GB/T 5686.5-2023Ferromanganese,ferromanganese-silicon,nitrogen-bearing ferromanganese and manganese metal—Determination of carbon content—The Infrared absorption method,the gasometric method,the gravimetric method and the coulometric method (English PDF)
锰铁、锰硅合金、氮化锰铁和金属锰 碳含量的测定 红外线吸收法、气体容量法、重量法和库仑法
This is a limited preview
Buy now to download the full PDF (32 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5686.5-2023 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 27, 2023
Implementation date
June 1, 2024
Scope
GB/T 5686.5-2023 is the English-translated version of 锰铁、锰硅合金、氮化锰铁和金属锰 碳含量的测定 红外线吸收法、气体容量法、重量法和库仑法.
GB/T 5686.5-2023 is Part 5 of GB/T 5686 and determines the carbon content of ferromanganese, ferromanganese-silicon, nitrogen-bearing ferromanganese and manganese metal.
It sets out four methods - infrared absorption after combustion in a high-frequency induction furnace under oxygen, the gasometric method with the carbon dioxide absorbed in potassium hydroxide solution, the gravimetric method, and the coulometric method using barium perchlorate solution - with the sieve size for each alloy and the precision data.
Clause 1 gives determination ranges of 0.010% to 10.00% for method 1, 0.40% to 5.00% for method 2, which is not applicable to nitrogen-bearing ferromanganese or manganese metal, 4.00% to 8.00% for method 3 on high carbon ferromanganese, and 0.010% to 0.40% for method 4 on manganese metal only.
It replaces GB/T 5686.5-2008, was issued on 27 November 2023 and has applied since 1 June 2024.
Found what you need?
Document preview — GB/T 5686.5-2023
National Standard of the People's Republic of China
- ICS
- 77.100
- Classification
- H 11
- Replacing
- GB/T 5686.5-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction6
- 1 Scope8
- 2 Normative references8
- 3 Terms and definitions9
- 4 Method 1.Infrared absorption method9
- 5 Method 2.Gasometric method14
- 6 Method 3.Gravimetric method19
- 7 Method 4.Coulometric method24
- 8 Test report28
- Appendix A (Normative) Sample analysis result acceptance procedure flowchart30
- Appendix B (Informative) Raw data of infrared absorption method precision test31
- Bibliography32
1 Scope
This document describes the determination of carbon content in ferromanganese, ferromanganese-silicon, nitrogen-bearing ferromanganese and manganese metal by the infrared absorption method, the gasometric method, the gravimetric method and the coulometric method.
This document is applicable to the determination of carbon content in ferromanganese, ferromanganese-silicon, nitrogen-bearing ferromanganese and manganese metal.
Determination range (mass fraction). 0.010% ~ 10.00% for method 1; 0.40% ~ 5.00% for method 2, not applicable to the determination of carbon content in nitrogen-bearing ferromanganese and manganese metal; 4.00% ~ 8.00% for method 3, applicable to the determination of carbon content in high carbon ferromanganese; 0.010% ~ 0.40% for method 4, only applicable to the determination of carbon content in manganese metal.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document.
GB/T 4010, Ferroalloys sampling and preparation of samples for chemical analysis
GB/T 6379.1, Accuracy (trueness and precision) of measurement methods and results - Part 1: General principles and definitions
GB/T 6379.2, Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
GB/T 8170, Rules of rounding off for numerical values & expression and judgment of limiting values
3 Terms and definitions
No terms and definitions need to be defined in this document.
4 Method 1.Infrared absorption method
4.1 Principle
Burn the sample in a high-frequency induction furnace with an oxygen flow. The carbon is converted into carbon dioxide and carried to the infrared absorption cell along with the oxygen flow. The infrared detector measures its absorption of infrared rays of a specific wavelength.
