Valid

GB/T 6910-2026Analysis methods for boiler water and cooling water - Determination of calcium - Complexometric titration (English PDF)

锅炉用水和冷却水分析方法 钙的测定 络合滴定法

Preview PDF

This is a limited preview

Buy now to download the full PDF (24 pages)

Need quotation for your management?

Get a formal quotation for GB/T 6910-2026 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

April 30, 2026

Implementation date

November 1, 2026

Scope

GB/T 6910-2026 is the English-translated version of 锅炉用水和冷却水分析方法 钙的测定 络合滴定法.

GB/T 6910-2026 is the Chinese standard "Analysis methods for boiler water and cooling water - Determination of calcium - Complexometric titration". Its scope clause reads: This document describes a method for determining the calcium content in boiler water and cooling water using complexometric titration.

This document applies to the determination of calcium content in boiler water and cooling water.

The determination range for manual titration is 10 mg/L to.200 mg/L. The determination range for both spectrophotometric titration and potentiometric titration is 2 mg/L to.200 mg/L; water samples with concentrations exceeding.200 mg/L should be diluted before determination.

The determination of calcium content in surface water, groundwater, reclaimed water, and wastewater shall be carried out in accordance with the prescribed procedures.

Its clauses include terms and definitions; manual titration method; photometric titration; potentiometric titration; result calculation and representation; precision; test report.

Found what you need?

Document preview — GB/T 6910-2026

National Standard of the People's Republic of China

ICS
13.060.45
Classification
J 98
Replacing
GB/T 6910-2006

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1.Scope
  • 3.Terms and Definitions
  • 4.Manual titration method
  • 4.1 Principle
  • 4.2 Reagents and Materials
  • 4.2.3 Quantitative filter paper. medium speed.

1 Scope

This document describes a method for determining the calcium content in boiler water and cooling water using complexometric titration.

This document applies to the determination of calcium content in boiler water and cooling water. The determination range for manual titration is 10 mg/L to.200 mg/L.

The determination range for both spectrophotometric titration and potentiometric titration is 2 mg/L to.200 mg/L; water samples with concentrations exceeding.200 mg/L should be diluted before determination.

The determination of calcium content in surface water, groundwater, reclaimed water, and wastewater shall be carried out in accordance with the prescribed procedures.

3 Terms and Definitions

This document does not contain any terms or definitions that need to be defined.

4 Manual titration method

4.1 Principle

Adjust the pH of the water sample to not less than 12, using calcein-phenolphthalein as an indicator, and EDTA disodium salt standard solution.

The endpoint is reached by titrating with the liquid until the yellow-green fluorescence disappears and the solution turns red; or by using calcium carboxylic acid as an indicator, titrating with EDTA standard solution until red.

The color change to bright blue is the endpoint. The calcium ion content is calculated based on the volume of EDTA standard solution consumed. Under these test conditions, the magnesium ion content...

The molecules form magnesium hydroxide precipitate, which does not interfere with the determination.

4.2 Reagents and Materials

Unless otherwise specified, this document shall use reagents of analytical grade or higher.

4.2.1 Water

Grade II water as specified in GB/T 6682.

4.2.2 Microporous filter membrane

aqueous system, pore size 0.45µm.

4.2.3 Quantitative filter paper

medium speed.

4.2.4 Potassium hydroxide solution (200g/L)

Weigh 20g of potassium hydroxide, dissolve it in water and dilute it to 100mL.

4.2.5 Hydrochloric acid solution

Add 100 mL of hydrochloric acid to 100 mL of water and mix well.

4.2.6 Triethanolamine solution

Add 50 mL of triethanolamine to 100 mL of water and mix well.

4.2.7 L-cysteine hydrochloride solution (10g/L). Weigh 10g of L-cysteine hydrochloride, dissolve it in water and dilute it to 1000mL.

4.2.8

EDTA standard solution [c(EDTA)=0.01mol/L]. Prepared and standardized according to GB/T 601.

4.2.9 Calcium carboxylic acid indicator

Weigh 10g of sodium chloride dried at 105°C±2°C for 2h, add 0.1g of calcium carboxylic acid, mix well and grind finely before storage.

In a desiccator.

Note. Calcium carboxylic acid indicator is also known as calcium indicator or calcium red indicator.

4.2.10 Calcein-Phenolphthalein Indicator

Weigh 0.2g calcein and 0.07g phenolphthalein into a mortar, add 20g potassium chloride, and mix well.

After grinding, store in a ground glass bottle.

4.3 Test Procedure

4.3.1

Collect water samples according to GB/T 6903.If the water sample contains visible suspended solids, filter it with quantitative filter paper or microporous membrane.

4.3.2

Take 50.0 mL of water sample into a 250 mL Erlenmeyer flask, add 50 mL of water and 3 drops of hydrochloric acid solution, mix well, and heat to a gentle boil.

Continue for 0.5 min, then cool to room temperature to eliminate interference from bicarbonate and polyacrylic acid.

4.3.3

Add 5 mL of potassium hydroxide solution to the water sample.

4.3.4

Add approximately 0.04 g of calcein-phenolphthalein indicator or calcium carboxylic acid indicator to the water sample.

4.3.5

While continuously shaking, immediately titrate with EDTA standard solution. The titration speed should be slightly faster at the beginning and slightly slower near the endpoint.

When using calcein-phenolphthalein indicator, titrate against a black background until the yellow-green fluorescence disappears and the solution turns red; the endpoint is reached when using calcium carboxylic acid.

When using an indicator, titrate until the solution changes from purple-red to bright blue as the endpoint. The entire titration process should be completed within 5 minutes, and the amount consumed should be recorded.

