GB/T 6730.63-2024Iron ores - Determination of aluminum, calcium, magnesium, manganese, phosphorus, silicon and titanium content - Inductively coupled plasma atomic emission spectrometric method (English PDF)
Also coversGBT6730.63-2024
Open the GB/T 6730.63-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 28, 2024
Implementation date
December 1, 2024
Scope
GB/T 6730.63-2024 (Iron ores - Determination of aluminum, calcium, magnesium, manganese, phosphorus, silicon and titanium content - Inductively coupled plasma atomic emission spectrometric method) is available as an English-translated PDF.
GB/T 6730.63-2024 — This document specifies the determination of aluminum, calcium, magnesium, manganese, phosphorus, silicon, titanium content by inductively coupled plasma emission spectrometry.
Document preview — GB/T 6730.63-2024
National Standard of the People's Republic of China
Issued by: SAMR; SAC
Contents
- Foreword3
- Introduction6
- 1 Scope7
- 2 Normative references7
- 3 Terms and definitions8
- 4 Principle8
- 5 Reagents and materials8
- 6 Instruments and equipment11
- 7 Sampling and specimen preparation12
- 8 Analytical procedures12
- 9 Calculation of results15
- 10 Test report21
- Appendix A (Informative) Components of GB/T 673022
- Appendix B (Informative) Comparison of structure numbers of this document with ISO 11535.200627
- Appendix C (Informative) Recommended solution concentrations for calibration curves28
- Appendix D (Normative) Performance test of plasma spectrometer29
- Appendix E (Informative) Derivation of repeatability and allowable deviation equations32
- Appendix F (Normative) Acceptance procedure for specimen analysis result33
1 Scope
This document specifies the determination of aluminum, calcium, magnesium, manganese, phosphorus, silicon, titanium content by inductively coupled plasma emission spectrometry.
2 Normative references
The contents of the following documents constitute the essential terms of this document through normative references in the text. Among them, for dated references, only the version corresponding to that date applies to this document; for undated references, the
5.5 Hydrochloric acid, 1 + 1.
The calibration solution is the solution required for drawing the calibration curve of the analyzed elements. Its concentration range in the solution is expressed in micrograms per milliliter, which depends on the performance parameters and linear sensitivity of the instrument. At least 10 solutions are required to cover the measurement range (mass fraction) shown in Table 1.
8.4 Determination The ICP spectrometer shall first be initially adjusted, according to the manufacturer's recommendations and laboratory quantitative analysis operations.
Try to optimize the instrument parameters in each round as much as possible.
9.3 Standardization of calibration curve (drift correction)
The regular inspection and correction of the calibration curve shall be carried out as follows.
Take two calibration solutions, namely the one with the lowest and highest analyte content.
In the drawn calibration curve, the intensities of the two calibration solutions are measured; the correction coefficients alpha and beta are calculated according to formulas (4)
and (5).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
How to Buy GB/T 6730.63-2024
- 1Add to cart. Click the "Buy GB/T 6730.63-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6730.12-2016 — Iron ores - Determination of aluminium content - Chrome azurol S spectrophotometric method
GB/T 6730.13-2025 — Iron ores — Determination of calcium and magnesium content — EGTA-CyDTA titrimetric method
GB/T 6730.14-2017 — Iron ores—Determination of calcium content—Flame atomic absorption spectrometric method