Valid

GB/T 35949-2018Determination of prohibited aristolochic acid A in cosmetics—High performance liquid chromatography (English PDF)

化妆品中禁用物质马兜铃酸A的测定 高效液相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35949-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

February 6, 2018

Implementation date

September 1, 2018

Scope

GB/T 35949-2018 is the English-translated version of 化妆品中禁用物质马兜铃酸A的测定 高效液相色谱法.

GB/T 35949-2018 is a high performance liquid chromatography method for determining aristolochic acid A, a substance prohibited in cosmetics. It applies to skin care products such as creams, lotions and toning lotions, with a detection limit of 0.3 mg/kg and a limit of quantification of 1.0 mg/kg.

The sample is extracted with methanol in an ultrasonic bath, filtered and analysed on a liquid chromatograph with a UV detector, using external standard quantification against a calibration curve from 1.0 µg/mL to 50.0 µg/mL.

The standard also covers reagents, instruments, calculation of results, recovery and precision, and the allowable difference between parallel tests. Positive results can be confirmed by liquid chromatography-mass spectrometry, whose conditions are given in Annex C. It was issued on 6 February 2018 and has applied since 1 September 2018.

Found what you need?

Document preview — GB/T 35949-2018

National Standard of the People's Republic of China

ICS
71.100.70
Classification
Y 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative references5
  • 3 Principle of high performance liquid chromatography5
  • 4 Reagents and materials5
  • 5 Instruments and equipment6
  • 6 Analysis procedures6
  • 7 Calculation of result7
  • 8 Recovery and precision8
  • 9 Allowable difference8
  • Annex A (informative) Chinese name, CAS number, molecular formula, relative molecular mass, chemical structure of reference substance9
  • Annex B (informative) Liquid chromatogram of aristolochic acid A standard solution10
  • Annex C (informative) Confirmation test11

1 Scope

This Standard specifies reagents and materials, instruments and equipment, analysis procedures, calculation of result, recovery and precision, allowable difference, etc. for high performance liquid chromatography for prohibited aristolochic acid A in cosmetics.

This Standard is applicable to the determination of aristolochic acid A in skin care cosmetics such as creams, lotions, toning lotions.

The detection limit of this Standard method is 0.3mg/kg, and the limit of quantification is 1.0mg/kg.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6682, Water for analytical laboratory use - Specification and test methods

3 Principle of high performance liquid chromatography

The sample is ultrasonically extracted and filtered with methanol and detected by high performance liquid chromatograph equipped with a UV detector. Quantify by external standard method.

4 Reagents and materials

Unless otherwise stated, all reagents are analytically pure, and the water is the grade one water specified in GB/T 6682.

4.1 Methanol. chromatographically pure.

4.2 Glacial acetic acid.

6 Analysis procedures

6.3 Drawing of calibration curve

Respectively take 0.1mL, 0.5mL, 1.0mL, 2.0mL, 5.0mL of standard stock solutions (4.4). Use grade one water to set volume to 100mL. Prepare the standard working solutions of which the concentrations are 1.0µg/mL, 5.0µg/mL, 10.0µg/mL, 20.0µg/mL, 50.0µg/mL. Take standard working solutions at all levels into the high performance liquid chromatograph. Draw a calibration curve with peak area and solution concentration. For the liquid chromatogram of aristolochic acid A standard solution, see Figure B.1 in Annex B.

6.4 Sample determination

Take the sample solution (6.1) into the high performance liquid chromatograph.

Determine the nature according to peak retention time and UV spectrum.

Record chromatographic peak area. Obtain the corresponding concentration of aristolochic acid A from the calibration curve.

6.5 Qualitative confirmation

Conduct qualitative determination of sample by liquid chromatograph. When performing sample determination, if the detected peak value of the aristolochic acid A is consistent with the standard substance, and the sample chromatogram after deducting the background, the UV absorption spectrum of the material is consistent with the UV absorption spectrum of the reference material, it shall initially confirm the presence of aristolochic acid A. If necessary, positive samples shall be confirmed by liquid chromatography-mass spectrometry. See Annex C for confirmation test.

6.6 Blank test

Except for not taking sample, follow the above steps.

6.7 Parallel test

According to the above steps, perform the parallel test determination of the same sample.

7 Calculation of result

The content of aristolochic acid A in the sample is calculated by the chromatographic data processor or according to formula (1). […]

Annex C (informative) Confirmation test

C.1 Liquid chromatography reference conditions

Liquid chromatography reference conditions are as follows.

a) Chromatographic column. EclipsePlus C18 (150mm x 2.1mm, 1.8µm), or equivalent column;

b) Mobile phase. 5mmol/L ammonium acetate solution (pH adjusted to 7.5 with ammonia water) - acetonitrile = 75-25 (volume ratio);

c) Flow rate. 0.2mL/min;

d) Column temperature. 30°C;

e) Injection volume. 5µL.

C.2 Mass spectrometry reference conditions

Mass spectrometry reference conditions are as follows.

a) Ion source. electrospray ion source (ESI);

b) Ionization mode. positive ion mode;

c) Drying gas temperature. 350°C;

d) Dry gas flow. 10L/min;

e) Sheath gas temperature. 300°C;

f) Sheath gas flow. 7L/min;

g) Capillary voltage. 4000V;

h) Data acquisition. multiple response monitoring (MRM) mode.

C.3 Qualitative determination

When the sample is tested, the sample solution is diluted appropriately. Perform determination of sample solution and standard working solution by liquid chromatography-mass spectrometry. If the selected ions are present and the […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 35949-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35949-2018

$125.00