GB/T 37733.3-2020Sensor networks—Remote personal health status monitoring—Part 3: Terminals technical requirements (English PDF)
传感器网络 个人健康状态远程监测 第3部分:终端技术要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37733.3-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 2, 2020
Implementation date
January 1, 2021
Scope
GB/T 37733.3-2020 is the English-translated version of 传感器网络 个人健康状态远程监测 第3部分:终端技术要求.
GB/T 37733.3-2020 is the Chinese standard "Sensor networks—Remote personal health status monitoring—Part 3: Terminals technical requirements".
Its scope clause reads: This part of GB/T 37733 specifies the technical requirements for personal health terminals in the personal health status remote monitoring system, mainly including Terminal requirements, interface requirements, safety requirements and other requirements.
This part is applicable to the design, production and use of personal health terminals in the remote monitoring system of personal health status in sensor networks.
Its clauses include terms and definitions; interface requirements; safety requirements; other requirements.
Found what you need?
Document preview — GB/T 37733.3-2020
National Standard of the People's Republic of China
- ICS
- 35.110
- Classification
- L 79
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions1
- 4 Overview2
- 5 Terminal requirements2
- 5.1 Appearance and structure requirements2
- 5.2 Functional requirements3
- 6 Interface requirements3
- 6.1 The interface between the terminal and the platform3
- 6.2 Interface between sensor nodes in the terminal3
- 6.3 Interface between the device in the terminal and the gateway3
- 7 Safety requirements3
- 7.1 Electrical safety3
- 7.2 Information Security4
- 8 Other requirements4
- 8.1 Electromagnetic compatibility requirements4
- 8.2 Reliability requirements5
- 8.3 Limit requirements for toxic and hazardous substances5
1 Scope
This part of GB/T 37733 specifies the technical requirements for personal health terminals in the personal health status remote monitoring system, mainly including
Terminal requirements, interface requirements, safety requirements and other requirements.
This part is applicable to the design, production and use of personal health terminals in the remote monitoring system of personal health status in sensor networks.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB 4943.1-2011 Information Technology Equipment Safety Part 1.General Requirements
GB/T 9254-2008 Information Technology Equipment Radio Disturbance Limits and Measurement Methods
GB 15629.11 Telecommunications and Information Exchange Between Information Technology Systems Specific Requirements for Local Area Networks and Metropolitan Area Networks Part 11.Wireless LAN Media Access Control and Physical Layer Specifications
GB/T 18268.26-2010 Electromagnetic compatibility requirements for electrical equipment for measurement, control and laboratory use Part 26.Special requirements for in vitro diagnostic (IVD) medical equipment
GB/T 26572 Limit requirements for restricted substances in electronic and electrical products
GB/T 30269.1-2015 Information Technology Sensor Network Part 1.Reference Architecture and General Technical Requirements
GB 31241-2014 Safety requirements for lithium-ion batteries and battery packs for portable electronic products
GB/T 37733.1-2019 Remote Monitoring of Personal Health Status in Sensor Network Part 1.General Technical Requirements
GB/T 37733.2-2020 Sensor network personal health status remote monitoring Part 2.Terminal and platform interface technical requirements
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Personal health information sensing terminal
An entity that is composed of personal health equipment and personal health gateway, and has the functions of personal vital sign data collection, storage and transmission product.
3.2 Personal health equipment
The physical entity used to collect and measure personal health data is one of the components of the terminal. It has data collection functions and can have
Data processing and storage capabilities.
3.3 Personal health sensor node
A sensor node used to collect personal health data.
c) There should be no spillage of the infusion;
d) The text, symbols, signs and various displays should be clear;
e) Structural parts and control components should be complete and free of mechanical damage;
f) If there is an indicator light, it should be clearly displayed;
g) The parts of the product should be fastened without looseness, pluggable parts should be connected reliably, switches, buttons and other control parts should be flexible and reliable, and the layout should be easy to use.
5.2 Functional requirements
The functional requirements of personal health equipment are as follows.
a) At least one sensor node should be included, with personal health information perception, data processing and packaging functions.
b) Support data caching function.
c) Display function. It should have backlight on/off function, power display function, and support touch function according to the needs of application scenarios.
d) It can support human-computer interaction functions, including but not limited to manual participation, status display, alarm, etc.
e) Time synchronization function. It can support background time synchronization and positioning passive mode time synchronization functions through the network.
f) Self-check function. Should have self-checking function and reminding function, which can include. communication status, main power status, status of other equipment connected to it, etc.
g) Equipment management function. It shall have the function of self-state management during operation, which may include model management, state monitoring, error reporting, and low-voltage reporting of personal health equipment.
h) Equipment remote management function. It should support remote configuration management, connection management and fault management; it should have the ability to support remote software upgrades.
i) Node management function. It can support remote configuration, connection management and fault management of nodes.
j) Power supply mode. Can support battery power supply and wireless power supply.