The volume of EDTA standard solution is V1, accurate to 0.01 mL. A blank test is also performed simultaneously, recording the volume of EDTA standard solution consumed.

V0, accurate to 0.01 mL.

4.3.6

If iron, aluminum, manganese, copper, or zinc ions are present in the water sample, 2-3 mL of triethanolamine solution can be added before step 4.3.3.

Combined masking with 2 mL to 3 mL L-cysteine hydrochloride solution to eliminate interference.

Note. If the water sample is not red after adding the indicator, or if the indicator does not turn bright blue during the titration process, it is suspected that there may be interference.

5 Photometric titration

5.1 Method Overview

The pH of the water sample was adjusted to be no less than 12, using calcium carboxylic acid as an indicator, and analyzed using an automatic potentiometric titrator and photometric electrode, with EDTA standard.

The solution was titrated to the point of abrupt change in the absorbance of the water sample, and the calcium ion content was calculated based on the volume of EDTA standard solution consumed.

Under these test conditions, magnesium ions form magnesium hydroxide precipitate, which does not interfere with the determination.

5.2 Reagents and Materials

Same as 4.2.1 to 4.2.9.

5.3 Instruments and Equipment

5.3.1 Automatic Potentiometric Titrator

It has the function of photometric titration, with a maximum permissible error of ±1.5% for the instrument reading and a repeatability of no more than 0.2%.

5.3.2 Photometric Electrode

The wavelength value can be set in the range of 600nm to 660nm, with a wavelength error of no more than ±10nm and a full width at half maximum of 30nm.

5.4 Test Procedure

5.4.1

After the water sample is processed according to 4.3.1 and 4.3.2, it is transferred entirely to a titration cup, and then the procedure is performed according to 4.3.3.

5.4.2

Add approximately 0.04 g of calcium carboxylic acid indicator to the water sample and mix thoroughly.

5.4.3

Adjust the wavelength of the photometric electrode to the optimal value within the range of 600nm~660nm, place the titration cup containing the water sample on the titration stage, and turn on the titration switch.

Start the instrument and stirrer, titrate with EDTA standard solution, and stop titrating when a complete abrupt change curve appears. Record the stoichiometric point.

The volume of EDTA standard solution consumed is V1, accurate to 0.01 mL. A blank test is also performed simultaneously, and the volume of EDTA standard solution consumed is recorded.

The volume is V0, accurate to 0.01 mL.

6 Potentiometric titration

6.1 Method Overview

Adjust the pH of the water sample to be no less than 12, and titrate calcium ions with EDTA standard solution. The potential of the calcium ion selective electrode changes with the concentration of calcium ions.

The degree of change is continuous and decreases, and a sudden jump occurs in the electrode potential near the stoichiometric point. This is based on the cumulative consumption at the time the stoichiometric point is reached.

The calcium ion content was calculated from the volume of the EDTA standard solution. Under these test conditions, magnesium ions formed magnesium hydroxide precipitate, which did not interfere with the calcium ion content.

Measurement.

6.2 Reagents or Materials

Same as 4.2.1 to 4.2.8.

6.3 Instruments and Equipment

6.3.1

Automatic potentiometric titrator, with a maximum permissible error of ±1.5% for instrument readings and a repeatability of no more than 0.2%.

6.3.2

Calcium ion electrode and reference electrode.

6.4 Test Procedure

6.4.1

After processing according to 4.3.1 and 4.3.2, transfer the entire water sample to the titration cup, and then proceed according to 4.3.3.

6.4.2

Place the titration cup containing the water sample on the titration stage, insert the calcium ion electrode into the water sample, turn on the instrument and stir, and use EDTA standard.

Solution titration. Stop titrating when a complete abrupt change curve appears, and record the volume of EDTA standard solution consumed at the stoichiometric point.

Record the volume of EDTA standard solution consumed as V1, accurate to 0.01 mL. Simultaneously perform a blank test and record the volume of EDTA standard solution consumed as V0, accurate to 0.01 mL.

7 Result Calculation and Representation

The calcium ion content in the water sample is calculated according to formulas (1) to (4).

8 Precision

In the same laboratory, by the same operator using the same equipment, following the same testing methods, and within a short period of time, the same test object is subjected to...

The absolute difference between two independent test results obtained from mutually independent tests shall not exceed the repeatability limit (r); otherwise, the test results shall not be considered valid.

If the value exceeds 5%, the repeatability limit (r) is calculated according to formulas (5) to (7).

In different laboratories, by different operators using different equipment, following the same testing methods, and independently testing the same object...

The absolute difference between two independent test results obtained from the test shall not exceed the reproducibility limit (R), and the number of cases exceeding the reproducibility limit (R) shall not exceed [a certain threshold].

5%, the reproducibility limit (R) is calculated according to formulas (8) to (10).

9 Test Report

The test report should include at least the following information.

---Please indicate the document number;

---Name of the water sample, sampling date, etc.;

---Testing methods used;

---Experimental Results;

---Abnormal phenomena observed during the experiment;

---Trial date.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.

Editions of GB/T 6910

EditionTitleRevisionStatus
GB/T 6910-2026Analysis methods for boiler water and cooling water - Determination of calcium - Complexometric titrationcurrent editionCurrent
GB/T 6910-2006Analysis methods for boiler water and cooling water - Determination of calcium - Complexometric titrationprevious editionIn force until 1 November 2026

This page sells the current edition, GB/T 6910-2026. Earlier editions are listed for reference only.

How to Download GB/T 6910-2026

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
24 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 6910-2026

$255.00