GB/T 38693-2020Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Thermoelectric flame supervision controls (English PDF)
燃气燃烧器和燃烧器具用安全和控制装置 特殊要求 热电式熄火保护装置
This is a limited preview
Buy now to download the full PDF (51 pages)
Need quotation for your management?
Get a formal quotation for GB/T 38693-2020 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
March 31, 2020
Implementation date
February 1, 2021
Scope
GB/T 38693-2020 is the English-translated version of 燃气燃烧器和燃烧器具用安全和控制装置 特殊要求 热电式熄火保护装置.
GB/T 38693-2020 is the Chinese standard "Safety and control devices for gas burners and gas-burning appliances - Particular requirements - Thermoelectric flame supervision controls".
Its scope clause reads: This standard specifies thermoelectric flameout protection devices for burners and burning appliances that use urban gas specified in GB/T 13611 (to (Hereinafter referred to as "flame protection device") classification and grouping, structure and materials, requirements, test methods, inspection rules, marking, installation and operating instructions Books, packaging, transportation and storage.
This standard applies to gas burners and heating appliances with a maximum working pressure not greater than 500kPa and a nominal size not greater than DN50. Electric flameout protection device. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 38693-2020
National Standard of the People's Republic of China
- ICS
- 91.140
- Classification
- P 45
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Classification and grouping
- 4.1 Flameout protection device classification
- 4.2 Flameout protection device group
- 5 Structure and materials
- 5.1 General requirements
- 5.2 Structure
- 5.3 Material
- 5.4 Gas connection
- 6 Requirements
- 6.1 General requirements
- 6.2 Component requirements
- 6.3 Performance requirements
- 7 Test method
- 7.1 Test conditions
- 7.2 Component test
- 7.3 Performance test
- 8 Inspection rules
- 8.1 Factory inspection
- 8.2 Type inspection
- 9 Signs, installation and operating instructions
- 9.1 Sign
- 9.2 Installation and operating instructions
- 9.3 Warning notice
- 10 Packaging, transportation and storage
- Appendix A (informative appendix) Structural changes of this standard compared with ISO 23551-6.2014
- Appendix B (informative appendix) Technical differences between this standard and ISO 23551-6.2014 and their reasons
- Appendix C (informative appendix) This standard supports GB 16914-2012 basic requirements of clause correspondence table
- Appendix D (informative appendix) schematic diagram of flameout protection device form and composition
- Appendix E (informative appendix) Thermocouple installation for flame sensing
- Appendix F (informative appendix) Test device for separate inspection of solenoid valve
1 Scope
This standard specifies thermoelectric flameout protection devices for burners and burning appliances that use urban gas specified in GB/T 13611 (to (Hereinafter referred to as "flame protection device") classification and grouping, structure and materials, requirements, test methods, inspection rules, marking, installation and operating instructions
Books, packaging, transportation and storage.
This standard applies to gas burners and heating appliances with a maximum working pressure not greater than 500kPa and a nominal size not greater than DN50.
Electric flameout protection device.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 2828.1 Sampling inspection procedure by attributes Part 1.Batch inspection sampling plan retrieved by acceptance quality limit (AQL) (GB/T 2828.1-2012, ISO 2859-1.1999, IDT)
GB/T 13611 Classification and basic characteristics of urban gas
GB/T 30597-2014 General requirements for safety and control devices for gas burners and burning appliances (ISO 23550.2011,
MOD)
3 Terms and definitions
The following terms and definitions defined in GB/T 30597 apply to this document. For ease of use, the following is repeated
Certain terms and definitions in GB/T 30597.
3.1 Thermoelectric flameout protection device
The valve body, solenoid valve, and thermocouple can respond to the thermoelectric potential generated by the thermocouple, and make it lead to the main burner or the main burner and ignition
The gas passage of the burner is opened, and after the monitored flame is extinguished, the device can automatically cut off the gas passage.
Note. See Appendix D for the form and composition diagram of the flameout protection device.
3.2 Solenoid valve
A type of thermoelectric potential generated by a thermocouple installed in the valve body to maintain the open state of the gas path, and can be used after the monitored flame is extinguished
The part that closes the gas passage.
3.3 Thermocouple
The flame sensing element responds to the temperature of the monitored flame to generate thermoelectric potential.
3.4 Ignition interlock
As long as the passage to the main burner is opened, the component that can prevent the igniter from operating.
GB/T 39488 | GB/T 39485 | GB/T 39434 | GB/T 45384 | GB 45833 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 51 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2828.1Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 2828.1-2012Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
- GB/T 13611Classification and basic characteristics of urban gas
- GB/T 30597-2014General requirements of safety and control devices for gas burners and gas-burning appliances
ISO 2859 · ISO 23550.2011
How to Download GB/T 38693-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13611-1992 — Classification of town gas
GB/T 13611-2006 — Classification and essential property of city gas
GB/T 13611-2018 — Classification and basic characteristics of city gas
Secure payment via Stripe
Payments accepted
GB/T 38693-2020
$415.00