4.2 Reagents and materials
4.2.1 Acetone. the carbon content (mass fraction) of the residue after evaporation shall be less than 0.000 5%.
4.2.2 Anhydrous magnesium perchlorate, granular.
4.2.3 Caustic soda asbestos, granular.
4.2.4 Glass wool.
4.2.5 Tungsten particles, carbon content (mass fraction) less than 0.000 5%, particle size 0.8 mm ~ 1.4 mm.
4.2.11 Crucible tongs or long-handled tweezers.
4.3 Instruments and apparatuses
4.3.1 High-frequency infrared carbon and sulfur analyzer or infrared absorption carbon analyzer 4.3.1.1 High frequency infrared carbon and sulfur analyzer or infrared absorption carbon analyzer (sensitivity is 0.000 1%). The device connection diagram is shown in.
4.3.2 Air source system
4.3.2.1 The carrier gas system includes an oxygen cylinder, a two-stage pressure regulator and a timing control section to ensure the provision of appropriate pressure and rated flow.
4.3.2.2 The power gas source system includes power gas (4.2.9), a two-stage pressure regulator and a timing control section to ensure the provision of appropriate pressure and rated flow.
4.3.3 High frequency induction furnace
The melting temperature requirements of the sample shall be met.
4.3.4 Control system. […]
4.4 Sample taking
Collect and prepare samples in accordance with the provisions of GB/T 4010. The ferromanganese-silicon samples shall pass through a 0.125 mm sieve hole; the nitrogen-bearing ferromanganese samples shall pass through a 0.149 mm sieve hole; the manganese metal samples shall pass through a 0.177 mm sieve hole.
4.5 Procedure
4.5.1 Number of determinations
Make at least 2 independent determinations on the same sample.
4.5.3 Blank test
4.5.3.1 Ferromanganese-silicon. Weigh 0.40 g of pure iron (4.2.7) and place it in a ceramic crucible (4.2.10) pre-filled with 0.30 g of tin particles (4.2.6); cover it with 1.80 g of tungsten particles (4.2.5); measure according to 4.5.5. Repeat enough times; record the smallest and relatively stable three readings; calculate the average value and input it into the instrument. When measuring the sample, the instrument will automatically deduct the blank value.
4.5.4 Analysis preparation
4.5.5 Test calibration
4.5.6 Determination
4.5.6.1 According to the type and carbon content range of the sample to be tested, respectively select the best analytical conditions of the instrument, such as the combustion integration time of the instrument, the setting of the comparison level (or set number), etc.
4.6 Expression of analysis results
If the absolute value of the difference between two independent analysis results of the same sample is not greater than the repeatability limit (r), take the arithmetic mean as the analysis result.
4.7 Precision
The precision data of this document was determined in 2022 by nine laboratories which conducted joint tests on the carbon content in ferromanganese-silicon, ferromanganese, nitrogen-bearing ferromanganese and manganese metal of eight different levels. Each laboratory independently tested the sulfur content at each level three times (see Appendix B for the original data of the precision test) according to the statical methods in GB/T 6379.1 and GB/T 6379.2. The precision determined is shown in Table 2.
5 Method 2.Gasometric method
5.1 Principle
Preheat the sample in a tubular combustion furnace and burn with oxygen. Collect the generated carbon dioxide and other mixed gases in a gas measuring tube after desulfurization; then, use potassium hydroxide solution to collect the carbon dioxide, and measure the volume of the remaining gas. The difference in volume before and after absorption is the volume of carbon dioxide, which is then converted into carbon content.
5.2 Reagents and materials
5.2.10 Potassium hydroxide solution, 400 g/L.
5.2.11 Sodium chloride solution, 260 g/L. Use methyl red solution as the indicator, and add sulfuric acid solution (1+1) dropwise until it becomes acidic.
