Valid

GB/T 35957-2018Determination of prohibited substances cesium-137, cesium-134 in cosmetics—Gamma spectrometry (English PDF)

化妆品中禁用物质铯-137、铯-134的测定 γ能谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35957-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

February 6, 2018

Implementation date

September 1, 2018

Scope

GB/T 35957-2018 is the English-translated version of 化妆品中禁用物质铯-137、铯-134的测定 γ能谱法.

GB/T 35957-2018 is the Chinese national gamma spectrometry method for determining cesium-137 and cesium-134, both prohibited substances, in cosmetics.

The sample is placed directly in a measurement box of fixed shape and volume, and the intensity of the characteristic gamma peaks, at 661.6 keV for cesium-137 and 604.7 keV for cesium-134, is compared with that of a standard to give the specific activity.

The standard covers the reagents and materials, the gamma spectrometer, the measurement of standard solutions and samples, the blank test with water, the calculation of results, recovery, precision and allowable differences, with an informative annex showing the reference spectra.

It applies to powder, cream, lotion and liquid cosmetics, with a lower detection limit of 10 Bq/kg. It was issued on 6 February 2018 and has applied since 1 September 2018.

Found what you need?

Document preview — GB/T 35957-2018

National Standard of the People's Republic of China

ICS
71.100.70
Classification
Y 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative references5
  • 3 Principle5
  • 4 Reagents and materials5
  • 5 Instruments and equipment6
  • 6 Analytical procedures6
  • 7 Calculation of results7
  • 8 Recovery rate and precision8
  • 9 Allowance8
  • Annex A (informative) Gamma energy spectrum of cesium-137, cesium-134 standard solutions9

1 Scope

This Standard specifies reagents and materials, instruments and equipment, analytical procedures, calculation of results, recovery rate and precision, allowable differences, etc. of gamma spectrometry determination method for prohibited substances cesium-137, cesium-134 in cosmetics.

This Standard is applicable to the determination of cesium-137, cesium-134 in powder, cream, lotion, liquid cosmetics.

The lower detection limit of cesium-137, cesium-134 in this Standard is 10 Bq/kg.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6682, Water for laboratory use; Specifications

3 Principle

The sample is directly dosed into a sample box of a certain shape and volume.

Measure gamma ray characteristic peak intensity of cesium-137, cesium-134 on gamma spectrometer. Compare with standard product so as to determine the radiation specific activity of cesium-137, cesium-134.

4 Reagents and materials

Unless otherwise stated, the reagents used in this method are analytically pure and the water is the laboratory grade three water specified in GB/T 6682.

4.1 2% nitric acid.

4.2 Standard sample. cesium-137, cesium-134 standard solutions.

6 Analytical procedures

6.2.2 Standard solution measurement

Take a certain amount (about 5Bq respectively) of cesium-137, cesium-134 standard stock solutions. Add into the weighed sample measurement box. And add water to make the amount of the solution as 50 g (to the nearest of 0.1g).

Cover, seal and mix well. The activity of cesium-137, cesium-134 in the sample box shall be calculated according to the amount of suction. Radiation decay correction shall be performed according to the fixed value date and date of use.

Place the sample box on the gamma spectrometer detector. Place the detector with the center axis of the sample box in a straight line. The measurement live time can be set according to the efficiency of the instrument. However, it shall be ensured that the peak area of the characteristic energy peak is not less than 1000. After the end of the measurement, the measured live time, the characteristic energy peak of cesium-137 (energy of 661.6 keV), and the peak area of the characteristic energy peak of cesium-134 (604.7 keV) shall be recorded. For the gamma energy spectrum of the cesium-137, cesium-134 standard solutions, see Figure A.1 in Annex A.

6.2.3 Sample measurement

Place the sample measurement box on the gamma spectrometer detector. Its position shall be consistent with the position of the standard solution measurement. The measurement live time is generally around 10000 s. The measurement live time can be adjusted according to the detector efficiency and the radionuclide content in the sample under the premise of ensuring the quantitative detection limit. After the end of the measurement, the measured live time, the characteristic energy peak of cesium-137 (energy of 661.6 keV), and the peak area of the characteristic energy peak of cesium-134 (604.7 keV) shall be recorded.

6.3 Blank test

Blank test uses 50 g of water as a sample. Carry out the test according to the above measurement conditions and procedures.

7 Calculation of results

Calculate according to equation (1). The calculation result retains 2 significant digits. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 35957-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35957-2018

$75.00