Valid

GB/T 7196-2012Methods of test for the determination of ionic impurities in electrical insulating materials by extraction with liquids (English PDF)

用液体萃取测定电气绝缘材料离子杂质的试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (1977 pages)

Need quotation for your management?

Get a formal quotation for GB/T 7196-2012 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

January 1, 1970

Implementation date

January 1, 1970

Scope

GB/T 7196-2012 is the English-translated version of 用液体萃取测定电气绝缘材料离子杂质的试验方法.

GB/T 7196-2012 — This standard specifies the test method for measuring liquid extraction of ionic impurities in electrical insulating materials.

This standard applies to the determination of the electrical insulating material ionized soluble organic or inorganic substances, based on the volume of the extraction solution conductivity Increases to justify their existence.

The test has a special significance for the refrigerant or impregnant immersed in an electrically insulating material.

Found what you need?

Document preview — GB/T 7196-2012

National Standard of the People's Republic of China

ICS
29.035.99
Classification
K 15
Replacing
GB/T 7196-1987

Issued by: Standardization Administration of China

Contents

  • Preface
  • 1 Scope
  • 2 Terms and definitions
  • 3 Instrument
  • 4 Program
  • 4.1 Water extract

Foreword

This standard rule according to GB/T 1.1-2009 given draft.

This Part replaces GB/T 7196-1987 "Test Method for Determination of electrical insulating materials extraction liquid ionic impurities", and GB/T 7196-1987 compared to the main technical changes are as follows.

--- Will be part of the "note" to modify the contents of text articles.

This standard uses the translation method is equivalent to using IEC 60589. 1977 "was measured by liquid extraction of ionic impurities in electrical insulating materials test side law".

The standard proposed by China Electrical Equipment Industrial Association.

This standard by the national system of assessment and an insulating material Standardization Technical Committee (SAC/TC301) centralized.

This standard was drafted. Guilin Electric Apparatus Research Institute, Shunde quality and technical supervision of standards and codes, Beijing Machinery Industry Electrical Technology and Economy Institute.

1 Scope

This standard specifies the test method for measuring liquid extraction of ionic impurities in electrical insulating materials.

This standard applies to the determination of the electrical insulating material ionized soluble organic or inorganic substances, based on the volume of the extraction solution conductivity Increases to justify their existence. The test has a special significance for the refrigerant or impregnant immersed in an electrically insulating material.

2 Terms and definitions

The following terms and definitions apply to this document.

2.1 Liquid extract volume conductivity volumeconductivityoftheliquidextract

Liquid extract volume conductivity gammaex equal volume of extraction solution conductivity and Comparative test solution (blank test solution) the volume conductivity Difference in SI units in unit volume conductivity is Siemens per meter (S/m). In fact common units of volume conductivity Simon Sub per centimeter (S/cm).

3 Instrument

250mL conical flask of hard glass equipped with a reflux condenser (see Figure 1).

Conductivity cell. a known constant k (1/m or 1/cm).

Accuracy of 5% resistor bridge or other measurable resistance means.

For the water extract, the measuring device should be at a frequency of 50Hz ~ 3000Hz measured resistance to 1Mohm.

Note. I do not know if the cell constant k, can be determined by known conductivity standard solution of potassium chloride in Appendix B.

For organic extracts, the measuring device should be used no more than 100V DC voltage measuring resistor until 1Tohm.

4 Program

4.1 Water extract

4.1.1 Test water

Volume conductivity of the test water shall be less than or equal to 2.0 × 10-4S/m. Wherein the pH should be between 6.8 to 7.2.

Test water can be prepared by ion exchange agent or in compliance with the above pH of distilled water twice.

Note. It should be noted the impact of carbon dioxide, water, freshly prepared, if short-term exposure to air, it will change to a pH between 5.7 to 6.9 If.

Water pH change caused by carbon dioxide, but not less than 6.4, it may be passed through to the water a short time to recover pure nitrogen pH = 7. As the water stored in the Polyethylene bottle carbon dioxide removal, the pH can be kept at the desired range.

4.1.2 Preparation of aqueous extract solutions

The absence of special provisions, water extraction solution is prepared according to the following procedure.

GB/T 7196-2012/IEC 60589. 1977

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 1977 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 7196-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
1977 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7196-2012

$145.00