GB/T 36955-2018Technical specification for pre-insertion resistor of high- voltage direct current transmission using voltage sourced converters (VSC-HVDC) (English PDF)
柔性直流输电用启动电阻技术规范
This is a limited preview
Buy now to download the full PDF (21 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36955-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
July 1, 2019
Scope
GB/T 36955-2018 is the English-translated version of 柔性直流输电用启动电阻技术规范.
GB/T 36955-2018 is the Chinese technical specification for pre-insertion resistors, the starting resistors used in flexible DC transmission (VSC-HVDC) to limit the charging current of the voltage source converter while the converter station is energized.
It covers resistors on the AC side, placed on the network or valve side of the coupling or converter transformer, and on the DC side, at the DC bus or neutral bus.
The standard sets the conditions of use and installation, technical parameters, design and structure, type tests, routine factory tests and field tests, and the requirements for packaging, storage, installation, operation, maintenance and technical documentation.
Its annexes show typical resistor positions, design parameters and charging current waveforms. It can also be referred to for UPFC projects. It was issued on 28 December 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 36955-2018
National Standard of the People's Republic of China
- ICS
- 29.240.01
- Classification
- F 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Conditions of use and installation conditions
- 5 Technical parameters
- 6 Design and Structure
- 7 type test
- 8 Factory test (routine test)
- 9 Field test
- 10 Packaging, storage, installation, operation and maintenance and technical information
- Appendix A (informative) Schematic diagram of the starting resistor position
- Appendix B (informative) Typical design parameters for resistors
- Appendix C (informative) Startup resistance typical charging current waveform
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the conditions of use and installation conditions, technical parameters, design and structure, type test, and start-up resistance of flexible DC transmission. Factory test, field test, packaging, storage, installation and maintenance and technical information.
This standard applies to starting resistors for flexible DC transmission, including AC side starting resistors and DC side starting resistors, unified power flow controller (UPFC) engineering AC and DC side starting resistor can be referred to.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 311.1-2012 Insulation coordination Part 1: Definitions, principles and rules
GB/T 4208-2017 enclosure protection grade (IP code)
GB/T 11022-2011 Common technical requirements for high voltage switchgear and control equipment standards
GB/T 13540 high-voltage switchgear and control equipment for seismic requirements
GB/T 16927.1-2011 High voltage test techniques - Part 1: General definitions and test requirements
GB/T 30547-2014 High-voltage DC transmission system filter resistor
Design specification for overvoltage protection and insulation coordination of GB/T 50064 AC electrical installations
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Start resistor
The flexible DC converter station does not control the resistance input during the charging process to reduce the charging current of the voltage source converter.
3.2 AC side starting resistor
A starting resistor arranged on the mesh side or the valve side of the coupling/commutation transformer according to system conditions.
Note: Refer to Appendix A for the typical position of the AC side starting resistor. The starting resistor arranged on the mesh side of the coupling/commutation transformer is called the AC network side starting power The starting resistor placed on the valve side of the coupling/commutation transformer is called the AC valve side starting resistor.
3.3 DC side starting resistor
The starting resistor is placed at the DC bus or neutral bus of the voltage source converter according to system conditions.
Note: Refer to Appendix A for the typical position of the DC side starting resistor.
3.4 Resistor module
Assembled in a single casing or jacket by series or parallel connection by a plurality of resistive elements, bonding materials and supporting materials The assembly of the terminals.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 13540Seismic qualification for high voltage switchgear and controlgear
- GB/T 16927.1-2011High-voltage test techniques -- Part 1: General definitions and test requirements
- GB/T 30547-2014Filter resistor for high voltage direct current (HVDC) transmission system
- GB/T 50064Code for design of overvoltage protection and insulation coordination for AC electrical installations
GB/T 311.1-2012
Similar standards
How to Download GB/T 36955-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13540-2009 — Seismic qualification for high voltage switchgear and controlgear
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements
GB/T 4208-2017 — Degrees of protection provided by enclosures (IP code)
Secure payment via Stripe