Scope
GB/T 42066-2022 is the English-translated version of 急性病毒性感染呼吸道样本采集.
GB/T 42066-2022 sets out how respiratory specimens are collected when an acute viral infection is suspected.
It covers the whole chain - enrolling the subject and filling in the information, the request and preparation, the collection itself, temporary storage, packaging, transport, reception and storage - and names the specimen types it deals with: throat and nasopharyngeal swabs, nasopharyngeal and respiratory tract aspirates, deep cough and induced sputum, bronchial washings and alveolar lavage fluid.
It also fixes the sampling tubes, solutions and swabs, the grounds for rejecting a sample, and the biosafety side: personal protective equipment, hand hygiene, protection of the subject, environmental disinfection and waste disposal.
It is written for disease control bodies, customs and biobanks, and only where acute viral respiratory infection has already been judged possible. Issued on 12 October 2022, it has applied since the same date.
Found what you need?
Document preview — GB/T 42066-2022
National Standard of the People's Republic of China
- ICS
- 07.080
- Classification
- C 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Acute viral infection respiratory sample collection process
- 5.1 Sample collection flow chart
- 5.2 Inclusion of sample collection objects and information filling
- 5.3 Application for Sample Collection
- 5.4 Preparation before sample collection
- 5.5 Sample Collection
- 5.6 Temporary storage of samples
- 5.7 Sample Packaging and Shipping
- 5.8 Sample reception
- 5.9 Sample storage
- 6 Biosafety
- 6.1 Personal protective equipment
- 6.2 Hand Hygiene
- 6.3 Sample object protection
- 6.4 Environmental disinfection
- 6.5 Waste disposal
- 7 Sample Collection Materials
- 7.1 Sampling tube
- 7.2 Sampling solution
- 7.3 Sampling swab
- 8 Sample Collection Information Registration Form
- 9 Sample collection tube identification
- 10 Sampling Information Report
- 11 Types and methods of sample collection
- 11.1 Types of sample collection
- 11.2 Sample collection method
- 12 Temporary storage of samples
- 13 Sample Packaging and Shipping
- 13.1 Sample packaging
- 13.2 Sample transport
- 14 Sample Receipt, Storage and Rejection
- 14.1 Sample receipt and storage
- 14.2 Sample rejection
- 14.3 Disposal of rejected samples
- Appendix A (informative) Collection process of respiratory tract samples for acute viral infection
- Appendix B (Informative) Sample Collection Information Registration Form Example
- Appendix C (Informative) Containing culture medium sampling solution formula
- Appendix D (Informative) Sputum Digestive Solution Storage Solution Formula
- Appendix E (Informative) Sample Packaging Schematic
- Reference
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.
1 Scope
This document describes methods for sample collection techniques such as collection, storage, and transportation of respiratory samples for acute viral infections.
This document is applicable to the disease control system, customs and biological sample bank, etc., and is used to guide relevant staff to carry out sample inclusion, information collection, and sample collection.
The collection, preservation and transportation of samples shall be standardized, and the quality and safety management of sample collection shall be standardized.
Note: This document is only applicable to the situation where it has been preliminarily determined that the sampling object may be acute viral respiratory infection, not applicable to non-acute viral infection respiratory Collection of road samples.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB 19489 General Requirements for Laboratory Biosafety gerousgoodsbyair)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.3 Equipment and supplies to prevent individual personnel from being harmed by biological, chemical or physical risk factors. [Source: GB 19781-2005, 3.18, modified]
3.1 Acute viral respiratory tract infection
Acute respiratory tract infection caused by viruses can be divided into upper respiratory tract infection and lower respiratory tract infection, which can be caused by a variety of respiratory tract viruses, often
Common respiratory viruses include influenza virus, coronavirus, rhinovirus, parainfluenza virus, adenovirus and respiratory syncytial virus.
3.2 Respiratory samples
Upper or lower respiratory tract samples for detection of pathogens in respiratory tract infections, including throat swabs, nasopharyngeal swabs, nasopharyngeal extracts or breath Aspiration tract extracts, deep cough sputum, induced sputum, bronchial washing fluid and alveolar lavage fluid, etc.
4 Abbreviations
The following abbreviations apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 42066-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 19489-2008 — Laboratories - General requirements for biosafety
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 42066-2022
$240.00