Scope

GB/T 44386-2024 is the English-translated version of 轨道交通 机车车辆 车载牵引锂离子电池.

GB/T 44386-2024 is the Chinese national standard for the lithium-ion traction batteries carried on rail vehicles to supply traction power on hybrid rolling stock.

It sets the structure of the battery system, from cells and modules to the mandatory battery management system and the optional thermal management system, the conditions of use including ambient temperature class T1 from -25 °C to +40 °C and the shock and vibration of GB/T 21563-2018, the safety, electrical, mechanical and performance requirements, the nameplate and model designation, and the tests with their measurement tolerances.

It leaves out auxiliary-supply batteries, converters, inductors, capacitors and switchgear, and hybrid storage combining two technologies. Rolling stock builders and battery makers use it at design and acceptance.

Modified from IEC 62928:2017, it was issued on 31 December 2024 and has applied since 1 July 2025.

Found what you need?

Document preview — GB/T 44386-2024

National Standard of the People's Republic of China

ICS
29.280

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions7
  • 4 Abbreviations14
  • 5 Battery system structure15
  • 6 Parameter measurement error18
  • 7 Conditions of use19
  • 8 Models and marks20
  • 9 Safety requirements22
  • 10 Dimensions24
  • 11 Electrical requirements25
  • 12 Mechanical requirements26
  • 13 Performance requirements27
  • 14 Storage and transportation conditions29
  • 15 Tests29
  • Annex A (informative) List of technical differences and their reasons48
  • Annex B (informative) Examples of battery system configurations51
  • Annex C (normative) Documents supplied with the product56
  • Annex D (informative) Examples of parameter ranges for other high-power cycling tests57
  • Bibliography58

1 Scope

This document specifies the design, operating parameters, safety requirements, data exchange, exit-factory and type inspections, as well as model designations and marks, for onboard lithium-ion traction batteries used in rail transit rolling stock. It also describes the corresponding test methods.

This document applies to onboard lithium-ion traction batteries for rail transit rolling stock.

The battery system referred to in this document is an energy storage system serving as the traction power source for rail transit rolling stock - such as the hybrid vehicles defined in IEC 62864-1:2016 - and does not include lithium-ion batteries used for auxiliary power supplies.

Sub-components within the battery system, such as the battery management system and the battery thermal management system, are also included in this document.

Power conversion equipment (such as choppers, converters, etc.), inductors, capacitors, and switchgear are outside the scope of this document.

General requirements for onboard energy storage systems are specified in IEC 62864-1:2016.

This document specifically specifies lithium-ion battery technology, but does not preclude the use of technologies other than lithium-ion battery technology for traction battery applications.

Hybrid energy storage systems that utilize two or more energy storage technologies - such as traction batteries and electric double-layer capacitors - fall outside the scope of this document. However, if different energy storage system technologies are employed on the same train and managed independently, each individual energy storage system must comply with its respective standards.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references,

NOTE: There are no technical differences between the cited content of GB/T 31523.1-2015 and that of ISO 7010:2011.

GB/T 32347.1-2015, Railway applications -- Environmental conditions for equipment -- Part 1: Equipment on board rolling stock (IEC 62498-1:2010, MOD)

NOTE: There are no technical differences between the cited content of GB/T 32347.1-2015 and that of IEC 62498-1:2010.

GB/T 32350.1, Railway applications -- Insulation coordination -- Part 1: Basic requirements -- Clearances and creepage distances for all electrical and electronic equipment (GB/T 32350.1-2015, IEC 62497-1:2010, MOD)

GB 38031, Electric vehicles traction battery safety requirements

GB/T 38661-2020, Technical specifications of battery management system for electric vehicles ISO/IEC GUIDE 51, Safety aspects -- Guidelines for their inclusion in standards

IEC 62619:2022, Secondary cells and batteries containing alkaline or other nonacid electrolytes -- Safety requirements for secondary lithium cells and batteries, for use in industrial applications

IEC 62620:2014, Secondary cells and batteries containing alkaline or other non - acid electrolytes -- Secondary lithium cells and batteries for use in industrial applications

IEC 62864-1:2016, Railway applications -- Rolling stock -- Power supply with onboard energy storage system -- Part 1: Series hybrid system

3 Terms and definitions

For the purposes of this document, the terms and definitions defined in GB/T 2900.41-2008, GB/T 2900.36, and ISO/IEC GUIDE 51, as well as the followings apply.

