GB/T 41739-2022Test method for dimensional stability of metal matrix composites—Thermal-cold cycling method (English PDF)
金属基复合材料尺寸稳定性检测方法 冷热循环法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41739-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 14, 2022
Implementation date
February 1, 2023
Scope
GB/T 41739-2022 is the English-translated version of 金属基复合材料尺寸稳定性检测方法 冷热循环法.
GB/T 41739-2022 specifies how the dimensional stability of a metal matrix composite is detected in real time by thermal-cold cycling. A single-push-rod or double-push-rod thermal dilatometer with a quartz differential component measures the change in sample length at 20 °C before the first cycle and after each of the fifteen thermal-cold cycles.
The document applies to aluminium and magnesium matrix composites cycled between 20 °C and 150 °C, and to iron matrix composites cycled between 20 °C and 490 °C. It covers the test principle, the samples, the test devices and procedure, the test results and the test report, and it requires the apparatus to be calibrated every six months with high-purity fused silica standard samples.
Clause 2 cites GB/T 4339 and JC/T 2250. It was issued on 14 October 2022 and has applied since 1 February 2023.
Found what you need?
Document preview — GB/T 41739-2022
National Standard of the People's Republic of China
- ICS
- 77.040.99
- Classification
- Y 80
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Test principle4
- 4 Samples4
- 5 Test devices and test procedure5
- 6 Test results7
- 7 Test report8
1 Scope
This document specifies the test principle, samples, test devices and test procedure, test results, and test report for real-time detection of the dimensional stability of metal matrix composites using the thermal-cold cycle.
This document applies to the determination for dimensional stability of aluminum matrix composites (thermal-cold cycling temperature range: 20 °C ~ 150 °C), magnesium matrix composites (thermal-cold cycling temperature range: 20 °C ~ 150 °C) and iron matrix composites (thermal-cold cycling temperature range: 20 °C ~ 490 °C).
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the version corresponding to that date is applicable to this document; for undated references, the latest version (including all amendments) is applicable to this document.
GB/T 4339, Test methods for thermal expansion characteristic parameters of metallic materials
JC/T 2250, Fused silica
3 Test principle
This document uses a single-push-rod or double-push-rod thermal dilatometer, with the help of a quartz differential component of the same stable material, to measure the length variation of the metal matrix composite at 20 °C before the first cycle and after each thermal-cold cycle (among 15 thermal-cold cycles in total). The push rod transmits the variation in sample length to the sensor, and the shape and size of the push rod shall ensure that the load is applied to the sample.
4 Samples
4.1 Sample cutting and processing
Samples shall be cut mechanically at room temperature (15 °C ~ 25 °C).
5 Test devices and test procedure
The requirements for the measuring device for length variation are as follows:
a) The measurement range of length variation shall be 0 mm ~ 2.5 mm, and the resolution shall not be lower than 10-6 mm;
b) Use a constant temperature water bath to keep the temperature of the measuring device for length variation stable; the temperature variation shall not be greater than ±0.5 °C.
5.1.3 Heating and cooling device
The requirements for the heating and cooling device are as follows:
a) No matter which heating or cooling method is used, the temperature shall be controlled;
b) Either the heating device or the cooling device shall have a uniform temperature zone greater than the sample length, and the maximum temperature difference in the uniform temperature zone shall not be greater than 2 °C;
c) The heating and cooling rate of the sample shall be 5 °C/min.
5.1.4 Temperature measuring device
The temperature measurement accuracy of the thermocouple is ±0.2 °C.
5.1.5 Control system
The control system shall be able to set different temperature programs during the test and be able to perform automatic control. The control system shall be able to detect the shielding gas flow of the test system in real time. When the requirements of the test system cannot be met, the control system shall be able to automatically cut off the power.
5.1.6 Data collecting and processing system
The data collecting and processing system shall be able to continuously and automatically collect the data of the test temperature and length variation in the whole process, and be able to perform data analysis, calculation, drawing and correction.
5.2 Device calibration
The device has to be calibrated and then re-calibrated every six months.
High-purity fused silica standard samples are used for device calibration. The test conditions and procedures used for device calibration, such as temperature history, ambient atmosphere, shall be the same as those used for testing samples. The obtained length variation shall be used as the baseline value, which is used to correct the experimental results during data analysis. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 41739-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4339-2008 — Test methods for thermal expansion characteristic parameters of metallic materials
GB/T 43390-2023 — Market, opinion and social research—Guidelines for mobile research
GB/T 43391-2023 — Market, opinion and social research—Guidelines for preparation of the research reports
Secure payment via Stripe
Payments accepted
GB/T 41739-2022
$150.00