GB/T 36045-2018Supervision specification of unit capacity expansion retrofit for coal-fired power plants (English PDF)
燃煤火电机组增容改造监管规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36045-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 36045-2018 is the English-translated version of 燃煤火电机组增容改造监管规范.
GB/T 36045-2018 is the Chinese specification for supervising capacity expansion retrofits of coal-fired thermal power units.
It sets the prerequisites a unit must meet before its capacity is increased, how the capacity is verified after the retrofit, the performance and operating requirements that apply afterwards, and how the retrofit is declared and approved.
It defines capacity expansion and the coal consumption for power supply, calculated in grams of standard coal per kilowatt-hour from boiler, turbine and pipe efficiencies and the plant's own electricity rate.
Its introduction explains why it was written: some expanded units could run at their new rating only for short periods, with poor economy, large life loss and a marked drop in primary frequency regulation. It was issued on 15 March 2018 and has applied since 1 October 2018.
Found what you need?
Document preview — GB/T 36045-2018
National Standard of the People's Republic of China
- ICS
- 27.100
- Classification
- F 20
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Prerequisites for capacity increase of coal-fired thermal power units
- 5 Capacity verification of coal-fired thermal power units after capacity expansion
- 6 Performance and Operation Requirements after Capacity Expansion of Coal-fired Thermal Power Units
- 7 Declaration and Approval of Capacity-Enhancing Reform of Coal-fired Thermal Power Units
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
In recent years, the capacity expansion of coal-fired thermal power units has generally been carried out throughout the country. There are two main motives for power generation companies to implement capacity expansion.
First, under the planned system, increasing the capacity of the unit can be used to obtain more power generation plan targets, so as to obtain additional benefits;
Capacity transformation, increase power generation output, reduce coal consumption and improve economic efficiency. The motivation is different, and the operation method and the final effect of implementing the capacity expansion reform are not with. Due to the lack of a unified regulatory standard, the increase in capacity of units has emerged in operational procedures, technical indicators, safe operation, and practical results.
Problems, such as capacity expansion of some units can only be operated in a short period of time under certain operating conditions, poor economic performance, large life loss, primary frequency modulation capability and phase-in operation The capacity has dropped significantly. In order to ensure the orderly expansion of the scientific and normative regulations for increasing capacity and to ensure the safe and economical operation of the power system, the Based on the relevant technical standards of the electric power industry and the laws and regulations of electric power supervision, the regulatory standards for the expansion of coal-fired thermal power units have been formulated.
1 Scope
This standard stipulates the applicable scope, modification conditions, capacity test and performance requirements and capacity of the capacity-increasing transformation of coal-fired thermal power units. Appraisal of regulatory technical indicators and methods in such areas.
This standard applies to the regulation of the expansion of coal-fired thermal power units.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 18149 centrifugal pump, mixed flow pump and axial pump hydraulic performance test specification
GB/T 30370 Primary frequency modulation test and performance acceptance guide for thermal power generating units
GB 50660 Design Specification for Large and Medium-sized Thermal Power Plants
Field Performance Test of DL/T 469 Power Station Boiler Fan
DL/T 711 Turbine Regulation Control System Test Guidelines
DL/T 1166 Field Test Guide for Large Generator Excitation System
DL/T 1210 Thermal power plant automatic power generation control performance test acceptance procedures
DL/T 1235 synchronous generator prime mover and its regulation system parameters measurement and modeling guidelines
DL/T 1523 Synchronous Generator Phase Test Guidelines
DL/T 5295 Regulations for Acceptance and Evaluation of Commissioning Quality of Units for Thermal Power Generation Construction Engineering
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Capacity expansion
The power generation enterprises upgrade the coal-fired thermal power units to increase the generating capacity of the units and realize energy conservation and consumption reduction.
3.2 Coal consumption for power supply
In the statistical calculation period, the average amount of standard coal consumed by each generating unit to provide 1kWh of electrical energy is calculated according to formula (1).
In the formula:
Bg --- Coal consumption for power supply in grams of standard coal per kilowatt-hour (gce/kWh);
Lfcy --- power plant electricity rate, expressed as a percentage (%);
eta g --- boiler efficiency, expressed as a percentage (%);
eta q --- turbine efficiency, expressed as a percentage (%);
eta gd --- Pipe efficiency, expressed as a percentage (%).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 18149Centrifugal,mixed flow and axial pumps—Code for hydraulic performance tests—Precision class
- GB/T 30370Guide of primary frequency control test and performance acceptance for thermal power generating units
- GB 50660Code for design of fossil fired power plant
- DL/T 469Field Performance Test of Power Station Boiler Fan
- DL/T 711Turbine regulation security system test guidelines
- DL/T 1166Field test guidelines of excitation system for large synchronous generators
DL/T 5295
Similar standards
How to Download GB/T 36045-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 1166-2012 — Field test guidelines of excitation system for large synchronous generators
DL/T 1210-2025 — Code for Testing and Acceptance of Automatic Generation Control Performance of Thermal Power Plant
DL/T 1235-2019 — Guide for measurement and modeling of synchronous generator prime mover and its regulating system parameters