Valid

GB/T 3836.18-2024Explosive atmospheres - Part 18: Intrinsically safe electrical systems (English PDF)

爆炸性环境 第18部分:本质安全电气系统

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 3836.18-2024 in 30 minutes.

Issued by

State Administration for Market Regulation

Level / Type

National · Recommended

Issue date

March 15, 2024

Implementation date

October 1, 2024

Scope

GB/T 3836.18-2024 is the English-translated version of 爆炸性环境 第18部分:本质安全电气系统.

GB/T 3836.18-2024 — This document specifies special requirements for the design, structure, and assessment of intrinsically safe systems (explosion-proof type "i").

This document applies to intrinsically safe systems that are intended to be used in whole or in part in places where Class I, Class II or Class III Ex equipment is required.

Note 1: This document is used for the design and assessment of intrinsically safe systems; its personnel may be the manufacturer, third-party organization, expert consultant or end-user staff.

This document supplements and modifies the general requirements of GB/T 3836.1 and the intrinsic safety type of GB/T 3836.4. When the requirements of this document conflict with the requirements of GB/T 3836.1 or GB/T 3836.4, the requirements of this document take precedence.

The installation requirements of Class II or Class III intrinsically safe systems, which are designed in accordance with this document, are specified in GB/T 3836.15.

Note 2: GB/T 3836.15 currently does not specify the installation requirements for Class I; the installation requirements for Class I are under consideration.

Found what you need?

Document preview — GB/T 3836.18-2024

National Standard of the People's Republic of China

ICS
29.260.20

Issued by: State Administration for Market Regulation

Contents

  • Foreword...4
  • Introduction...9
  • 1 Scope...12
  • 2 Normative references...12
  • 3 Terms and definitions...13
  • 4 System descriptive document...14
  • 5 Classes and temperature groups...15
  • 6 Protection level...16
  • 6.1 General...16
  • 6.2 "ia" protection level...16
  • 6.3 "ib" protection level...16
  • 6.4 "ic" protection level...16
  • 7 Non-intrinsically safe circuits...17
  • 8 Interconnection lines/cables of intrinsically safe system...17
  • 8.1 General...17
  • 8.2 Cables containing a single intrinsically safe circuit...17
  • 8.3 Cables containing multiple intrinsically safe circuits...17
  • 9 Requirements for single-circuit and multi-circuit cables...18
  • 9.1 General...18
  • 9.2 Dielectric strength...18
  • 9.3 Intrinsic safety parameters of cables...19
  • 9.4 Conductive shielding...19
  • 9.5 Types of multi-circuit cables...19
  • 10 Enclosure...20
  • 11 Grounding and equipotential bonding of intrinsically safe systems...20
  • 12 Evaluation of intrinsically safe systems...21
  • 12.1 General...21
  • 12.2 Systems containing only devices certified in accordance with GB/T 3836.4...21

Foreword

This document was drafted in accordance with the provisions of GB/T 1.1-2020

"Directives for standardization - Part 1: Rules for the structure and drafting of

standardizing documents".

This document is Part 18 of GB(/T) 3836 "Explosive atmospheres". GB(/T) 3836 has

published the following parts:

- Part 1: General requirements;

- Part 2: Equipment protection by flameproof enclosures "d";

- Part 3: Equipment protection by increased safety "e";

- Part 4: Equipment protection by intrinsic safety "i";

- Part 5: Equipment protection by pressurized enclosure p;

- Part 6: Equipment protection by liquid immersion "o";

- Part 7: Equipment protection by powder filling "q";

- Part 8: Equipment protection by type of protection "n";

- Part 9: Equipment protection by encapsulation "m";

- Part 11: Material characteristics for gas and vapor classification - Test methods and

data;

- Part 12: Material characteristics for combustible dusts - Test methods;

- Part 13: Equipment repair, overhaul, reclamation and modification;

- Part 14: Classification of locations - Explosive atmospheres;

- Part 15: Electrical installations design, selection and erection;

- Part 16: Electrical installations inspection and maintenance;

- Part 17: Equipment protection by pressurized room "p" and artificially ventilated

room "v";

- Part 18: Intrinsically safe electrical systems;

- Part 20: Equipment with equipment protection level (EPL) Ga;

- Part 21: Application of quality management systems for Ex product manufacture;

- Part 22: Protection of equipment and transmission system using optical radiation;

- Part 23: Group I, category EPL Ma equipment intended to remain functional in

atmospheres endangered by firedamp and/or coal dust;

- Part 24: Equipment protection by special protection "s";

- Part 25: Requirements for process sealing between flammable process fluids and

electrical systems;

- Part 26: Electrostatic hazards - Guidance;

- Part 27: Electrostatic hazards - Test;

- Part 28: Non-electrical equipment for explosive atmospheres - Basic method and

requirements;

- Part 29: Non-electrical equipment for explosive atmospheres - Constructional

safety "c", control of ignition source "b", liquid immersion "k";

- Part 30: Equipment and components in explosive atmospheres in underground

mines;

- Part 31: Equipment dust ignition protection by enclosure "t";

- Part 32: Intrinsically safe systems with electronically controlled spark duration

limitation;

- Part 33: Equipment in adverse service conditions;

- Part 34: Equipment assemblies;

- Part 35: Classification of areas for explosive dust atmospheres;

- Part 36: Electrical safety devices for the control of potential ignition sources from

Ex Equipment.

