Valid

GB/T 41191-2021Flare for biogas engineering (English PDF)

沼气工程火焰燃烧器

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 41191-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 31, 2021

Implementation date

July 1, 2022

Scope

GB/T 41191-2021 is the English-translated version of 沼气工程火焰燃烧器.

GB/T 41191-2021 covers the flares that burn off the biogas a biogas plant cannot otherwise use. It sets the classification and model designation of these flame burners, their technical requirements, test methods, inspection rules, and packaging, transport and storage, and it adds rules for installing them.

An informative annex gives the fire separation distances between biogas flares or vents and the main surrounding facilities. The definitions cover the ignition device, the flame monitor with its UV sensor and flame transmitter, the turn-down ratio and the burning residence time of the biogas in the combustion chamber.

It applies to the production and installation of flares in biogas projects. It was issued on 31 December 2021 and has applied since 1 July 2022.

Found what you need?

Document preview — GB/T 41191-2021

National Standard of the People's Republic of China

ICS
27.060.20
Classification
P 47

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 Classification and model preparation
  • 5 Technical requirements
  • 6 Test method
  • 7 Inspection Rules
  • 8 Packaging, transport and storage
  • 9 Install
  • Appendix A (informative) Fire separation distance between biogas flares or vents and surrounding main facilities

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1. Structure and Drafting Rules of Standardization Documents" drafted.

1 Scope

This document specifies the classification, technical requirements, test methods, inspection rules, packaging, transportation and storage of flame burners for biogas projects, and installation etc.

This document applies to the production and installation of flame burners for biogas projects.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.

GB/T 1226-2017 General pressure gauge

GB 3096-2008 Sound Environment Quality Standard

GB/T 13384-2008 General technical conditions for packaging of mechanical and electrical products

GB/T 18604-2014 Measuring natural gas flow with gas ultrasonic flowmeter

GB/T 30429-2013 Industrial Thermocouple

JB/T 13390-2018 Infrared scanning thermometer

SH 3009-2013 Design specification for petrochemical combustible gas emission system

3 Terms and Definitions

The following terms and definitions apply to this document.

3.1 Biogas Torch

It is a device used to burn the biogas that cannot be used normally in the biogas project.

3.2 Ignition device

It is a device composed of ignition transformer, ignition electrode, permanent light, gas pipeline, valve, flame arrester, gas source, connecting cable and other components.

3.3 Flame monitor

A device used to monitor the combustion of a flame.

Note: Includes UV sensor and flame transmitter.

3.4 Turn-down ratio

Under normal combustion conditions, the ratio of the maximum flow rate and the minimum flow rate of biogas that can be normally burned by the biogas flare.

3.5 Burning residence time

The time that the biogas stays in the combustion chamber.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 41191-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 41191-2021

$165.00