GB/T 38602-2020 is the English-translated version of 湿式催化氧化有机废水催化剂活性试验方法.
GB/T 38602-2020 is the Chinese standard "Test method of catalytic activity for catalytic wet oxidation of organic wastewater". Its scope clause reads: This standard specifies the catalyst activity test method for wet catalytic oxidation of organic wastewater.
This standard applies to TiO2, CeO2, ZrO2, TiO2-ZrO2, C, gamma-Al2O3 as the carrier, and Ru, Pd, Pt, Mn, Cu, Fe, Ce One or more elements are the main active components, which are used as supported catalysts for wet catalytic oxidation of benzene ring-containing organic wastewater.
Its clauses include principle; reagents or materials; test device; samples; test procedure; test data processing.
Found what you need?
Document preview — GB/T 38602-2020
National Standard of the People's Republic of China
- ICS
- 71.100.99
- Classification
- G 74
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents or materials
- 5 Test device
- 6 samples
- 7 Test procedure
- 8 Test data processing
1 Scope
This standard specifies the catalyst activity test method for wet catalytic oxidation of organic wastewater.
This standard applies to TiO2, CeO2, ZrO2, TiO2-ZrO2, C, gamma-Al2O3 as the carrier, and Ru, Pd, Pt, Mn, Cu, Fe, Ce
One or more elements are the main active components, which are used as supported catalysts for wet catalytic oxidation of benzene ring-containing organic wastewater.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 6003.1-2012 Technical requirements and inspection of test sieve Part 1.Metal wire woven mesh test sieve
GB/T 6679 General Rules for Sampling of Solid Chemical Products
GB/T 6682 Analytical laboratory water specifications and test methods
GB/T 32208 Chemical Oxygen Demand (COD) Tester
3 Principle
Phenol in wastewater is oxidized by oxygen to form carbon dioxide and water under the action of certain temperature, pressure and catalyst. The chemical reaction method is
The program is as follows.
C6H5OH 7O2=6CO2 3H2O
By measuring the chemical oxygen demand (COD) in the phenol wastewater before and after the reaction, the removal of the chemical oxygen demand (COD) in the phenol wastewater is calculated
Rate to characterize the activity of the catalyst.
4 Reagents or materials
4.1 Phenol
The purity is greater than 99.0%.
4.2 Deionized water
secondary water specified in GB/T 6682.
4.3 Oxygen
The purity is greater than 99.5%.
4.4 Nitrogen
purity greater than 99.5%.
5 Test device
5.1 Device
The schematic diagram of the catalyst activity test device for wet catalytic oxidation of organic wastewater is shown in Figure 1.
5.3 Check
Under normal circumstances, the parallelism and reproducibility of the test device are measured at least once a year with reference samples or reserved samples.
The provisions of Chapter 7 and Chapter 8.
6 samples
6.1 Laboratory samples
Obtained according to GB/T 6679.
6.2 Sample
Take an appropriate amount of laboratory samples and place them in an agate mortar and grind them, so that all the samples pass through a 75µm test sieve (according to GB/T 6003.1-
2012 R40/3 series), put the ground sample into a weighing bottle, dry it at 110°C±5°C for 5h, take it out and place it in a desiccator, cool
Bring to room temperature and set aside.
6.3 Sample
Weigh 1g catalyst sample, accurate to 0.001g, and set aside.
7 Test procedure
Warning---The test materials and reagents involved in this standard have toxic, flammable, and explosive hazards to human health and safety, and must be strictly
To prevent the test device from leaking, open flames are strictly prohibited on the site, and necessary fire extinguishing equipment and exhaust equipment should be equipped with preventive facilities; the autoclave is strictly prohibited
The disassembly operation is carried out under pressure; this standard does not reveal all possible safety issues, the user should strictly follow the relevant regulations and use it correctly, and is responsible
Take appropriate safety and health measures.
7.1 Raw material preparation
Weigh 5g of phenol, accurate to 0.1g, and place it in a 1000mL volumetric flask. Place the volumetric flask in a 75°C water bath and use deionized water
Make the volume to 1000mL.
7.2 Filling the reactor
Add.200 mL of raw materials and catalyst sample (6.3) to a 500 mL autoclave in sequence, close the cover, and tighten the nuts evenly
After that, connect it to the test device.
7.3 Leak test
Open the nitrogen valve, introduce nitrogen to the test device, increase the pressure of the test device to 2.0MPa, and close the inlet and outlet valves of the test device. As in
If the pressure drop within 30min is less than 0.05MPa, the test device is considered to be sealed. Open the outlet valve of the test device to reduce the pressure of the test device to normal
Press and insert the temperature measuring thermocouple into the thermowell.
7.4 Gas replacement and activity measurement
Replace the test device with nitrogen three times. After the exhaust pressure is reduced to normal pressure, change to oxygen, replace three times, and then exhaust and reduce the pressure to normal pressure.
The kettle should be heated. When the reaction kettle is heated to 180°C, oxygen is introduced, and the pressure of the test device is increased to 2.0MPa within 1 min, and controlled and maintained
The pressure of the reactor is 2.0MPa, the temperature is 180°C±2°C, and the stirring speed is 1200r/min. After 1h, the test was ended.
7.5 Parking
Turn off the oxygen, turn on the cooling water, and release the pressure after the reactor has cooled to below 60°C. After replacing the test device with nitrogen three times, sample and divide
After analysis, clean the reactor body with deionized water.
7.6 Determination of Chemical Oxygen Demand (COD)
Take the product collected in 7.5 as the test sample. Draw 10.00mL of the tested sample, place it in a 100mL volumetric flask, and dilute to
After 100mL, according to GB/T 32208, determine the chemical oxygen demand (COD) in the product (in terms of mass concentration). Follow the above steps at the same time,
Determine the chemical oxygen demand (COD) in raw materials.
8 Test data processing
The catalyst activity is calculated based on the removal rate E of chemical oxygen demand (COD), calculated according to formula (1).
E=rho1
-rho2
rho1
×100% (1)
Where.
rho1---The chemical oxygen demand (COD) in the raw material, in milligrams per liter (mg/L);
rho2---The chemical oxygen demand (COD) in the product, in milligrams per liter (mg/L).
Take the arithmetic average of three consecutive determination results as the determination result, and the range of the three determination results should not exceed 3%.
0202-
T/ […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 38602-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 38602-2020
$90.00