GB/T 39927-2021Determination of prohibited substances veratrine in cosmetics—High performance liquid chromatography (English PDF)
化妆品中禁用物质藜芦碱的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 39927-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 9, 2021
Implementation date
October 1, 2021
Scope
GB/T 39927-2021 is the English-translated version of 化妆品中禁用物质藜芦碱的测定 高效液相色谱法.
GB/T 39927-2021 sets out a high performance liquid chromatography method for detecting veratridine, the main component of veratrine, a substance prohibited in cosmetics.
It covers the principle, the reagents and materials, the apparatus, sample processing by extraction with methanol and dilute hydrochloric acid, the chromatographic conditions on a C18 column with diode array or ultraviolet detection at 261 nm, the standard working curve, blank and parallel tests and the calculation of results.
Positive samples can be confirmed by liquid chromatography-tandem mass spectrometry. The method applies to facial masks, creams, milks and water-type cosmetics, with a detection limit of 15 mg/kg and a limit of quantification of 50 mg/kg, and it states the recovery rate, the precision and the allowed difference between two results. It was issued on 9 March 2021 and has applied since 1 October 2021.
Found what you need?
Document preview — GB/T 39927-2021
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents and materials
- 5 Apparatus and equipment
- 6 Test procedure
- 7 Result calculation
- 8 Recovery rate and precision
- 9 Tolerance
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
Veratrine is a prohibited substance stipulated in my country's "Cosmetics Safety Technical Specification (2015 Edition)". The tested substance of this standard is Veratridine. The main component of ruline.
Prohibited substances refer to substances that cannot be added to cosmetics as raw materials or components in cosmetics production. "Cosmetics Safety Technical Specification (2015 Edition)'' stipulates. If it is technically unavoidable that prohibited substances are brought into cosmetics as impurities, the limited amount of national regulations shall comply with its regulations.
If the limit is not specified, a safety risk assessment should be carried out to ensure that no harm to human health is allowed under normal, reasonable and foreseeable use conditions. Health hazards.
At present, my country has not stipulated the limit value of this substance. The formulation of this standard only provides detection methods for the determination of this substance in cosmetics.
1 Scope
This standard specifies the principles, reagents, materials, and instruments of the high performance liquid chromatography method for the determination of veratridine, the main component of veratridine in cosmetics.
And equipment, test procedures, result calculations, recovery rate and precision, tolerances, etc.
This standard applies to the determination of veratridine in facial masks, creams, milk, and water cosmetics.
The detection limit of this standard method is 15mg/kg, and the limit of quantification is 50mg/kg.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
3 Principle
After the sample was extracted, it was separated by high performance liquid chromatography, qualitatively based on retention time, quantified by peak area, and quantified by external standard method. If necessary, use liquid Confirmed by gas chromatography-mass spectrometry.
4 Reagents and materials
Unless otherwise stated, all reagents used are of analytical grade.
4.1 Water, GB/T 6682, level one.
4.2 Methanol. chromatographically pure.
4.3 Hydrochloric acid. pure superior grade.
4.4 0.1mol/L hydrochloric acid solution. Measure 8.3mL of hydrochloric acid (4.3) and add water to 1L.
4.5 Ammonium acetate.
4.6 Extraction solution. Take 500mL of 0.1mol/L hydrochloric acid solution (4.4), add methanol (4.2) and mix well and dilute to 1L. Membrane filtration.
4.7 Veratridine standard product. the purity is not less than 99.0%, the English name, CAS number, molecular formula, relative molecular mass and structural formula of veratridine See Table A.1 in Appendix A.
4.8 Veratridine standard working solution. accurately weigh 10mg of veratridine standard (accurate to 0.0001g) into a 10.0mL volumetric flask, Dissolve and fix the volume with the extract (4.6) to prepare a standard stock solution of Veratridine with a mass concentration of 1000 mg/L (store 1 in the refrigerator at -20°C) month). Use the extract (4.6) to dilute the veratridine standard stock solution step by step to form a mass concentration of 2.0mg/L, 5.0mg/L, 10mg/L, The standard working solutions of 50mg/L and 100mg/L are ready for use.
