Scope
GB/T 5516-2011 is the English-translated version of 粮油检验 粮食运动粘度测定 毛细管粘度计法.
GB/T 5516-2011 is the Chinese standard "Inspection of grain and oils - Determination of viscosity of grain - Capillary viscometer method".
Its scope clause reads: This standard specifies the determination of food kinematic viscosity using capillary viscometer terms and definitions, principle, reagents, instruments and equipment, the operation step Suddenly, results calculation and representation.
This standard applies to the determination of rice, wheat and maize kinematic viscosity. Its clauses include terms and definitions; reagents; instruments and equipment.
Found what you need?
Document preview — GB/T 5516-2011
National Standard of the People's Republic of China
- ICS
- 67.060
- Classification
- B 20
- Replacing
- GB/T 5516-1985
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 5 Reagents
- 6 instruments and equipment
1 Scope
This standard specifies the determination of food kinematic viscosity using capillary viscometer terms and definitions, principle, reagents, instruments and equipment, the operation step
Suddenly, results calculation and representation.
This standard applies to the determination of rice, wheat and maize kinematic viscosity.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 1354-2009 rice
GB 5491 grain and oilseeds testing for sampling, and sample method
GB/T 5497 grain and oilseeds - Determination of water test
Laboratory use specifications and test methods GB/T 6682 Analysis
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1 Kinematic viscosity viscosity
Fluid under gravity flow measurement of internal friction. A ratio of dynamic viscosity to its density at the same temperature of the fluid representation.
Principle 4
Quantitative gauging water added to the sample at a specific temperature gelatinization gelatinization measured liquid flows by gravity through the capillary of time. Sample pasting
Kinematic viscosity and fluid flow through the capillary pasting proportional to the time.
5 Reagents
Test water should comply with GB/T 6682 in the three water requirements.
6 instruments and equipment
6.1 constant temperature water bath
the water tank, electric control and temperature control devices, timers, the control and accuracy of temperature 50 °C ± 0.1 °C, timing
Minimum reading 0.1s.
6.2 Pasting apparatus
the pasting, heating mantle and temperature control, timing device components. Pasting consists pasting bottle (volume 500mL) and condensing units
Composition; heating mantle power 200W, volume 500mL; temperature control, timing system can be controlled so that the heating temperature was kept pasting pasting bottle micro-boiling,
Automatic alarm after 30min.
6.3 capillary viscometer
aperture 0.8mm, 1.0mm, 1.2mm, 1.5mm, with a viscometers viscosity constant calibration certificate. Should be selected together
Suitable aperture constant and viscosity to pasting the measuring liquid flow in the 30s ~ 60s time is appropriate, not more than 90s and less than 20s.
NOTE. capillary viscometer configuration diagram in Appendix A.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of GB/T 5516
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 5516-2011 | Inspection of grain and oils - Determination of viscosity of grain - Capillary viscometer method | current edition | Current |
| GB/T 5516-1985 | Inspection of grain and oils - Determination of viscosity of grain - Capillary viscometer method | previous edition | Superseded |
This page sells the current edition, GB/T 5516-2011. Earlier editions are listed for reference only.
How to Download GB/T 5516-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 5516-2011
$105.00