Scope
GB/T 8151.5-2012 is the English-translated version of 锌精矿化学分析方法 第5部分:铅量的测定 火焰原子吸收光谱法.
GB/T 8151.5-2012 is the Chinese standard "Methods for chemical analysis of zinc concentrates - Part 5: Determination of lead content - The flame atomic absorption spectrometric method".
Its scope clause reads: This section GB/T 8151 provisions of the determination of zinc concentrate lead content. This section applies to the determination of zinc concentrate - Determination of lead content range.
0.50% - 6.00%. Its clauses include method summary; reagents; instrument; sample.
Found what you need?
Document preview — GB/T 8151.5-2012
National Standard of the People's Republic of China
- ICS
- 77.120.60
- Classification
- H 13
- Replacing
- GB/T 8151.5-2000
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
- 5 Sample
1 Scope
This section GB/T 8151 provisions of the determination of zinc concentrate lead content.
This section applies to the determination of zinc concentrate - Determination of lead content range. 0.50% - 6.00%.
2 Method summary
Samples with hydrochloric acid, nitric acid dissolved in dilute nitric acid medium, atomic absorption spectrometer at a wavelength of 283.3nm, air - acetylene flame,
Measuring the absorbance of lead.
3 Reagents
Unless otherwise indicated in the analysis using only recognized as analytical reagent and distilled or deionized water or equivalent purity.
3.1
hydrochloride (rho1.19g/mL).
Nitrate 3.2 (rho1.42g/mL).
3.3
nitric acid (11).
3.4 Lead standard solution
Weigh 0.4000g metallic lead (wPb>=99.99%) in 250mL beaker, add 20mL of nitric acid (3.3) cover
Table dish, heated until completely dissolved, to remove nitrogen oxides boil, cooled to room temperature. Transferred 1000mL volumetric flask and dilute to the mark with water, mix
Uniform. This solution 1mL containing 400µg lead.
4 Instrument
Atomic absorption spectrometer, with a lead hollow cathode lamp.
Under instrument conditions, who can achieve the following indicators atomic absorption spectrometer can be used.
--- Characteristic concentration. in the sample solution matrix consistent solution, characterized in lead concentration should not exceed 0.50µg/mL;
--- Precision. the highest concentration of the standard solution with 10 times the absorbance measured, and the standard deviation should not exceed the average absorbance
1.50%; absorbance measured 10 times the minimum concentration of the standard solution (not a "zero" standard solution), and the standard deviation should not exceed
0.50% the highest concentration of the standard average absorbance;
--- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment
Ratio of not less than 0.90.
5 Sample
5.1
Samples should sift through the 0.100mm hole.
5.2
Samples previously 105 °C ± 5 °C baking 1h, cooled to room temperature and placed in the dryer.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of GB/T 8151.5
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 8151.5-2012 | Methods for chemical analysis of zinc concentrates - Part 5: Determination of lead content - The flame atomic absorption spectrometric method | current edition | Current |
| GB/T 8151.5-2000 | Methods for chemical analysis of zinc concentrates - Part 5: Determination of lead content - The flame atomic absorption spectrometric method | previous edition | Superseded |
This page sells the current edition, GB/T 8151.5-2012. Earlier editions are listed for reference only.
How to Download GB/T 8151.5-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 8151.6-2012 — Methods for chemical analysis of zinc concentrates - Part 6: Determination of copper content - The flame atomic absorption spectrometric method
GB/T 8151.4-2000 — Methods for chemical analysis of zinc concentrates -Determination of silicon dioxide content
GB/T 8151.6-2000 — Methods for chemical analysis of zinc concentrates -Determination of copper content
Secure payment via Stripe
Payments accepted
GB/T 8151.5-2012
$85.00