4.9 0.1mol/L ammonium acetate. 7.71g ammonium acetate (4.5) is dissolved in 1.0L water.
5 Apparatus and equipment
5.1 High performance liquid chromatograph equipped with a diode array (DAD) detector or an ultraviolet detector.
5.2 Liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) instrument. equipped with an electrospray ion source (ESI).
5.3 Analytical balance, with a sense of 0.0001g.
5.4 Ultrasonic oscillator. working frequency 53kHz.
5.5 Centrifuge. speed >=8000r/min.
5.6 Membrane. The pore size is 0.45µm, and the material is polytetrafluoroethylene.
5.7 Colorimetric tube with stopper. 10mL.
5.8 Vortex oscillator.
6 Test procedure
6.1 Sample processing
For facial mask (take mask liquid), cream, milk, and water cosmetics, weigh about 1g of sample (accurate to 0.0001g) in 10mL with a plug ratio In the color tube, dilute to the mark with the extraction solution (4.6), vortex for 30s, ultrasonically extract for 10min, centrifuge at 8000r/min for 10min, take it The clear solution was filtered through a 0.45µm filter membrane, and the filtrate was used as the sample solution to be tested for determination under chromatographic conditions.
6.2 Measurement conditions
The reference conditions for HPLC determination are as follows.
a) Chromatographic column. C18 reversed phase column, 250mm×4.6mm (particle size 5µm), or other equivalent performance;
b) Mobile phase. methanol (4.2) 0.1mol/L ammonium acetate (4.9) = 60 40 (volume ratio);
c) Flow rate. 1.0mL/min;
d) Column temperature. 40°C;
e) Detection wavelength. 261nm;
f) Injection volume. 10µL.
6.3 Drawing standard working curve
According to 6.2 chromatographic conditions, draw 10 µL of veratridine standard working solution (4.8) and inject into the high performance liquid chromatograph.
The peak area is the ordinate, the corresponding solution concentration is the abscissa, and the standard working curve is drawn.
For the high performance liquid phase (HPLC) chromatogram of the veratridine standard, see Figure B.1 in Appendix B.
6.4 Sample measurement
According to the chromatographic conditions in 6.2, take the filtrate in step 6.1 and inject the sample to obtain the peak area of the sample solution.
The spectrogram is qualitative, and the DAD spectrogram of veratridine standard is shown in Figure B.2.Check the content of veratridine in the sample solution from the standard curve.
The response value of veratridine in the sample solution should be within the linear range of the standard curve, and it should be measured after dilution if it exceeds the linear range. When necessary, Yang Sexual samples need to be confirmed by liquid chromatography-mass spectrometry (see Appendix C).
6.5 Blank test
Except that the sample is not weighed, follow steps 6.1 to 6.4.
6.6 Parallel test
Follow steps 6.1 to 6.4 to perform parallel test determinations on the same sample.
7 Result calculation
The content of veratridine in the sample is calculated according to formula (1).
Where.
X --- the content of veratridine in the sample, in milligrams per kilogram (mg/kg);
rho ---Find the mass concentration of veratridine from the standard curve, in milligrams per liter (mg/L);
V --- the total volume of the diluted sample, in milliliters (mL);
m ---The mass of the sample, in grams (g).
The blank value should be deducted from the calculation result, and three significant figures should be retained.
8 Recovery rate and precision
When the additive concentration is within the range of 50.0mg/kg~500.0mg/kg, the recovery rate is between 83.5%~112.2%, the relative standard deviation Less than 5%.
9 Tolerance
The absolute difference between two independent determination results obtained under repeatability conditions should not exceed 10% of the arithmetic mean.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 39927-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 39927-2021
$150.00