GB/T 8704.9-2009Ferrovanadium - Determination of manganese content - The potassium periodate oxidation photometric method and flame atomic absorption spectrometric method (English PDF)
钒铁 锰含量的测定 高碘酸钾光度法和火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 8704.9-2009 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 15, 2009
Implementation date
April 1, 2010
Scope
GB/T 8704.9-2009 is the English-translated version of 钒铁 锰含量的测定 高碘酸钾光度法和火焰原子吸收光谱法.
GB/T 8704.9-2009 is the part of GB/T 8704 that determines manganese in ferrovanadium, by potassium periodate oxidation photometry and by flame atomic absorption spectrometry.
For the photometric method it gives the principle and the reagents: dissolution in sulfuric and phosphoric acid, oxidation of the manganese to permanganate with potassium periodate, absorbance read at 525 nm against a calibration curve, and a manganese standard solution of 100 µg per mL prepared from metal of mass fraction greater than 99.9%.
The range is a mass fraction of 0.05% to 0.60% for the potassium periodate method and 0.10% to 1.00% for flame atomic absorption. It quotes GB/T 4010, replaces GB/T 8704.9-1994, was issued on 15 July 2009 and has applied since 1 April 2010.
Found what you need?
Document preview — GB/T 8704.9-2009
National Standard of the People's Republic of China
- ICS
- 77.100
- Classification
- H 11
- Replacing
- GB/T 8704.9-1994
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Method One. potassium periodate photometric method
Foreword
This Part replaces GB/T 8704.9-1994 "Methods for chemical analysis of ferrovanadium potassium periodate photometric and flame atomic absorption spectrometric measurement method Given the amount of manganese. " This portion of the GB/T 8704.9-1994 comparison, the main changes are.
--- Remove the flame atomic absorption spectrometry Appendix A.
1 Scope
This section GB/T 8704 regulations using potassium periodate photometric and flame atomic absorption spectrometry determination of vanadium in the iron and manganese content.
This section applies to the determination of vanadium iron and manganese content. Potassium periodate spectrophotometric measurement range (mass fraction) of 0.05% to 0.60%; the flame Atomic Absorption Spectrometry range (mass fraction) 0.10% to 1.00%.
2 Normative references
The following documents contain provisions cited by GB/T 8704 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 4010 alloy chemical analysis and preparation of samples
3 Method One. potassium periodate photometric method
3.1 Principle
Samples with sulfuric acid - phosphoric acid dissolved in potassium periodate oxidation of manganese to permanganate, 525nm wavelength measured absorbance on a spectrophotometer degree. Quality on the calibration curve Richard manganese content in the sample is calculated in manganese.
3.2 Reagents and materials
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or its equivalent purity water.
3.2.1 High potassium iodate, solid.
3.2.2 Phosphoric acid, rho1.70g/mL.
3.2.3 Nitrate, rho1.42g/mL.
3.2.4 Hydrofluoric acid, rho1.15g/mL.
3.2.5 Sulfate, 1 + 4.
3.2.6 EDTA (edetate disodium dihydrate) was added, 100g/L. Weigh 100g of disodium ethylenediamine tetraacetate dihydrate 200mL water (C10H14N2O8Na2 · 2H2O) was dissolved in 5mL containing ammonium hydroxide (rho0.90g/mL), and diluted with water 1000mL.
3.2.7 does not contain water reducing substance. in 1000mL of water were added 20mL sulfuric acid (1 + 1), adding a small amount under the micro-boiling state (About 2g) potassium periodate (3.2.1), and held for about 10min. Cooled, stored in a glass bottle and set aside.
3.2.8 Manganese standard solution. Weigh 0.1000g Jinzhumeng [mass fraction is greater than 99.9%, pre-washed to remove table in sulfuric acid (5 + 95) Oxide surfaces, removed, washed with water immediately clean and washed 2 or 3 times with ethanol, and air-dried to use] 300mL beaker was placed Was added 20mL of hydrochloric acid (1 + 1), 20mL sulfuric acid (1 + 1), dissolved by heating, and evaporated to take the drive out white smoke of sulfuric acid, hydrochloric acid, cooled to room temperature. Moved into 1000mL volumetric flask, dilute with water to volume, and mix. This solution 1mL manganese 100µg.
3.3 Instrument
Analysis using common laboratory instruments.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
Similar standards
Editions of GB/T 8704.9
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 8704.9-2009 | Ferrovanadium - Determination of manganese content - The potassium periodate oxidation photometric method and flame atomic absorption spectrometric method | current edition | Current |
| GB/T 8704.9-1994 | Ferrovanadium - Determination of manganese content - The potassium periodate oxidation photometric method and flame atomic absorption spectrometric method | previous edition | Superseded |
This page sells the current edition, GB/T 8704.9-2009. Earlier editions are listed for reference only.
How to Download GB/T 8704.9-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4010-1994 — Ferroalloys-sampling and preparation of samples for chemical analysis
GB/T 4010-2015 — Ferroalloys sampling and preparation of samples for chemical analysis
GB/T 8704.10-2020 — Ferrovanadium—Determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel and titanium contents— Inductively coupled plasma atomic emission spectrometric method