GB/T 36015-2018Non-destructive testing instruments—Performance and testintg rules of industrial digital X-ray imaging system (English PDF)
无损检测仪器 工业X射线数字成像装置性能和检测规则
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36015-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 36015-2018 is the English-translated version of 无损检测仪器 工业X射线数字成像装置性能和检测规则.
GB/T 36015-2018 lays down the performance requirements and testing rules for industrial digital X-ray imaging systems used in non-destructive testing.
It covers the working principle, from the conversion of X-rays into electrical signals to analog-digital conversion, and the equipment requirements for the computer system, monitor, image storage and image processing software.
At system level it requires a resolution better than 1.5 LP/mm and an IQI sensitivity better than 2.0%, with the test methods given in Annexes A and B. It also describes the test procedure, including geometrical amplification and image quality checks with wire-type IQIs, together with inspection rules and marking, packaging, transportation and storage.
It applies to systems that inspect metallic and non-metallic materials. It was issued on 15 March 2018 and has applied since 1 October 2018.
Found what you need?
Document preview — GB/T 36015-2018
National Standard of the People's Republic of China
- ICS
- 19.100
- Classification
- N 78
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions5
- 4 Principle6
- 5 Equipment requirements6
- 6 Test procedure9
- 7 Inspection rules11
- 8 Marking, packaging, transportation and storage13
- Annex A (Normative) Test method of system resolution15
- Annex B (Normative) IQI sensitivity test18
1 Scope
This Standard specifies the principle, equipment requirements, test procedure, testing rules, marking, packaging, transportation and storage of industrial digital X-ray imaging systems.
This Standard applies to industrial digital X-ray imaging systems for testing metallic materials and non-metallic materials.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition dated applies to this document. For undated references, the latest edition of the referenced documents (including all amendments) applies to this document.
GB/T 191, Packaging - Pictorial marking for handling of goods
GB/T 12604.2, Non-destructive testing - Terminology - Terms used in radiographic testing
GB/T 13384, General specifications for packing of mechanical and electrical product
GB/T 17618, Information technology equipment - Immunity characteristics - Limits and methods of measurement
GB 18871, Basic standards for protection against ionizing radiation and for the safety of radiation sources
GB/T 25480, Basic environmental conditions and testing methods for transportation and storage of instruments
GB/T 26837-2011, Non-destructive testing instruments - Stationary type and movable type industrial X-ray radiographic equipment
JB/T 7902-2015
3 Terms and definitions
3.7 High voltage ripple coefficient
Peak value of alternating components in high voltage generated by X-ray system.
NOTE: Ripple coefficient = ripple voltage/output voltage.
3.8 System total unsharpness
NOTE: The smaller the unsharpness is, the clearer the details are, which is expressed in mm.
3.9 Image SNR
Ratio of statistical standard deviations of average signals to signals of the zone in some zone of test images.
3.10 Sensitivity of IQI
Percentage of the diameter of IQI identifiable finest wire to the thickness of object to be tested in the central zone of images.
4 Principle
4.1 Photovoltaic conversion
The process in which X-ray is received by a receiving-conversion device and converted into electrical signals.
4.2 Analog-digital conversion
The process in which analog signals are converted into digital signals.
5 Equipment requirements
5.1 General
5.3.3
System image grade shall not be lower than 256.
5.4 Computer systems
5.4.1 Computer configuration
Desktop computers, image workstations or notebook computers are preferably used; for poor working environment, industrial personal computers can be used.
5.4.2 CRT monitor
CRT monitors are preferably used, whose dot pitch is not greater than 0.26 mm and refresh rate is greater than 75 Hz.
5.4.3 Image storage
5.4.3.1 Stored digital images shall include work piece number, image name, transmission thickness, technological parameter, date and other effective information and shall not be modified. Necessary information can be displayed along with images.
5.4.3.2 Images shall not be modified or deleted after storage; storage devices for a long term storage are preferably used.
5.4.3.3 Original, unprocessed data shall be stored in image storage.
5.4.4 Image processing software
5.4.4.1 It shall meet the technical standards specified for products to be tested.
5.4.4.2 It shall include image acquisition modules, image processing modules and image display modules; other functional modules such as image auxiliary evaluation and database management, are recommended to be added as required by actual test.
