Valid

GB/T 36122-2018Maintenance and management of municipal fire water supply facilities (English PDF)

市政消防给水设施维护管理

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 36122-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 14, 2018

Implementation date

December 1, 2018

Scope

GB/T 36122-2018 is the English-translated version of 市政消防给水设施维护管理.

GB/T 36122-2018 sets out how municipal fire water supply facilities are to be maintained and managed. It covers municipal fire hydrants, fire water cranes and the facilities that draw fire water from natural sources such as rivers, lakes, seas and reservoirs.

Its clauses deal with daily operation management, repair and renewal, the signs that mark the facilities, information management, use and supervision.

Among the terms it defines are the municipal fire hydrant, connected to the municipal water supply and made up of valves, outlets and plugs, and the facility sign showing location, technical parameters and management details.

It guides local governments, the departments concerned and water supply units in carrying out their maintenance duties, and other fire water supply facilities may follow it for reference. It was issued on 14 May 2018 and has applied since 1 December 2018.

Found what you need?

Document preview — GB/T 36122-2018

National Standard of the People's Republic of China

ICS
13.220.10
Classification
C 83

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General
  • 5 daily operation management
  • 6 repair and update
  • 7 Logo Management
  • 8 Information Management
  • 9 use
  • 10 Supervision
  • Reference

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Introduction

The municipal fire water supply facility is an important public fire protection infrastructure for water supply for fire fighting and rescue, and strengthens the maintenance and management of municipal fire water supply facilities.

It plays an important role in improving the ability of cities to resist fires. In order to guide local people's governments at all levels, relevant departments and water supply units to perform peacekeeping To protect and administer the responsibility of municipal fire water supply facilities, and to ensure the simultaneous promotion of urban fire fighting and rescue capacity and new urbanization construction, this standard has been formulated.

1 Scope

This standard stipulates the daily operation management, repair and renewal of municipal fire water supply facilities, sign management, information management, use and Supervision.

This standard is applicable to the maintenance and management of municipal fire water supply facilities such as municipal fire hydrants, fire water cranes and natural water source fire water intake facilities.

The maintenance and management of his fire water supply facilities can be referred to.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2893.1-2013 Graphical symbols - Safety colours and safety signs - Part 1 in principle

GB/T 2893.3-2010 Graphical symbols - Safety colours and safety signs - Part 3

GB 2894-2008 Safety signs and guidelines for their use

GB 5768.3-2009 Road traffic signs and markings - Part 3. Road traffic markings

GB 13495.1-2015 Fire safety signs Part 1. Signs

GB 15630-1995 Fire safety sign setting requirements

GB/T 18578 Urban Geographic Information System Design Specification

GB/T 50328 Construction Engineering Document Filing Specification

GB 50974 Technical specification for fire water supply and fire hydrant systems

GB 51038-2015 Code for setting up urban road traffic signs and markings

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Municipal fire water supply facility

Municipal fire hydrants for firefighting and rescue, fire water cranes, and fire water intake facilities for natural water sources such as rivers, rivers, lakes, seas, and reservoirs.

3.2 Municipal fire hydrant

It is connected to the municipal water supply system and is a public fire water supply device consisting of valves, water outlets and plugs.

Note: Refer to GB 4452-2011 for the definition of outdoor fire hydrants.

3.3 Natural water source fire water intake facility

Relying on natural water sources such as rivers, rivers, lakes, seas, and reservoirs, facilities for water supply by fire engines (pumps) or water supply to fire engines (pumps).

3.4 Municipal fire water supply facility sign

Indicates the location, technical parameters, management and other information of the municipal fire water supply facilities, and has fire safety signs indicating and prohibiting.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 36122-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 36122-2018

$185.00