GB/T 44989-2024Evaluation for green data center (English PDF)
绿色数据中心评价
Open the GB/T 44989-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF (25 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 28, 2024
Implementation date
June 1, 2025
Scope
GB/T 44989-2024 is the English-translated version of 绿色数据中心评价.
GB/T 44989-2024 is the Chinese evaluation standard for green data centres. Data centres are now a named target of Chinese energy policy, with binding PUE ceilings in the eastern hub cities and a national programme moving computing westward to where the power is renewable, and that policy needs a single method of scoring a facility rather than the several competing schemes that preceded it. The standard sets the rating levels, the evaluation indicators - energy efficiency, water use, renewable energy share, resource utilisation, carbon, and the operational management behind them - and the evaluation method by which a centre is scored and graded. Normative annexes set the qualification requirements for third-party evaluation bodies and the calculation methods for the load utilisation rate of the information equipment, for the water resource utilisation efficiency, and for the index evaluation itself. It takes effect on 1 June 2025.
Document preview — GB/T 44989-2024
National Standard of the People's Republic of China
- ICS
- 35.020
- Classification
- L60
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Rating2
- 5 Evaluation indicators3
- 12 Reference21
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed and coordinated by the National Information Technology Standardization Technical Committee (SAC/TC28). This document was drafted by: China Electronics Technology Standardization Institute, Shenzhen Tencent Computer Systems Co., Ltd., Runze Technology Development Co., Ltd. Ltd., Sugon Data Infrastructure Innovation Technology (Beijing) Co., Ltd., Kehua Data Co., Ltd., Beijing AVIC Beijing Runke Technology Co., Ltd., China Mobile Communications Group Design Institute Co., Ltd., China Science and Technology (Beijing) Technology Co., Ltd., Beijing Tonghe Shiyi Telecom Technology Co., Ltd. Institute of Science and Technology Co., Ltd., Nanjing Jialitu Computer Room Environment Technology Co., Ltd., Zhejiang Yizhou Electronic Technology Co., Ltd., Yimikang Technology Group Co., Ltd., Beijing Power Exchange Co., Ltd., National Energy Conservation Center, Inspur Electronic Information Industry Co., Ltd. Ltd., State Grid Digital Technology Holdings Co., Ltd., Qinghai Provincial Development and Reform Commission, Guizhou Xiangming Technology Co., Ltd., Huawei Technologies Co., Ltd., Beijing Zhenshitong Technology Co., Ltd., Shenzhen Kstar Technology Co., Ltd., Zhejiang Post and Telecommunications Engineering Construction Co., Ltd. Ltd., Xinshangpin Technology Industry Co., Ltd., Beijing Ehualu Information Technology Co., Ltd., Zhongguancun Xiezhong Chuangzhi Information Industry Promotion Association, Shenzhen Qianhai Energy Technology Development Co., Ltd., Hangzhou Wantai Certification Co., Ltd., Beijing Kejitong Electronic Engineering Co., Ltd., Beijing Zhongwang Digital Information Technology Research Institute Co., Ltd., Guangdong Shenling Environmental Systems Co., Ltd., China Electronics Technology Standardization Institute East China Branch, Beijing Yunxingyu Transportation Technology Co., Ltd., Super Fusion Digital Technology Co., Ltd., China National Institute of Metrology, China National Petroleum and Natural Gas Co., Ltd. Exploration and Development Research Institute, China Mobile Communications Group Hebei Co., Ltd., China Communications Construction Co., Ltd., China Construction Standards Design and Research Institute Co., Ltd., China United Network Communications Co., Ltd. Shijiazhuang Branch, Hubei Huazhong Electric Power Technology Development Co., Ltd. Shanghai Energy Efficiency Center (Shanghai Industrial Green Development Promotion Center), Beijing Digital Science and Technology Co., Ltd. Technology Co., Ltd., Haitong Securities Co., Ltd., Zhejiang Datacenter Data Technology Co., Ltd., Lanzhou University of Technology, China Life Insurance Co., Ltd. Shanghai Data Center of China Southern Power Grid Co., Ltd., China Southern Power Grid Big Data Service Co., Ltd., GDS Services Co., Ltd., Jiangxi Pacific Cable Group Group Co., Ltd., Jiangxi Meiyuan Cable Group Co., Ltd., Jietong Smart Technology Co., Ltd., and Softcom Information Technology (Group) Co., Ltd. Co., Ltd., Shenzhen Humeng Technology Co., Ltd., Hangzhou Hanggang Cloud Computing Data Center Co., Ltd., Guangzhou Haote Energy Saving and Environmental Protection Technology Limited by Share Ltd. The main drafters of this document are. Zhang Junhua, Xiao Li, Li Li, Fan Juan, Chen Xiao, Leng Biao, Liu Yu, Gao Shuchen, Jin Chi, Gao Peng, Lin