GB/T 5275.8-2014Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 8: Diffusion method (English PDF)

气体分析 动态体积法制备校准用混合气体 第8部分:扩散法

Preview PDF

This is a limited preview

Buy now to download the full PDF (10 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5275.8-2014 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

July 8, 2014

Implementation date

December 1, 2014

Scope

GB/T 5275.8-2014 is the English-translated version of 气体分析 动态体积法制备校准用混合气体 第8部分:扩散法.

GB/T 5275.8-2014 — This section provides diffusion prepared by mole fractions within the range of 10-9 to 10-3 in the calibration gas mixtures dynamic method. The party Law relative expanded uncertainty U, whose value does not exceed ± 2%, the combined standard uncertainty multiplied by a coverage factor (k = 2) obtained.

If the source line diffusion and use of location between the very short, the diffusion method can be used to prepare a boiling point at room temperature within a range of 40 °C ~ 160 °C for Low-Level Calibration liquid organic component gas mixtures.

This section provides the diffusion method, not only for the preparation of the atmospheric environment and indoor air concentrations corresponding to a variety of hydrocarbons calibration mix Combined gas, a mixed gas of water is also applicable to the preparation of low concentration.

Found what you need?

Document preview — GB/T 5275.8-2014

National Standard of the People's Republic of China

ICS
71.040.40
Classification
G 86

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references

Foreword

GB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is divided into the following sections.

--- Part 1. calibration method;

--- Part 2. positive displacement pump;

--- Part 4. continuous injection;

--- Part 5. Capillary calibration devices;

--- Part 6. Critical orifices;

--- Part 7. Thermal mass flow controller;

--- Part 8. Diffusion method;

--- Part 9. Saturation method;

--- Part 10. Permeation;

--- Part 11. Electrochemical method occurs.

This section GB/T 5275 Part 8.

This section drafted in accordance with GB/T 1.1-2009 given rules.

This section uses the translation method identical with ISO 6145-8:2005 "gas analysis dynamic volume Preparation of calibration gas mixtures 8th Part I. diffusion method. " Consistency correspondence between this part of international documents and normative references of our files are as follows.

--- GB/T 5275.7-2014 gas analysis dynamic volume Preparation of calibration gas mixtures - Part 7. Thermal mass flow Volume controllers (ISO 6145-7:2009, IDT).

This part is proposed by the China Petroleum and Chemical Industry Association.

This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized.

This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute Limited, a Shanghai Song chemical gas the company.

1 Scope

This section provides diffusion prepared by mole fractions within the range of 10-9 to 10-3 in the calibration gas mixtures dynamic method. The party Law relative expanded uncertainty U, whose value does not exceed ± 2%, the combined standard uncertainty multiplied by a coverage factor (k = 2) obtained.

If the source line diffusion and use of location between the very short, the diffusion method can be used to prepare a boiling point at room temperature within a range of 40 °C ~ 160 °C for Low-Level Calibration liquid organic component gas mixtures.

This section provides the diffusion method, not only for the preparation of the atmospheric environment and indoor air concentrations corresponding to a variety of hydrocarbons calibration mix Combined gas, a mixed gas of water is also applicable to the preparation of low concentration.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

ISO 6145-7 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 7. Thermal mass flow controllers (Gas analysis-Preearationofcalibrationgasmixturesusingdynamicvolumetricmethods-Part 7. Thermal mass-flowcontrolers) Principle 3 After appropriate calibration component dimensions (length, diameter) of the diffuser diffusion into the gas mixture to be prepared in the carrier gas stream. Container has been charged with Known high purity liquid calibration component as a component vapor source, mounted vertically on the container the diffuser. The device (cell proliferation) is placed in a constant Bath temperature, the bath was a known constant flow rate carrier gas purge of high purity (Figure 1). The composition of the mixed gas diffusion by the calibration component Mass flow and carrier gas flow rate determination.

Diffusion mass flow calibration component depends on the principle.

--- Calibration component in a carrier gas diffusion coefficient;

--- Calibration component vapor pressure at bath temperature;

--- Diffusion tube size.

By diffusion tubes were placed on a magnetic levitation microbalance continuous weighing, or through other periodic weighing microbalance, accurately Measuring the mass flow rate of diffusion. Determination will affect the calibration component (instantaneous) mass flow uncertainty.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 5275.8-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5275.8-2014

$235.00