3.1 Charge retention

capacity retention The ability of a battery system to retain its capacity in an open-circuit state under specified conditions. [Source: GB/T 2900.41-2008, 482-03-35, modified]

3.2 Self discharge

The phenomenon in which energy from a cell or battery system is lost through means

3.35 End of life

The battery system fails to meet the functions or operating modes originally agreed upon by the user/integrator and the manufacturer.

NOTE: Internal resistance or capacity can serve as parameters for end-of-life. [Source: IEC 62864-1:2016, 3.1.15, modified]

3.36 Beginning of life

The rated capacity or fully usable energy of the battery system at the time of delivery by the manufacturer serves as the minimum performance level. [Source: IEC 62864-1:2016, 3.1.16, modified]

3.37 Down time of battery system

The time interval during which the battery system is not in the traction operation state.

NOTE: Down time includes idle time, maintenance time, time spent in the depot, transit time, etc.

4 Abbreviations

The following abbreviations apply to this document.

BMS. Battery Management System

BOL. Beginning of Life

BTMS. Battery Thermal Management System

EOL. End of Life

ESS. Energy Storage System

ESU. Energy Storage Unit

PPS. Primary Power Source

SOC. State of Charge

SOE. State of Energy

SOH. State of Health

5 Battery system structure

5.1 Battery system

A battery system consists of components such as cells, cell blocks, packs, and subsystems (e.g., BMS, BTMS). Battery systems can be configured in various ways.

Subsystems may be located outside the battery enclosure - for instance, within the traction inverter.

The battery enclosure is a component directly accessible to the user. The battery system may be distributed across multiple battery enclosures (multiple mechanical housings).

Some enclosures may not contain cells (e.g., those housing distributed BMS components).

Referring to Figure 4 of IEC 62864-1:2016, the ESU is treated as a component of the ESS within the train's series hybrid system.

The functional configuration of the battery system is shown in Figure 1. The BMS is mandatory, while the BTMS is optional.

In accordance with IEC 62864-1:2016, the system levels are defined as follows.

a) Level 1.Vehicle/system interface.

b) Level 2.System and interface. c) Level 3.Component. d) Level 4.Sub-component.

- disconnecting or isolating the battery pack and battery branches if abnormal operating parameters are detected;

- calculating battery SOC, etc., based on data obtained from monitoring functions;

- communicating data externally with the battery system (for systems with independent safety functions, brief interruptions in communication are permitted within the timeframes specified in the product documentation as per Annex C);

- managing cells or battery packs/modules to ensure voltage or SOC balancing;

NOTE: Power balancing among multiple ESUs is performed by the upper-level system.

- controlling the internal environment of the battery system (optional function), such as air conditioning (temperature, humidity), which may include a BTMS.

In some cases, certain functions of the BMS can be integrated into other systems, such as traction inverters, vehicle control units, and passive battery balancing modules.

5.4 BTMS

The BTMS is an optional sub-component used to maintain the temperature of the battery pack or battery module, ensuring defined performance and service life under specified operating modes. The BTMS may include the following functions.

- monitoring the temperatures of the battery, cooling medium, environment, etc.;

- controlling cooling and/or heating equipment;

- communicating BTMS data with external systems.

Cooling equipment, such as cooling fans, can be installed inside or outside the battery enclosure, or within the traction cooling system.

6 Parameter measurement error

Sources of error include measuring instruments, measurement methods, and all sources of error arising during the testing process.

Unless otherwise specified, the accuracy of the test and measurement instruments and equipment in this document shall meet the requirements of Clause 4 of IEC 62620:2014.

a) Voltage. ±0.5%;

b) Current. ±1%;

c) Temperature. ±2 K;

d) Time. ±0.1%; e) Dimensions. ±1%.