Li, Zhu Xiaozhou, Xu Haijin, Ju Chengzong, Zhu Jing, Li Meng, Zhang Xian, Yang Shaopeng, Li Jinbo, Li Da, Liu Haishan, Huang He, Lü Yixing, Zheng Wei, Shen Wenyi, Ding Chunfeng, Liu Hong, Dai Wei, Wang Xijiang, Niu Chuan, Zhang Xuebin, Wang Zhaohui, Jiang Zhongwei, Fan Chaoyang, Guo Kai, Huang Qunji, Zhao Yongxiang, Chen Gang, Yu Linglin, Xiao Tianli, Yan Wang, Zhang Xin, Huang Xuan, Wu Tong, Yu Qingyou, Chen Ce, Liu Yibin, Wu Yan, Chen Yue, Zhang Chaoyang, Jia Gengsheng, Huang Bo, Liu Yu, Qin Hongbo, Huang Chao, Zhang Hao, Qian Zhiqiang, Chen Shi, Chen Wei, Xiang Yongtao, Liu Jiatong, Guo Junfeng, Yu Zhi, Lu Yunli, Xia Tinghao, Liu Ximing, Liu Yun, Wang Chunyuan, Wang Jingbo, Li Xuliang and Chen Zhenming. Green Data Center Evaluation
1 Scope
GB/T 44989-2024 is the Chinese evaluation standard for green data centres. Data centres are now a named target of Chinese energy policy, with binding PUE ceilings in the eastern hub cities and a national programme moving computing westward to where the power is renewable, and that policy needs a single method of scoring a facility rather than the several competing schemes that preceded it. The standard sets the rating levels, the evaluation indicators - energy efficiency, water use, renewable energy share, resource utilisation, carbon, and the operational management behind them - and the evaluation method by which a centre is scored and graded. Normative annexes set the qualification requirements for third-party evaluation bodies and the calculation methods for the load utilisation rate of the information equipment, for the water resource utilisation efficiency, and for the index evaluation itself. It takes effect on 1 June 2025.
This document establishes the green data center evaluation level and specifies the evaluation indicators and methods. This document applies to the construction, operation, maintenance, transformation and evaluation of green data centers.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.
GB 17167 General rules for the allocation and management of energy metering instruments in energy-consuming units
GB/T 18870 General technical requirements for water-saving products
GB/T 26572 Limit requirements for restricted substances in electronic and electrical products
GB/T 32910.4-2021 Data center resource utilization Part
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Data Center It consists of computer sites (computer rooms), other infrastructure, information system hardware and software, information resources (data) and personnel, as well as corresponding regulations. An entity composed of degrees. [Source: GB/T 32910.1-2017, 2.1]
3.2 Green Data Center Green Data Center During the entire life cycle, under the conditions of ensuring the safety of personnel and the safe, stable and reliable operation of information systems and their supporting equipment, the A data center that saves energy resources and reduces negative environmental impact.
3.3 Renewable energy A type of primary energy that is, to a certain extent, regenerated on Earth by natural processes.
Note. This type of energy includes solar energy, hydropower, wind energy, biomass energy, ocean energy and geothermal energy. [Source: GB/T 32910.1-2017, 2.7, modified]
3.4 Water sources different from traditional surface water supply and groundwater supply include recycled water, rainwater, seawater, etc.
4 Renewable energy utilization rate
GB 40879-2021 Data center energy efficiency limit values and energy efficiency grades
GB/T 42581 Information Technology Service Data Center Business Continuity Rating Evaluation Criteria
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 17167General rules for energy measuring instrument equipping and managing of energy user
- GB/T 18870Technical conditions for water saving products and general regulation for management
- GB/T 26572Requirements of concentration limits for certain restricted substances in electrical and electronic products
- GB/T 32910.4-2021Data center—Resource utilization—Part 4: Renewable energy factor
- GB 40879-2021Maximum allowable values of energy efficiency and energy efficiency grades for data centres
- GB/T 42581Information technology service - Evaluation criteria for data center business continuity
Similar standards
GB 38031-2025|GB/T44989-2024|GB/T 1.1-2020|GB 17167|GB/T 18870|GB/T 26572|GB/T 32910.4-2021|GB 40879-2021
How to Buy GB/T 44989-2024
- 1Add to cart. Click the "Buy GB/T 44989-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17167-2025 — General rules for energy measuring instrument equipping and managing of energy user
GB 40879-2021 — Maximum allowable values of energy efficiency and energy efficiency grades for data centres
GB/T 18870-2011 — Technical conditions for water saving products and general regulation for management