Scope

GB/T 4325.1-2013 is the English-translated version of 钼化学分析方法 第1部分:铅量的测定 石墨炉原子吸收光谱法.

GB/T 4325.1-2013 is the Chinese standard "Methods for chemical analysis of molybdenum - Part 1: Determination of lead content - Graphite furnace atomic absorption spectrometry".

Its scope clause reads: GB/T 4325 This section specifies the method for determination of molybdenum in lead content. This section applies to molybdenum trioxide, ammonium molybdate, molybdenum powder, molybdenum bar of lead contents.

Measurement range. 0.0001% to 0.0100%. Its clauses include method summary; reagents; instrument.

Found what you need?

Document preview — GB/T 4325.1-2013

National Standard of the People's Republic of China

ICS
77.120.99
Classification
H 63
Replacing
GB/T 4325.1-1984

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Method summary
  • 3 Reagents
  • 4 Instrument

1 Scope

GB/T 4325 This section specifies the method for determination of molybdenum in lead content.

This section applies to molybdenum trioxide, ammonium molybdate, molybdenum powder, molybdenum bar of lead contents. Measurement range. 0.0001% to 0.0100%.

2 Method summary

Sample was dissolved hydrogen peroxide. In nitric acid medium with argon as a protective gas, graphite furnace atomic absorption spectrometer wavelength 283.3nm

Lead measured absorbance.

3 Reagents

Unless otherwise indicated, this part of water as a secondary water or water for more than two. The reagents were used pure class distinctions.

3.1 paramolybdate

mass fraction >=99.99%.

3.2 molybdenum substrate

(wPb<=0.000005%).

3.3

nitric acid (rho = 1.42g/mL).

3.4

Hydrogen peroxide (rho = 1.10g/mL).

3.5

nitric acid (11).

3.6 lead standard stock solution

Weigh 0.1000g metallic lead (wPb>=99.99%) in 250mL beaker, covered table dish, add

30mL of nitric acid (3.5), dissolved by heating, cooling, transferred to 1000mL volumetric flask, dilute with water to volume, and mix. This solution containing 1mL

100µg lead.

3.7 Lead standard solution

Pipette 1.00mL lead standard stock solution (3.6) in 100mL volumetric flask, dilute with water to volume, and mix.

This solution 1mL containing 1µg lead.

3.8 Argon

volume fraction of greater than 99.99%.

4 Instrument

Graphite furnace atomic absorption spectrometer, with a lead hollow cathode lamp.

Under optimum working conditions for those who can reach the following indicators can be used.

--- Characteristic concentration. the test solution and measurement matrix consistent solution, characteristic concentration of lead should be less than 1.6ng/mL;

--- Precision. measure up to 10 times the standard solution, the absorbance of the standard deviation should not exceed 0.8% of the mean absorbance; the lowest

Concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum concentration standard

The average absorbance of standard solution of 0.4%;

--- Linear curve. the curve according to concentration, divided into five sections, the difference between the absorbance of the absorbance difference between the highest and the lowest segment segment

Ratio of not less than 0.7.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 4325.1

EditionTitleRevisionStatus
GB/T 4325.1-2013Methods for chemical analysis of molybdenum - Part 1: Determination of lead content - Graphite furnace atomic absorption spectrometrycurrent editionCurrent
GB/T 4325.1-1984Methods for chemical analysis of molybdenum - Part 1: Determination of lead content - Graphite furnace atomic absorption spectrometryprevious editionSuperseded

This page sells the current edition, GB/T 4325.1-2013. Earlier editions are listed for reference only.

How to Download GB/T 4325.1-2013

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 4325.1-2013

$105.00