5.2.12 Oxygen, purity greater than 99.5%.
5.3 Instruments and apparatuses
5.3.1 Carbon meter using gasometric method
5.3.1.1 The carbon meter using gasometric method is shown in Figure 2.
5.3.1.2 Gas washing bottle, filled with sulfuric acid solution saturated with chromic acid (5.2.9).
5.3.1.3 Gas washing bottle, filled with soda lime or sodium hydroxide (5.2.3).
5.3.1.4 Drying tower, filled with activated alumina (5.2.4).
5.3.1.5 High temperature combustion tube, (23 mm ~ 24 mm) × 600 mm.
5.3.1.6 Tubular combustion furnace, adjustable current to ensure the required, temperature for burning the sample.
5.3.1.7 Asbestos fiber (5.2.2), burned until no carbon is left.
5.3.1.8 Desulfurization tube, filled with active manganese dioxide (5.2.5).
5.3.1.11 Absorber, containing potassium hydroxide solution (5.2.10)
5.3.1.12 Small piston, one side ventilated to the atmosphere.
5.3.2 Long hook
Made of low carbon nickel-chromium wire or heat-resistant alloy wire.
5.4 Sample taking
Collect and prepare samples in accordance with the provisions of GB/T 4010.
Ferromanganese-silicon and ferromanganese with medium and high carbon content shall all pass through the 0.125 mm sieve hole; ferromanganese with low carbon content shall all pass through the 0.149 mm sieve hole.
5.5 Procedure
5.5.1 Number of determinations
Make at least 2 independent determinations on the same sample.
6 Method 3.Gravimetric method
6.1 Principle
Burn the sample in an oxygen flow at 1 200 °C ~ 1 350 °C. The generated carbon dioxide is carried into the absorption bottle by oxygen and absorbed by the caustic soda asbestos. Measure the weight gain of the caustic soda asbestos, which is the content of carbon dioxide generated; then, convert into carbon content. The main reaction formula is as follows. […]
6.2 Reagents and materials
6.2.8 Sulfuric acid solution saturated with chromic acid. Add potassium dichromate or chromic anhydride to sulfuric acid (6.2.7) until it is saturated and use the above-part clear solution.
6.3 Instruments and apparatuses
6.3.1 Carbon meter using gravimetric method
6.3.1.2 Oxygen cylinder, provided with pressure regulating valve.
6.3.1.3 Reforming furnace, equipped with a combustion tube filled with platinum asbestos, the furnace temperature is maintained at 625 °C.
6.3.1.4 U-shaped tube for drying and purifying oxides (see 4 in Figure 3), filled with anhydrous magnesium perchlorate (6.2.2) and caustic soda asbestos (6.2.5) and is separated by glass fiber. The diameter of the U-shaped tube is not less than 25 mm and the height is not less than 100 mm.
6.3.1.5 Tubular combustion furnace, adjustable current to ensure the required, temperature for burning the sample.
6.3.1.6 High temperature combustion tube, (23 mm ~ 24 mm) × 600 mm.
6.3.1.7 Porcelain boat, 88 mm or 97 mm in length, shall be preliminarily burned in a […]
6.4 Sample taking
Collect and prepare samples in accordance with the provisions of GB/T 4010. The samples shall pass through a 0.149 mm sieve.
6.5 Procedure
6.5.1 Number of determinations
Make at least 2 independent determinations on the same sample.
6.5.2 Sample mass
Weigh the sample and flux according to Table 5, with the sample accurate to 0.000 1 g and the flux accurate to 0.01 g.
6.5.3 Blank test
Carry out a blank test along with the sample.
6.5.4 Analysis preparation
Connect the carbon meter using gravimetric method; raise the furnace temperature to 1 200 °C ~ 1 350 °C; check the airtightness of the instrument and the oxygen purification effect; introduce oxygen at a rate of 300 mL/min ~ 500 mL/min. After 15 min ~ 20 min, remove the absorption bottle (see 12 in Figure 3); weigh it at room temperature; put it back.
6.5.6 Result calculation
Calculate the carbon content in the sample according to Formula (3).