5.4.4.3 It shall have image geometrical dimensions and measurement and defect positioning functions.
5.5 System requirements
5.5.1 Resolution
The system resolution of X-ray digital imaging devices shall be better than 1.5 LP/mm; the resolution test method shall be as specified in Annex A.
5.5.2 Sensitivity of IQI
The sensitivity of IQI shall be better than 2.0%; the IQI sensitivity test method shall be as specified in Annex B.
6 Test procedure
6.4.1 Geometrical amplification
In accordance with the relationships between the relative positions of X-ray generator (source), work piece to be tested and X-ray receiving-conversion device, see equation (1) for the geometrical amplification factor: where, M - the geometrical amplification factor;
L1 - the distance from the focus of X-ray generator to the surface of work piece to be tested;
L2 - the distance from the surface of work piece to be tested to the surface of ray receiving-conversion device.
6.4.2 Selection of amplification factor M
For the optimum amplification factor see equation (2): where, Mopt - the optimum amplification factor;
U - the inherent system unsharpness;
d - the focus size.
6.5 Image quality
6.5.1 Test method
Use metal wire IQI to test image quality.
6.5.2 Sensitivity of IQI
Use the minimum identifiable wire diameter of geometric metal wire IQI to evaluate test sensitivity.
6.5.3 Improving image quality
The method for improvement of image quality include: […]
8 Marking, packaging, transportation and storage
8.1 Marking
Nameplate shall include:
a) type specifications and product name;
b) major technical parameters;
c) manufacturer name, address and trademark;
d) data and number of production;
e) mark of conformity.
8.2 Packaging
8.2.1 Systems shall be provided with composite packaging, as specified in GB/T 13384.
8.2.2 The words and marks on the wall of packaging boxes shall be legible and indelible which shall not be blurred because of rubbing in handling or rain. The content shall include at least:
a) manufacturer name;
b) product name and type specifications;
c) name and address of receiver, and name and address of shipper;
d) packaging volume (L×W×H);
e) packaging boxes shall be marked with the words such as "upward", "fragile", "keep dry" and "do not roll", or the words or symbols for packaging, transportation and storage specified in GB/T 191;
f) number and name of product standards implemented.
8.2.3 Packaging boxes shall enclose the following accompanying documents:
a) packing list;
b) conformity certificate;
c) instruction manual;
d) list of accessory (spare) parts attached.
Annex A (Normative) Test method of system resolution
A.3 Test method for system resolution of X-ray digital imaging devices
Place an X-ray test image resolution tester closely against the surface center area of the input screen of the X-ray detector, with grid bars forming an angle of 90° with the horizontal position; carry out transillumination under the following test conditions:
a) the distance from the focus of X-ray tube to the surface of X-ray detector input screen is not less than 500 mm;
b) select appropriate tube voltage and tube current to ensure images have appropriate degrees of brightness and contrast.
A.4 Determination of X-ray digital imaging system resolution and system unsharpness
A.4.1 Determination of X-ray digital imaging system resolution
On the display screen, observe the image of X-ray test image resolution tester; observe a line pair where grid bars just start to separate, and then the value corresponding to the line pair is system resolution.
A.4.2 Determination of system unsharpness
On the display screen, observe the image of X-ray test image resolution tester; observe a line pair where grid bars just start to coincide, and then the grid bar width corresponding to the line pair is the inherent system unsharpness. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 12604.2Non-destructive testing -- Terminology -- Terms used in radiographic testing
- GB/T 13384General specifications for packing of mechanical and electrical product
- GB 18871Basic Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources
- GB/T 25480Basic environmental conditions and testing methods for transportation and storage of instruments
- GB/T 26837-2011Non-destructive testing instruments - Stationary type and movable type industrial X-ray radiographic equipment
GB/T 17618
Similar standards
How to Download GB/T 36015-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 18871-2002 — Basic Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources
GB/T 12604.2-2005 — Non-destructive testing -- Terminology -- Terms used in radiographic testing
GB/T 13384-2008 — General specifications for packing of mechanical and electrical product
Secure payment via Stripe
Payments accepted
GB/T 36015-2018
$125.00