GB/T 35954-2018Determination of 10 whitening and freckle-removing components in cosmetics—High performance liquid chromatography (English PDF)
化妆品中10种美白祛斑剂的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35954-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35954-2018 is the English-translated version of 化妆品中10种美白祛斑剂的测定 高效液相色谱法.
GB/T 35954-2018 is the Chinese national method for measuring ten whitening and freckle-removing ingredients in cosmetics by high performance liquid chromatography.
The substances covered are magnesium ascorbyl phosphate, ascorbyl glucoside, beta-arbutin, kojic acid, nicotinamide, 3-O-ethylascorbic acid, potassium methoxysalicylate, raspberry glucoside, dipotassium glycyrrhizinate and 4-butyl resorcinol.
The sample is extracted ultrasonically with potassium dihydrogen phosphate solution, with a dichloromethane dispersion step for water-in-oil, wax-based and powder products, then centrifuged, filtered and analysed on a liquid chromatograph with a diode array detector.
The standard gives the reagents, instruments, sample preparation, calibration, qualitative confirmation, calculation, recovery, precision and allowable difference, and applies to water-based, lotion, cream, gel, wax-based and powder cosmetics. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35954-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Method summary4
- 4 Reagents and materials5
- 5 Instruments and equipment6
- 6 Analytical procedures6
- 7 Calculation of result8
- 8 Recovery and precision9
- 9 Allowable difference9
- Annex A (informative) Detection limit and limit of quantitation of 10 whitening and freckle-removing components10
- Annex B (informative) Chinese name, INCI name, CAS accession number, molecular formula, structural formula and relative molecular mass of the reference substance11
- Annex C (informative) Liquid chromatogram of standard solution of 10 whitening and freckle-removing components14
1 Scope
This Standard specifies reagents and materials, instruments and equipment, analytical procedures, calculation of results, recovery and precision, allowable difference, etc. for high performance liquid chromatography of 10 whitening and freckle-removing components (magnesium ascorbyl phosphate, ascorbyl glucoside, beta-arbutin, kojic acid, nicotinamide, 3-O-ethylascorbic acid, potassium methoxysalicylate, raspberry glucoside, dipotassium glycyrrhizinate, 4-butyl resorcinol) in cosmetics.
This Standard applies to the determination of whitening and freckle-removing components in water-based, lotion, cream, gel, wax-based, powder-based cosmetics.
For the detection limits and quantification limits of this Standard method, see Table A.1 in Annex A.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Method summary
The sample takes potassium dihydrogen phosphate solution as extraction solvent. Perform direct ultrasonic extraction of water-based samples and oil-in-water samples. Water-in-oil samples, wax-based, and powder-based samples are dissolved and dispersed in dichloromethane, and then extracted with ultrasonic solvent. Perform centrifugation, filtration through a 0.22µm water filter.
Inject solution into a liquid chromatograph equipped with a diode array detector.
5 Instruments and equipment
5.1 High performance liquid chromatograph equipped with diode array detector (DAD).
5.2 Centrifuge. >9500r/min.
5.3 Analytical balance. resolutions are 0.0001g and 0.001g.
5.4 PH meter.
5.5 Vortex mixer.
5.6 Ultrasonic cleaner.
5.7 Water microporous membrane. 0.45µm.
6 Analytical procedures
6.1 Sample processing
6.1.1 Preparation of water-based, oil-in-water samples
Weigh 0.5g of (to the nearest of 0.001g) sample in a 50mL colorimetric tube.
Add 30mL of potassium dihydrogen phosphate solution (4.4). Conduct vortex oscillation until the sample is completely dispersed. Perform ultrasonic extraction for 20min. Transfer to a 50mL volumetric flask. Use potassium dihydrogen phosphate solution (4.4) to set volume to the scale. After mixing evenly, take an appropriate amount of solution into the centrifuge tube.
Centrifuge at 9500r/min for 5min. Take the upper aqueous phase solution after centrifugation. Filter through a 0.45µm water filter, the filtrate is to be determined.
6.1.2 Preparation of water-in-oil, wax-based, powder-like samples
Weigh approximately 0.5g of (to the nearest of 0.001g) sample in a 50mL stoppered centrifuge tube. Add 2.5mL of dichloromethane (4.2). Vortex until the sample is completely dispersed (if a small amount of sample is not dispersed, it can be sonicated to complete dispersion). Add 20mL of potassium dihydrogen phosphate solution (4.4). Perform ultrasonic extraction for 20min, vortexing for 1min, centrifugation at 9500r/min for 5min. Remove the supernatant into a 50mL volumetric flask. Add 20mL of potassium dihydrogen phosphate solution (4.4). Vortex for 1min, centrifuge at 9500r/min for 5min, and combine the supernatant into a 50mL volumetric flask.
6.2.3 Specimen determination
The sample solution to be tested (6.1) is sequentially injected into the liquid chromatograph. Determine according to chromatographic conditions (6.2.1).
Record the retention time and peak area of the chromatographic peak.
Calculate the content of the target compound in the sample solution according to the standard curve. The response of the measured object in the sample solution shall be within the linear range of the standard curve. Specimen exceeding the linear range may be diluted with potassium dihydrogen phosphate solution (4.4) and then determined.
NOTE: In order to ensure the accuracy of specimen quantification, try to complete the test process within 12h.
6.2.4 Qualitative confirmation
Perform qualitative determination of sample by liquid chromatograph. When the sample is being determined, if the retention time of the peak of the tested whitening and freckle-removing component is consistent with the standard, and the chromatogram of the sample after subtracting the background, the UV absorption of the substance is consistent with the UV absorption of the standard, it can be preliminarily determined that the sample contains the measured whitening and freckle-removing component. If necessary, other methods are needed to confirm.
6.3 Blank test
Except for not weighing samples, they are carried out according to the above measurement conditions and procedures.
6.4 Parallel test
According to the above steps, perform parallel test determination of the same sample.
7 Calculation of result
The content of whitening and freckle-removing component in the sample is calculated by the following formula. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35954-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35954-2018
$125.00