Valid

GB/T 42248-2022Soil and stream sediment—Determination of iodine and bromine content—Decomposition by sintering inductively coupled plasma mass spectrometry (English PDF)

土壤、水系沉积物 碘、溴含量的测定 半熔-电感耦合等离子体质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 42248-2022 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 30, 2022

Implementation date

April 1, 2023

Scope

GB/T 42248-2022 is the English-translated version of 土壤、水系沉积物 碘、溴含量的测定 半熔-电感耦合等离子体质谱法.

GB/T 42248-2022 describes a method for determining iodine and bromine in soil and stream sediment by sintering decomposition followed by inductively coupled plasma mass spectrometry.

The sample is sintered at high temperature in a muffle furnace with a mixed sodium carbonate and zinc oxide reagent, leached in hot water, freed of the large amount of sodium and other cations, and then measured on an ICP-MS using the isotopes 127I and 79Br, whose mass spectrometric counts are proportional to mass concentration within a certain concentration range.

The method detection limit is 0.11 µg/g for iodine and 0.2 µg/g for bromine, and the determination ranges are 0.37 µg/g to 100 µg/g for iodine and 0.66 µg/g to 100 µg/g for bromine. Issued on 30 December 2022, it has applied since 1 April 2023.

Found what you need?

Document preview — GB/T 42248-2022

National Standard of the People's Republic of China

ICS
73.080
Classification
D 47

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Principles

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.

1 Scope

This document describes a method for the determination of iodine and bromine in soil and water sediments by semi-melting-inductively coupled plasma mass spectrometry.

This document is applicable to the determination of iodine and bromine content in soil and water system sediments with the following determination ranges and method detection limits.

---Method detection limit, iodine is 0.11µg/g, bromine is 0.2µg/g;

---Measurement range, iodine is 0.37µg/g~100µg/g, bromine is 0.66µg/g~100µg/g.

2 Normative references

The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 6041 General rules for mass spectrometry methods

GB/T 6379.2 Accuracy of measurement methods and results (trueness and precision) - Part 2: Determination of repeatability of standard measurement methods Fundamental methods of sex and reproducibility

GB/T 6379.4 Accuracy of measurement methods and results (trueness and precision) Part 4: Determining the correctness of standard measurement methods basic method of degree

GB/T 6682 Analytical laboratory water specifications and test methods

GB/T 14505-2010 General principles and general provisions for chemical analysis methods of rocks and ores

GB/T 14506.1 Methods for Chemical Analysis of Silicate Rocks Part 1: Determination of Adsorbed Water

GB/T 33087 Specifications and test methods of high-purity water for instrumental analysis. Calibration specification for JJF1159 quadrupole inductively coupled plasma mass spectrometer

3 Terms and Definitions

This document does not have terms and definitions that need to be defined.

4 Principles

The sample is melted at high temperature in a muffle furnace by a mixed reagent of sodium carbonate and zinc oxide, and then leached in hot water.

Exchange and separate a large amount of sodium and other cations in the solution, and use an inductively coupled plasma mass spectrometer to measure the sample solution, with iodine isotopes 127I and The bromine element isotope 79Br is qualitative. Within a certain concentration range, the mass spectrometry count value of iodine and bromine elements is proportional to the mass concentration of iodine and bromine elements.

Calculate the content of iodine and bromine in the sample by measuring the mass spectrometer count value of iodine and bromine.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 42248-2022

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 42248-2022

$195.00