Valid

GB/T 39853.1-2021Power quality measurement in power supply systems - Part 1: Power quality instruments(PQI) (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (51 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39853.1-2021 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

March 9, 2021

Implementation date

October 1, 2021

Scope

GB/T 39853.1-2021 (Power quality measurement in power supply systems - Part 1: Power quality instruments(PQI)) is available as an English-translated PDF.

GB/T 39853.1-2021 is the Chinese standard "Power quality measurement in power supply systems - Part 1: Power quality instruments(PQI)".

Its scope clause reads: This part of GB/T 39853 specifies the measurement method (Class A or Class S) defined by IEC 61000-4-30.2015, with The performance requirements of products and instruments that measure, record and monitor the power quality parameters of the power supply system.

These requirements apply to single-phase, two-phase (divided Phase) and three-phase AC 50Hz or 60Hz power supply system.

Such instruments are used for. ---In power generation, transmission and distribution systems, such as power plants, substations or distributed power generation systems; --- The connection point between the facility and the power grid, for example to check whether the power grid operator and user follow the connection agreement.

Note. These instruments can also be used in other applications, such as in commercial and/or industrial facilities, especially where comparable measurements are made (such as data centers or petrochemicals). plant).

These instruments are either fixed or portable, and are used indoors and/or outdoors. Equipment such as digital fault recorders, electric energy/power instruments, protective relays or circuit breakers can be equipped with IEC 61000-4-30.2015 Defined Class A or Class S power quality functions.

If such equipment is required to comply with this part, then in addition to the relevant product standards, this part is fully applicable. Used for these devices.

This part does not replace relevant product standards. This section does not involve user interfaces or topics that are not related to the measurement performance of the device.

This section does not cover the post-processing and interpretation of data, such as special software.

Found what you need?

Document preview — GB/T 39853.1-2021

National Standard of the People's Republic of China

Classification
N 22

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions, symbols and abbreviations
  • 3.1 General definition
  • 3.2 Environmental related terms and definitions
  • 3.3 Uncertainty related definitions
  • 3.4 Symbol
  • 4 Environmental conditions
  • 4.1 Overview
  • 4.2 Environment FI1, FI2, FI1-H, FI2-H, FO and FO-H
  • 4.3 Environmental PI, PI-H, PO and PO-H
  • 4.4 The relationship between ambient air temperature and relative humidity
  • 5 Rating
  • 5.1 Rated input excitation voltage
  • 5.2 Rated frequency
  • 6 Design and structure
  • 6.1 Overview
  • 6.2 Basic architecture
  • 6.3 Functions of PQI-A and PQI-S
  • 6.4 Additional requirements supplemented to IEC 61000-4-30
  • 6.5 Safety requirements
  • 6.6 EMC requirements
  • 6.7 Climatic requirements for PQI
  • 6.8 Mechanical structure requirements
  • 6.9 Enclosure protection class
  • 6.10 Startup requirements
  • 7 Signs and operating instructions
  • 7.1 Overview
  • 7.2 Sign
  • 7.3 Operating instructions
  • 8 Function, environment and safety type test
  • 8.1 Overview
  • 8.2 Type test reference conditions
  • 8.3 Safety test
  • 8.4 Electromagnetic compatibility test
  • 8.5 Climate test
  • 8.6 Mechanical test
  • 8.7 Function and uncertainty test
  • 9 Routine test
  • 9.1 Overview
  • 9.2 Protective earthing test
  • 9.3 Dielectric strength test
  • 9.4 Inherent uncertainty test
  • 10 Certification and declaration
  • 11 Recalibration and reverification
  • Appendix A (informative appendix) EMCG environment and EMCH environment information
  • References

1 Scope

This part of GB/T 39853 specifies the measurement method (Class A or Class S) defined by IEC 61000-4-30.2015, with

The performance requirements of products and instruments that measure, record and monitor the power quality parameters of the power supply system. These requirements apply to single-phase, two-phase (divided

Phase) and three-phase AC 50Hz or 60Hz power supply system.

Such instruments are used for.

---In power generation, transmission and distribution systems, such as power plants, substations or distributed power generation systems;

--- The connection point between the facility and the power grid, for example to check whether the power grid operator and user follow the connection agreement.

Note. These instruments can also be used in other applications, such as in commercial and/or industrial facilities, especially where comparable measurements are made (such as data centers or petrochemicals).

plant).

These instruments are either fixed or portable, and are used indoors and/or outdoors.

Equipment such as digital fault recorders, electric energy/power instruments, protective relays or circuit breakers can be equipped with IEC 61000-4-30.2015

Defined Class A or Class S power quality functions. If such equipment is required to comply with this part, then in addition to the relevant product standards, this part is fully applicable.

Used for these devices. This part does not replace relevant product standards.

This section does not involve user interfaces or topics that are not related to the measurement performance of the device.

This section does not cover the post-processing and interpretation of data, such as special software.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 16935.1-2008 Insulation coordination of equipment in low-voltage systems Part 1.Principles, requirements and tests (IEC 60664-1.

2007, IDT)

IEC 60068-1 Environmental Testing Part 1.Overview and Guidelines (Environmental testing-Part 1.General and guidance)

IEC 60068-2-1 Environmental testing Part 2-1.Test method Test A. Low temperature (Environmental testing-Part 2-1.

Tests-TestsA.Cold)

IEC 60068-2-2 Environmental testing Part 2-2.Test method Test B. Dry heat (Environmental testing-Part 2-2.

Tests-TestsB.Dryheat)

IEC 60068-2-6 Environmental Test Part 2-6.Test Method Test Fc. Vibration (Sine) (Environmental testing-Part 2-6.Tests-TestFc.Vibration(sinusoidal)]

IEC 60068-2-14 Environmental testing Part 2-14.Test method Test N. Temperature change (Environmental testing-

Part 2-14.Tests-TestN.Changeoftemperature)

IEC 60068-2-27 Environmental Testing Part 2-27.Test Test Ea and Guideline. Impact (Environmentaltesting-

Part 2-27.Tests-TestEaandguidance.Shock)

IEC 60068-2-31 Environmental Test Part 2-31.Test Test Ec. Shock caused by rough operation (mainly used for equipment type

Sample) (Environmentaltesting-Part 2-31.Tests-TestEc.Roughhandlingshocks,primarily for

GB/T 15284 | GB/T 17215.321 | GB/T 34067.2 | GB/T 17215.241 | GB/T 13850 | GB/T 39853.2 | […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 51 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 39853.1-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
51 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39853.1-2021