GB/T 3836.23-2017Explosive atmospheres - Part 23: Group I, category EPL Ma equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust (English PDF)
爆炸性环境 第23部分:用于瓦斯和/或煤尘环境的I类EPL Ma级设备
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 3836.23-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 31, 2017
Implementation date
February 1, 2018
Scope
GB/T 3836.23-2017 is the English-translated version of 爆炸性环境 第23部分:用于瓦斯和/或煤尘环境的I类EPL Ma级设备.
GB/T 3836.23-2017 is the Chinese standard "Explosive atmospheres - Part 23: Group I, category EPL Ma equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust".
Its scope clause reads: "Explosive environment" This section provides for the use of underground coal mines, as well as coal mine surface gas and/or coal dust environment type I EPLMa-class equipment design, structure, testing and marking requirements.
This section applies to the environmental conditions. Atmospheric pressure 80kPa ~ 110kPa, ambient temperature -20 °C ~ 60 °C, the standard oxygen in the air Content (volume ratio) .21%.
This section applies to coal mines, and coal mine surface gas and/or coal dust environment of all Class I EPLMa equipment Design, construction, testing and marking of gas and non-electrical equipment.
This section also applies if the transmission cables, pipes and optical fibers form part of a device that is intended for use in hazardous gas and/or dust atmospheres Some cables, pipes and fibers.
This section does not apply to mining cap lamp (GB 7957 otherwise provided). Note 1.
Since the energy required to ignite a dust cloud formed from pulverized coal and air is 600 times the energy required to ignite a gas/air mixture, this section assumes If the structure of intrinsically safe "ia" circuits is safe in explosive gas/air environments, then the circuit will operate in a pulverized coal/air explosive atmosphere Kind of safe.
Note 2. This section also gives guidance when designing equipment for use in explosive atmospheres other than those specified in 1.1 above. For this situation In the meantime, additional tests are recommended to enable manufacturers to specify the conditions under which these devices apply to these exceptions.
Note 3. When explosive gas atmospheres occur in coal mines or on the ground, the risk of ignition must be limited to a minimum. In hazardous gas and/or coal dust environments, In addition to Class I Ma Class equipment that workers must operate continuously, management may require the prohibition of certain Class Ma equipment. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 3836.23-2017
National Standard of the People's Republic of China
- ICS
- 29.260.20
- Classification
- K 35
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 EPLMa-class devices protected with a single explosion-proof version
- 6 EPLMa class equipment protected with two separate EPLMb class explosion protection types
- 8 Requirements for EPLMa intrinsically safe electrical systems
- 9 type test
- 10 logo requirements
- 11 manual
1 Scope
1.1
"Explosive environment" This section provides for the use of underground coal mines, as well as coal mine surface gas and/or coal dust environment type I
EPLMa-class equipment design, structure, testing and marking requirements.
This section applies to the environmental conditions. Atmospheric pressure 80kPa ~ 110kPa, ambient temperature -20 °C ~ 60 °C, the standard oxygen in the air
Content (volume ratio) .21%.
1.2
This section applies to coal mines, and coal mine surface gas and/or coal dust environment of all Class I EPLMa equipment
Design, construction, testing and marking of gas and non-electrical equipment.
1.3
This section also applies if the transmission cables, pipes and optical fibers form part of a device that is intended for use in hazardous gas and/or dust atmospheres
Some cables, pipes and fibers.
1.4
This section does not apply to mining cap lamp (GB 7957 otherwise provided).
Note 1. Since the energy required to ignite a dust cloud formed from pulverized coal and air is 600 times the energy required to ignite a gas/air mixture, this section assumes
If the structure of intrinsically safe "ia" circuits is safe in explosive gas/air environments, then the circuit will operate in a pulverized coal/air explosive atmosphere
Kind of safe.
Note 2. This section also gives guidance when designing equipment for use in explosive atmospheres other than those specified in 1.1 above. For this situation
In the meantime, additional tests are recommended to enable manufacturers to specify the conditions under which these devices apply to these exceptions.
Note 3. When explosive gas atmospheres occur in coal mines or on the ground, the risk of ignition must be limited to a minimum. In hazardous gas and/or coal dust environments,
In addition to Class I Ma Class equipment that workers must operate continuously, management may require the prohibition of certain Class Ma equipment.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB 3836.1-2010 Explosive atmospheres - Part 1. General requirements for equipment (IEC 60079-0.2007, MOD)
GB 3836.2-2010 Explosive atmospheres - Part 2. Equipment protected by flameproof enclosure "d" (IEC 60079-1-2007,
MOD)
GB 3836.4-2010 Explosive atmospheres - Part 4. Equipment protected by intrinsically safe "i" (IEC 60079-11.2006,
MOD)
GB 3836.7 Electrical apparatus for explosive gas atmospheres - Part 7. Sand filled "q" (GB 3836.7-2004, IEC 60079-5.
1997, IDT)
GB 3836.9-2014 Explosive atmospheres - Part 9. Equipment protected by encapsulation "m" (IEC 60079-18.2009, MOD)
GB 7957 safety requirements General requirements for miner's lamp (GB 7957-2003, IEC 62013-1.1999, NEQ)
GB 25286.1-2010 Non-electrical equipment for explosive atmospheres Part 1. Basic methods and requirements
GB 25286.5-2010 Non-electrical equipment for explosive atmospheres Part 5. Structural safety "c"
3 Terms and definitions
GB 3836.1-2010 defined and the following terms and definitions apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB 3836.1-2010 · GB 3836.2-2010 · GB 3836.4-2010 · GB 3836.7 · GB 3836.9-2014 · GB 25286.1-2010 · GB 25286.5-2010
Similar standards
How to Download GB/T 3836.23-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 7957-2023 — Safety technical requirement for cap lamps in coal mine
GB/T 3836.24-2017 — Explosive atmospheres -- Part 24: Equipment protection by special protection 's'
GB/T 3836.22-2023 — Explosive atmospheres - Part 22: Protection of equipment and transmission system using optical radiation