GB/T 39226-2020Requirements on the integrated test for high power converter system of magnetic confinement fusion (English PDF)
磁约束聚变大电流变流系统集成测试要求
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 39226-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB/T 39226-2020 is the English-translated version of 磁约束聚变大电流变流系统集成测试要求.
GB/T 39226-2020 fixes the test items, the test conditions, the test methods and processes, and the qualification criteria for the integration of magnetic confinement fusion high current converter systems.
Clause 1 states that it applies to the integration test of such systems when they use thyristors greater than 10 kA.
The body is short: after Scope, Normative references and Terms and definitions come Requirements for integration testing and Test method and process, with an informative Appendix A holding the structure diagram of a 12-pulse, four-quadrant operation converter unit.
Clause 2 cites GB/T 2900.33-2004, GB/T 3859.1-2013, GB/T 3859.3-2013, GB/T 12325, GB/T 12326, GB/T 14549 and GB/T 15543.
Clause 3 repeats some of the terms of GB/T 2900.33-2004 for ease of use and defines magnetic confinement fusion as the nuclear fusion reaction produced by using a strong magnetic field to confine high-temperature, high-density plasma for long enough, AC/DC converter as a power electronic converter used for rectification or inversion or both, semiconductor converter as one using semiconductor valve devices, and integration testing as the performance test of a complete converter system made up of semiconductor converter, rectifier transformer, DC switch and controller.
The page shows the front matter and these first three clauses only, and the draft stops before the requirements clause.
The standard was proposed and is managed by the National Nuclear Energy Standardization Technical Committee (SAC/TC58); the page lists the Institute of Plasma Physics of the Chinese Academy of Sciences, Rongke Hengyang Rectifier Technology Co., Ltd. and Huazhong University of Science and Technology as its drafting organizations, records it under ICS 27.120 and the Chinese classification F60, and traces it to National Standard Announcement No. 26 of 2020. It was issued on 2020-11-19 and has applied since 2021-06-01.
Found what you need?
Document preview — GB/T 39226-2020
National Standard of the People's Republic of China
- ICS
- 27.120
- Classification
- F 60
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Requirements for integration testing
- 5 Test method and process
- Appendix A (informative appendix) Structure diagram of 12-pulse, four-quadrant operation converter unit
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the test items, test conditions, test methods/processes and qualification judgment guidelines for the integration of magnetic confinement fusion high-current converter systems.
This standard is applicable to the integration test of the magnetic confinement fusion high current converter system using thyristors greater than 10kA.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.
For undated references, the latest version (including all amendments) applies to this document.
GB/T 2900.33-2004 Electrical terminology power electronic technology
GB/T 3859.1-2013 General requirements for semiconductor converters and power grid commutated converters Part 1-1.Basic requirements specifications
GB/T 3859.3-2013 General requirements for semiconductor converters and power grid commutated converters Part 1-3.Transformers and reactors
GB/T 12325 Power quality supply voltage deviation
GB/T 12326 Power quality voltage fluctuation and flicker
GB/T 14549 Power quality public grid harmonics
GB/T 15543 Power quality three-phase voltage unbalance
3 Terms and definitions
The following terms and definitions defined in GB/T 2900.33-2004 apply to this document. For ease of use, the following is repeated Some terms and definitions in GB/T 2900.33-2004.
3.1 Magnetic confinement fusion
The nuclear fusion reaction produced by using a strong magnetic field to confine high-temperature and high-density plasma for a long enough time.
3.2 AC/DC converter
Power electronic converters used for rectification or inversion, or both rectification and inversion.
3.3 Semiconductor converter
Power electronic converters using semiconductor valve devices. [GB/T 2900.33-2004, definition 551-12-42]
3.4 Integration Testing
Performance test of a complete converter system consisting of semiconductor converter, rectifier transformer, DC switch and controller.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.33-2004Electrotechnical terminology -- Power electronics
- GB/T 3859.1-2013Semiconductor converters -- General requirements and line commutated Converters -- Part 1-1: Specification of basic requirements
- GB/T 3859.3-2013Semiconductor converters -- General requirements and line commutated converters -- Part 1-3: Transformers and reactors
- GB/T 12325Power quality - Deviation of supply voltage
- GB/T 12326Power quality - Voltage fluctuation and flicker
- GB/T 14549Quality of electric energy supply--Harmonics inpublic supply network
Similar standards
How to Download GB/T 39226-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12325-2008 — Power quality - Deviation of supply voltage
GB/T 12326-2008 — Power quality - Voltage fluctuation and flicker
GB/T 14549-1993 — Quality of electric energy supply--Harmonics inpublic supply network
Secure payment via Stripe
Payments accepted
GB/T 39226-2020