6 Interface requirements
6.1 Interface between terminal and platform
The interface between the terminal and the platform should meet the requirements of GB/T 37733.2-2020.
6.2 Interface between sensor nodes in the terminal
The interface between sensor nodes should meet the requirements of 4.1.3 of GB/T 30269.1-2015.It is advisable to choose between wireless sensor nodes near/
Short-distance wireless technology meets the requirements of low power consumption and low radiation; wired sensor nodes should choose interface technology that supports hot plugging.
6.3 The interface between the device in the terminal and the gateway
The interface between the device and the gateway can support wide area network communication technologies such as 3G/4G and low-power wide area network in addition to short/short-range wireless technology.
When supporting wireless LAN, it shall meet the relevant requirements of GB 15629.11.
7 Safety requirements
7.1 Electrical safety
7.1.1 Terminal electrical safety
The electrical safety requirements of the terminal should meet the requirements of GB 4943.1-2011.
7.1.2 Adapter security
For terminals with adapter accessories. The electrical safety requirements of the adapter should meet the relevant requirements of GB 4943.1-2011.
7.1.3 Safety of rechargeable lithium-ion batteries
The battery is a terminal for charging lithium ion. The safety requirements for rechargeable lithium-ion batteries should meet the relevant requirements of GB 31241-2014.
7.2 Information Security
7.2.1 Hardware Information Security
The terminal should have the ability to prevent physical attacks and prevent information leakage. Attack methods include but are not limited to non-invasive attacks, semi-invasive attacks
And intrusive attacks; the terminal's encryption module supports anti-side-pass attacks and resistance to error injection attacks.
7.2.2 Data Security
7.2.2.1 Data collection
The terminal or terminal application should collect user personal information when the user knows, controls, and is permitted.
7.2.2.2 Data transmission
The terminal should be encrypted during data transmission, and should not be encrypted with a fixed default key; it should be able to ensure that the data transmission process is not monitored, tampered and forged.
7.2.2.3 Data storage
For the local data storage of the terminal, it should be ensured that the data is not accessed illegally, and the database and local configuration files should be stored in local encryption.
For remote data storage of the terminal, before the terminal interacts with the background server, the terminal should conduct compliance with the background server.
User identity authentication should ensure the confidentiality and integrity of data when uploading and downloading data.
The terminal should have the ability to prevent physical attacks and prevent information leakage. Attack methods include but are not limited to non-invasive attacks, semi-invasive attacks
And intrusive attacks; the terminal's encryption module supports anti-side-pass attacks and resistance to error injection attacks.
8 Other requirements
8.1 Electromagnetic compatibility requirements
8.1.1 Electromagnetic disturbance
The electromagnetic disturbance limit of the equipment shall meet the requirements of Chapter 6 of GB/T 9254-2008.
8.1.2 Static discharge
When the equipment is used in a non-vehicle environment, the static discharge immunity requirements should meet the requirements of Chapter 6 of GB/T 18268.26-2010.
8.1.3 Electromagnetic radiation immunity
When the equipment is suitable for entering hospitals and other environments, the equipment's radio frequency electromagnetic field radiation immunity requirements should meet GB/T 18268.26-
2010 Chapter 6 regulations.
8.1.4 Power frequency magnetic field immunity
The equipment's power frequency magnetic field immunity requirements should meet the requirements of Chapter 6 of GB/T 18268.26-2010.
8.2 Reliability requirements
The mean time between failures (MTBF) of terminal equipment should not be less than 10000h.
8.3 Limit requirements for toxic and hazardous substances
When applicable, the limit of toxic and hazardous substances in the product should meet the requirements of GB/T 26572.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 37733.3-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 37733.1-2019 — Sensor networks—Remote personal health status monitoring—Part 1: General technical requirements
GB/T 37733.2-2020 — Sensor network—Remote personal health status monitoring—Part 2: Interface technical requirements between terminals and platform
GB/T 7251.4-2026 — Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)
Secure payment via Stripe
Payments accepted
GB/T 37733.3-2020
$105.00