7 Method 4.Coulometric method
7.1 Principle
Burn the sample in the oxygen flow of a high-frequency induction heating furnace. The generated carbon dioxide is absorbed by a barium perchlorate solution with a known pH value. The generated perchloric acid changes the pH value of the solution. Pass a pulse current of a certain amount of electricity through the solution for electrolysis to restore the pH value of the solution to its original value. Calculate the carbon content in the sample based on the pulse electricity consumed in the electrolysis.
7.2 Reagents and materials
7.2.1 Barium carbonate, powder.
7.2.2 Cotton wool.
7.2.3 Glass wool.
7.2.4 Sodium hydroxide.
7.3 Instruments and apparatuses
7.3.1 Carbon meter using coulometric method
7.3.1.1 The carbon meter using coulometric method is shown in Figure 5.
7.3.1.2 Gas washing bottle (see 5 in Figure 5), containing sulfuric acid (rho = 1.84 g/mL).
7.3.1.3 Gas washing bottle (see 6 in Figure 5), containing potassium hydroxide solution (400 g/L).
7.3.1.4 Gas washing bottle (see 7 in Figure 5), containing potassium dichromate saturated sulfuric acid solution (7.2.9).
7.3.2 High frequency induction heating furnace
The output power is not less than 2 kW.
7.3.3 Power regulator
The power is 3 kW.
7.3.4 Oxygen cylinder
Equipped with a pressure reducing valve with flow meter.
7.3.5 Crucible
The size is phi25 mm × 25 mm, and it is burned in a high-temperature heating furnace above 1 200 °C for 4 h or burned with oxygen until the blank value is the lowest.
7.4 Sample taking
Collect and prepare samples in accordance with the provisions of GB/T 4010. The samples shall all pass through a 0.177 mm sieve.
7.5 Procedure
7.5.1 Number of determinations
Make at least 2 independent determinations on the same sample.
7.5.2 Sample mass
Weigh 0.500 g of sample, accurate to 0.000 1 g.
7.5.3 Blank test
Carry out blank tests several times with the sample and take the average value as the blank value. The blank value calculated based on 0.50 g sample shall not be greater than 0.005%.
7.5.4 Analysis preparation
7.5.5 Determination
Place the sample (see 7.5.2) in a crucible (7.3.5) and cover it with 1.5 g of tungsten granules (7.2.6), 0.3 g of pure iron (7.2.8) and 0.3 g ~ 0.5 g of tin granules (7.2.7).
After the instrument is normal, control the oxygen flow rate to 200 mL/min ~ 300 mL/min; press the "electrolysis" and "self-reset" switches; close the piston leading to the absorption cup; put down the furnace tube sealing bolt support; place the crucible (7.3.5) on the support seat inside the high-frequency induction heating furnace (7.3.2);
8 Test report
The test report shall include the following contents. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 32 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4010Ferroalloys sampling and preparation of samples for chemical analysis
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
Similar standards
Editions of GB/T 5686.5
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 5686.5-2023 | Ferromanganese,ferromanganese-silicon,nitrogen-bearing ferromanganese and manganese metal—Determination of carbon content—The Infrared absorption method,the gasometric method,the gravimetric method and the coulometric method | current edition | Current |
| GB/T 5686.5-2008 | Ferromanganese,ferromanganese-silicon,nitrogen-bearing ferromanganese and manganese metal—Determination of carbon content—The Infrared absorption method,the gasometric method,the gravimetric method and the coulometric method | previous edition | Superseded |
This page sells the current edition, GB/T 5686.5-2023. Earlier editions are listed for reference only.
How to Download GB/T 5686.5-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4010-2015 — Ferroalloys sampling and preparation of samples for chemical analysis
GB/T 40100-2021 — Life cycle assessment method for electric machine
GB/T 40101-2021 — Ultrasonic testing method for stainless steel bars, plates and forgings of PWR nuclear fuel assembly and associated assembly
Secure payment via Stripe
Payments accepted
GB/T 5686.5-2023
$360.00