This document replaces GB/T 3836.18-2017 "Explosive atmospheres - Part 18:

Intrinsically safe electrical systems". Compared with GB/T 3836.18-2017, in addition

to structural adjustments and editorial changes, the main technical changes are as

follows:

- CHANGE the content of the system description file (see Chapter 4; Chapter 4 of

the 2017 edition);

- CHANGE the requirements for categories and temperature groups, including the

original Chapter 7 ambient temperature ratings (see Chapter 5; Chapters 5 and 7 of

the 2017 edition);

Explosive atmospheres - Part 18: Intrinsically safe electrical

systems

1 Scope

This document specifies special requirements for the design, structure, and assessment

of intrinsically safe systems (explosion-proof type "i").

This document applies to intrinsically safe systems that are intended to be used in whole

or in part in places where Class I, Class II or Class III Ex equipment is required.

Note 1: This document is used for the design and assessment of intrinsically safe systems; its

personnel may be the manufacturer, third-party organization, expert consultant or end-user staff.

This document supplements and modifies the general requirements of GB/T 3836.1 and

the intrinsic safety type of GB/T 3836.4. When the requirements of this document

conflict with the requirements of GB/T 3836.1 or GB/T 3836.4, the requirements of this

document take precedence.

The installation requirements of Class II or Class III intrinsically safe systems, which

are designed in accordance with this document, are specified in GB/T 3836.15.

Note 2: GB/T 3836.15 currently does not specify the installation requirements for Class I; the

installation requirements for Class I are under consideration.

2 Normative references

The contents of the following documents constitute essential clauses of this document

through normative references in the text. Among them, for dated references, only the

version corresponding to that date applies to this document; for undated references, the

latest version (including all amendments) applies to this document.

GB/T 3836.1 Explosive atmospheres - Part 1: Equipment - General requirements

(GB/T 3836.1-2021, IEC 60079-0:2017, MOD)

GB/T 3836.4 Explosive atmospheres - Part 4: Equipment protection by intrinsic

safety "i" (GB/T 3836.4-2021, IEC 60079-11:2011, MOD)

GB/T 3836.15 Explosive atmospheres - Part 15: Electrical installations design,

selection and erection (GB/T 3836.15-2017, IEC 60079-14:2007, MOD)

GB/T 16657.2 Industrial communication networks - Fieldbus specifications - Part 2:

connection to the combined power source:

- Maximum external capacitance Co; and

- Maximum external inductance Lo; or

- Maximum inductance to resistance ratio L/R of the connecting cable.

Any test-based verification shall be performed using a spark test device in accordance

with GB/T 3836.4, taking into account the safety factor of the combined device.

The Ui, Ii, Pi of each device in the system shall be greater than or equal to the Uo, Io, Po

determined above, respectively.

Note 2: Appendix E illustrates the analysis used in the most common combination of linear

resistor-limited output power sources. Alternatively, GB/T 3836.15 provides a simplified

analysis for Class II circuits with protection level "ib" where the power source is an associated

device. The analysis may also include a spark ignition test in accordance with GB/T 3836.4.

12.5.2 Systems containing linear and non-linear power sources

The assessment of a system containing multiple power sources, one or more of which

are non-linear, shall be performed by a person with appropriate competence and

knowledge in the design and safety of non-linear intrinsically safe power sources. This

assessment cannot be based solely on open circuit voltage and short circuit current.

Any special conditions related to the system shall be clearly stated in the system

descriptive document.

If the intrinsically safe system contains multiple power sources, one or more of which

are non-linear, the assessment method described in Appendix E does not apply.

Appendix F describes how to perform a system analysis for a combination containing

a single non-linear power source.

Figure 1 illustrates the principle of system analysis.

If the power sources have different output voltages, any additional losses in the

regulating circuit need to be considered.

For non-linear sources, the combined Lo/Ro may be determined by testing the circuit

using the spark ignition test in GB/T 3836.4 with several discrete values of Lo and Ro,

using values of Ro ranging from nearly short circuit (maximum Io) to nearly open circuit

(Io near zero), and establishing a trend that ensures that Lo/Ro passes the spark ignition

test.

Note 1: Appendix F provides further guidance, including an assessment method that does not

require spark ignition testing for systems with no more than one non-linear source.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 3836.18-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 3836.18-2024

$705.00