GB/T 37155.1-2018Technical guidance of protection and control system on regional power grid—Part 1: Functional specification (English PDF)

区域保护控制系统技术导则 第1部分:功能规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37155.1-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 28, 2018

Implementation date

July 1, 2019

Scope

GB/T 37155.1-2018 is the English-translated version of 区域保护控制系统技术导则 第1部分:功能规范.

GB/T 37155.1-2018 is Part 1 of the technical guidelines for regional protection and control systems and gives their functional specification.

It sets the functional configuration and technical requirements of regional protection and control systems for terminal distribution networks of 110 kV and below, including those with distributed power sources: relay protection, safety and stability control and automatic switching to standby power, with the configuration principles and coordination of these functions.

Such a system adds coordinated control based on the information of several substations to the existing protection and automatic devices, and uses intelligent acquisition devices linked to the primary equipment by cable and to the protection devices by optical fibre.

Part 2 covers information interfaces and communication. It was issued on 28 December 2018 and has applied since 1 July 2019.

Found what you need?

Document preview — GB/T 37155.1-2018

National Standard of the People's Republic of China

ICS
29.240
Classification
K 45

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 System function positioning and overall requirements

Foreword

GB/T 37155 "Technical Guidelines for Regional Protection Control Systems" is divided into two parts.

--- Part 1. Functional specifications;

--- Part 2. Information interface and communication.

This part is the first part of GB/T 37155.

This part is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This part of GB/T 37155 specifies the regional protection control applied to the terminal distribution network (including distributed power supply) of 110kV and below.

The functional configuration and technical requirements of the system mainly include the relay protection, safety and stability control, and the configuration principle and matching of the standby power self-injection function. Relationship.

This section applies to 110kV and below voltage level regional protection control system, other voltage levels have the same grid power supply reliability The same type of grid area protection control system of the problem can be referred to for execution.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2900.49 Electrotechnical terminology power system protection

GB/T 14285 Technical Specification for Relay Protection and Safety Automatic Devices

GB/T 14598.300 General technical requirements for microcomputer transformer protection device

GB/T 26399 Power System Safety and Stability Control Technical Guidelines

DL/T 670 busbar protection device general technical conditions

IEC 61850 (all parts) Communication networks and systems for substations

3 Terms and definitions

The following terms and definitions as defined in GB/T 2900.49 apply to this document.

3.1 Regional protection control system

On the basis of the existing relay protection and safety automatic device configuration, in accordance with the improvement of protection functions, optimization of control strategies, and improvement of reliable power supply Sexual requirements include additional control functions including relay protection, stability control, and standby power supply self-injection for coordinated control of multiple substation information. The general term for the system that constitutes it.

3.2 Intelligent acquisition device

A smart device that integrates one or more spaced analog, digital signal acquisition and control signal outputs. With primary equipment Cable connection, and optical fiber connection with the regional protection control device to measure the primary equipment (such as. circuit breaker, knife gate, main transformer, etc.) Control and other functions.

4 System function positioning and overall requirements

The functional positioning and overall requirements of the regional protection control system are as follows. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37155.1-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37155.1-2018

$145.00