Scope
GB/T 8704.10-2020 is the English-translated version of 钒铁 硅、锰、磷、铝、铜、铬、镍、钛含量的测定 电感耦合等离子体原子发射光谱法.
GB/T 8704.10-2020 is the Chinese standard "Ferrovanadium—Determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel and titanium contents— Inductively coupled plasma atomic emission spectrometric method".
Its scope clause reads: This part of GB/T 8704 specifies the determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel, titanium by inductively coupled plasma emission spectrometry content.
This section applies to the determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel, and titanium in ferrovanadium. For the determination range of each element, see Table 1.
Table 1 Determination range of each element Determination of element content range (mass fraction)/% Determination of element content range (mass fraction)/% Silicon 0.10~5.00 Copper 0.010~0.20 Manganese 0.010~1.20 Chromium 0.010~1.20 Phosphorus 0.010~0.20 Nickel 0.010~0.40 Aluminum 0.10~5.00 Titanium 0.010~1.00. Its clauses include principle.
Found what you need?
Document preview — GB/T 8704.10-2020
National Standard of the People's Republic of China
- ICS
- 77.100
- Classification
- H 11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
1 Scope
This part of GB/T 8704 specifies the determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel, titanium by inductively coupled plasma emission spectrometry content.
This section applies to the determination of silicon, manganese, phosphorus, aluminum, copper, chromium, nickel, and titanium in ferrovanadium. For the determination range of each element, see Table 1.
Table 1 Determination range of each element
Determination of element content range (mass fraction)/% Determination of element content range (mass fraction)/%
Silicon 0.10~5.00 Copper 0.010~0.20
Manganese 0.010~1.20 Chromium 0.010~1.20
Phosphorus 0.010~0.20 Nickel 0.010~0.40
Aluminum 0.10~5.00 Titanium 0.010~1.00
2 Normative references
The following documents are essential for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
Selection and preparation of GB/T 4010 samples for chemical analysis of ferroalloys
GB/T 6379.1 Accuracy of measurement methods and results (correctness and precision) Part 1.General rules and definitions
GB/T 6379.2 Accuracy of measurement methods and results (correctness and precision) Part 2.Determination of repetition of standard measurement methods
Basic methods of sex and reproducibility
GB/T 6682 Analysis of laboratory water specifications and test methods
GB/T 8170 Numerical Rounding Rules and Representation and Judgment of Limit Values
GB/T 12806 Laboratory glass instrument single mark volumetric flask
GB/T 12807 Laboratory glass instrument graduation pipette
GB/T 12808 Laboratory glass instrument single mark pipette
3 Principle
The sample was dissolved with nitric acid-hydrochloric acid at low temperature, and the residue was melted with sodium carbonate-boric acid mixed flux and leached with hydrochloric acid. Test solution via inductively coupled plasma
The body emission spectrometer atomization sampling system introduces the test solution into the plasma, and the elements to be measured in the sample solution are evaporated and decomposed under the action of high temperature.
Separated, atomized, and excited to emit their respective characteristic spectra, after the dispersion of the spectroscopic system, the signal intensity of its characteristic spectral line is detected to correspond to the calibration […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4010Ferroalloys sampling and preparation of samples for chemical analysis
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
- GB/T 12806Laboratory glassware -- One-mark volumetric flasks
Similar standards
How to Download GB/T 8704.10-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12806-2011 — Laboratory glassware -- One-mark volumetric flasks
GB/T 12807-2021 — Laboratory glassware - Graduated pipettes
GB/T 12808-2015 — Laboratory glassware - One mark pipettes
Secure payment via Stripe
Payments accepted
GB/T 8704.10-2020
$300.00