For detailed specifications regarding the selection of instruments, refer to the section on analog instruments in GB/T 7676 (all parts). Details of the instruments used shall be provided in the test report.

7 Conditions of use

7.1 General requirements

The operating conditions for electrical equipment on rolling stock shall comply with the requirements of GB/T 21413.1. Requirements for other special conditions shall comply with the relevant product standards.

7.2 Mechanical conditions

The battery system shall be capable of withstanding the shock and vibration specified in GB/T 21563-2018.

7.3 Environmental conditions

7.3.1 General requirements

Environmental conditions shall comply with the relevant provisions of IEC 62864-1:2016, GB/T 21413.1, and GB/T 32347.1-2015.

7.3.2 Ambient temperature

The ambient temperature shall comply with the requirements for class T1 specified in GB/T 32347.1-2015. The temperature range is -25°C ~ +40°C, representing the air temperature range outside the rolling stock.

If required, the user/integrator may specify a temperature range higher or lower than the requirements stated above.

7.3.3 Operating temperature

The operating temperature range of the internal components of the battery system shall comply with the provisions of Column (2) or Column (3) of Table 2 in GB/T 32347.1-2015.

7.3.4 Temperature for service life calculation

The reference temperature for service life calculation shall be the TR1 reference temperature specified in Table 3 of GB/T 32347.1-2015. Generally, this refers to the ambient air temperature. For battery systems installed in battery enclosures, the reference temperature shall account for the temperature rise of the air inside the enclosure, based on system cooling conditions (such as the operation of the Battery Thermal Management System, or BTMS).

If other temperature-related service life specifications are required, an ambient temperature histogram provided by the user or integrator shall be used.

7.4 Electrical conditions

7.4.1 Traction circuit

The voltage range of battery systems directly or indirectly connected to the traction circuit shall comply with the provisions of GB/T 1402.

The voltage of the pull-up circuit connected to the in-vehicle PPS shall be determined in accordance with the PPS specifications.

7.4.2 Control circuit

If the power supply for the battery system control circuit is derived from outside the battery system, the control voltage shall comply with the requirements of GB/T 21413.1.

The electronic circuits of the BMS shall comply with the requirements of GB/T 25119.

7.4.3 Insulation coordination

Clearance, creepage distance, and insulation voltage shall comply with the provisions of GB/T 32350.1.

The dielectric test results of the equipment shall comply with the provisions of GB/T 21413.1.

7.5 Electromagnetic compatibility

The electromagnetic compatibility of the battery system shall comply with the provisions of GB/T 24338.4.

7.6 Software

The BMS software structure and verification shall comply with the provisions of GB/T 28808 and GB/T 21562.

8 Models and marks

8.1 Nameplate

The nameplate of the battery system or each separable battery enclosure shall be placed on a surface that is easily visible and accessible. The nameplate shall not easily detach or be lost.

NOTE: For the requirements regarding the battery enclosure, see 5.1. The information on the nameplate shall include.

- Lithium-ion battery or lithium battery (if applicable);

- Manufacturer's name or identification;

- Date of manufacture (date may be specified, if possible);

- Unique serial number of the complete battery system (separate enclosures shall have their own unique serial numbers);

- Name (see 8.2);

- Nominal voltage (if applicable);

- Rated capacity or calculated rated capacity (see final paragraph) (if applicable);

- Mass;

- Cooling method;

- Version (if applicable);

- Part number of the complete battery system or any separate components.

If the test object is a disconnection unit of a battery system, the system's rated capacity shall be calculated and stated using a reasonable method.

8.2 Names for cells and battery systems

Cells shall be named in the following format.

NOTE 1: See 5.2 in IEC 62620:2014.

Battery packs/modules and battery systems shall be named in the following format.

NOTE 2: See 5.3 in IEC 62620:2014. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 58 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 44386-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation.

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
58 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 44386-2024

$560.00