version of 建筑构件耐火试验方法 第5部分:承重水平分隔构件的特殊要求.

GB/T 9978.5-2008 — This section GB/T 9978 specifies the test method for determining the fire resistance of the load-bearing horizontal partition members whose surface is exposed to fire.

This section also applies to the horizontal load-bearing separation of such girders if the roof or floor elements are not supported by the girders and can not be tested member.

However, test data can not be transferred directly between the two specimen components.

When the structure of untested building components in line with the conditions of direct application scope given in this section has been carried out in accordance with the provisions of this section Fire resistance test of the components of the fire resistance results can be applied to similar components of the building has not been tested.

Found what you need?

Document preview — GB/T 9978.5-2008

National Standard of the People's Republic of China

ICS
13.220.50
Classification
C 82

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols and abbreviations
  • 5 Test device
  • 6 Test conditions
  • 7 Specimen preparation
  • 8 Instrument to use
  • 9 Test methods
  • 10 Decision Criterion
  • 11 The validity of the test
  • 12 Test results that
  • 13 Test Report
  • Appendix A (informative) Guide to the direct application of test results
  • Appendix B (informative) This section reg number and ISO 834-5.:2000 reg Article number control
  • Appendix C (informative) This part of ISO 834-5.:2000 technical differences and their causes
  • Reference

Foreword

GB/T 9978 "fire test method for building components" is expected to be divided into the following sections.

--- Part 1. General requirements;

--- Part 2. Fire test furnace calibration;

--- Part 3. Test methods and test data application notes;

--- Part 4. Bearing vertical separation member of the special requirements;

--- Part 5. load-bearing horizontal partition special requirements;

--- Part 6. Beam special requirements;

--- Part 7. special requirements of the column;

--- Part 8. Non-load-bearing vertical partition special requirements;

--- Part 9. Non-load-bearing ceiling components of the special requirements;

This section GB/T 9978 Part 5.

This part of the amendment uses ISO 834-5.:2000 "fire test building components - Part 5. load-bearing horizontal partition member special Seeking "(English version).

This section is based on ISO 834-5.:2000 redrafted. Appendix A of the original ISO 834-5.:2000 Appendix, Appendix B lists the headquarters Sub-chapter number and ISO 834-5.:2000 Chapter Article number control list.

Taking into account China's national conditions, the adoption of ISO 834-5.:2000, made some changes in this section. The relevant technical differences have been incorporated into the text and marked with a vertical single line in the margins of the terms of the articles they cover. These technical differences and their precursors are given in Appendix C.

Because of the list, for reference.

For ease of use, corresponding to ISO 834-5.:2000, this section also made the following editorial changes.

--- "This part of ISO 834" was revised to "This part of GB/T 9978";

--- Use the decimal point "." Instead of as a decimal point comma ",";

--- Remove the foreword and foreword of the international standard.

This part of Appendix A, Appendix B and Appendix C are informative appendix.

This part is proposed by the Ministry of Public Security of the People's Republic of China.

This part of the National Fire Standards Technical Committee fire building components Technical Committee (SAC/TC113/SC8) centralized.

This section is drafted. Tianjin Fire Institute Ministry of Public Security.

1 Scope

This section GB/T 9978 specifies the test method for determining the fire resistance of the load-bearing horizontal partition members whose surface is exposed to fire.

This section also applies to the horizontal load-bearing separation of such girders if the roof or floor elements are not supported by the girders and can not be tested member. However, test data can not be transferred directly between the two specimen components.

When the structure of untested building components in line with the conditions of direct application scope given in this section has been carried out in accordance with the provisions of this section Fire resistance test of the components of the fire resistance results can be applied to similar components of the building has not been tested.

2 Normative references

The following documents contain provisions which, through reference in this part of GB/T 9978, become the provisions of this section. For dated references, its subsequent Amendments (not including errata content) or revisions do not apply to this section, however, to encourage the agreement reached under this section the parties studied whether the latest versions of these documents are available. For undated references, the latest version applies to this section.

GB/T 5907 fire basic terms first part 1)

1) The standard will be based on the revised revisions GB/T 5907-1986, GB/T 14107-1993 and GB/T 16283-1996, with "Fire Vocabulary" as the total title, divided into five parts. Among them, the second part is GB/T 5907.2 "Fire Vocabulary Part 2. Fire Safety Vocabulary," will be amended to adopt ISO 13943.:2000.

GB/T 9978.1 fire test methods for building components - Part 1. General requirements (GB/T 9978.1-2008, ISO 834-1.

1999, MOD)

GB/T 9978.6 fire test methods for building components - Part 6. Particular requirements for beams (GB/T 9978.6-2008, ISO 834-6.:2000, MOD)

3 Terms and definitions

GB/T 5907 and GB/T 9978.1 established and the following terms and definitions apply to this section.

Horizontal guide bearing structure in building structure.

Note. They can form a composite with the structure they support, or they can be separated from the structure they support.

The test piece is exposed to the effective length of the fire in the test furnace.

The test specimen is exposed to the effective width of the fire in the test furnace.

Load-bearing horizontal separation between two floors in a building structure.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 9978.5-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9978.5-2008

$125.00