GB/T 35948-2018Determination of seven parabens in cosmetics—High performance liquid chromatography (English PDF)
化妆品中7种4-羟基苯甲酸酯的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35948-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35948-2018 is the English-translated version of 化妆品中7种4-羟基苯甲酸酯的测定 高效液相色谱法.
GB/T 35948-2018 describes a high performance liquid chromatography method for determining seven parabens in cosmetics: propyl, isopropyl, butyl, isobutyl, phenyl, benzyl and pentyl paraben.
It applies to creams, emulsions, gels, waters, powders and wax-based products, with a detection limit of 2 mg/kg and a quantitation limit of 6 mg/kg for each compound.
Samples are extracted with 95% ethanol, with acetonitrile for powders, or dispersed in cyclohexane and then extracted with acetonitrile for wax bases, before centrifuging, filtering and chromatography, with identification by retention time and chromatogram.
The standard covers reagents, apparatus, calculation, recovery between 85% and 110%, and the admissible error between two results. Annexes give data on the reference substances and example chromatograms. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35948-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative references5
- 3 Principle5
- 4 Reagents and materials6
- 5 Apparatus6
- 6 Analytical procedures7
- 7 Result calculation9
- 8 Recovery and accuracy9
- 9 Admissible error9
- Annex A (Informative) Chinese names, English names, CAS numbers, molecular formulas, relative molecular masses and constitutional formulas of paraben standard substances10
- Annex B (Informative) Liquid chromatograms and spectrograms of seven paraben standard substance solutions11
1 Scope
This Standard specifies the reagents and materials, apparatus, analytical procedures, result calculation, recovery and accuracy, admissible error, etc. for the determination of seven parabens in cosmetics using high performance liquid chromatography, including propylparaben, isopropylparaben, butylparaben, isobutylparaben, phenylparaben, benzylparaben and pentylparaben.
This Standard applies to the determination of seven parabens in cosmetics of creams, emulsions, gels, waters, powders, wax base, including propylparaben, isopropylparaben, butylparaben, isobutylparaben, phenylparaben, benzylparaben and pentylparaben.
The method detection limits of this Standard. all the method detection limits of seven parabens are 2 mg/kg.
The method quantitation limits of this Standard. all the method quantitation limits of seven parabens are 6 mg/kg.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition dated applies to this document. For undated references, the latest edition of the referenced documents (including all amendments) applies to this document.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Principle
Use ethanol 95% to extract sample of cosmetics of creams, emulsions, gels and waters; use acetonitrile to extract sample of powder cosmetics; use cyclohexane to disperse sample wax base cosmetics before using acetonitrile to extract; centrifuge and filter extract before using high performance liquid chromatography for determination. Carry out qualitative analysis based on the retention time and chromatogram and quantitative
6 Analytical procedures
6.1 Sample treatment
6.1.1 Sample of creams, emulsions, gels and waters
Weigh 0.5 g (accurate to 0.001 g) of sample to pour into a 10 mL graduated centrifugal tube with a stopper; add 8 mL of ethanol 95% (4.3); vibrate to mix up on vortex mixer (5.3); carry out ultrasonic extraction for 15 min; cool to room temperature; use ethanol 95% to add to metered volume of 10 mL. Take 2 mL of solution to a centrifugal tube; centrifuge for 2 min at 10 000 r/min; carry out determination after filtering using filter membrane (4.8).
6.1.2 Powder sample
Weigh 0.5 g (accurate to 0.001 g) of sample to pour into a 10 mL graduated centrifugal tube with a stopper; add 4 mL of acetonitrile (4.2); vibrate on vortex mixer for 1 min; carry out ultrasonic extraction for 15 min; centrifuge for 2 min at 2 000 r/min; transfer all liquid supernatant to a 10 mL colorimetric tube; add 4 mL of acetonitrile (4.2) to residuals to repeat extraction once; combine liquid supernatants; use acetonitrile (4.2) to add to metered volume of 10 mL. Take 2 mL of solution to a centrifugal tube; centrifuge for 2 min at 10 000 r/min; carry out determination after filtering using filter membrane (4.8).
6.1.3 Wax base sample
Weigh 0.5 g (accurate to 0.001 g) of sample to pour into a 10 mL graduated centrifugal tube with a stopper; add 2 mL of cyclohexane (4.4); vibrate to mix up on vortex mixer; add 4 mL of acetonitrile (4.2) to vibrate on vortex mixer for 1 min; carry out ultrasonic extraction for 15 min; centrifuge for 2 min at 2 000 r/min; transfer all liquid supernatant to a 10 mL colorimetric tube; add 4 mL of acetonitrile (4.2) to residuals to repeat extraction once; combine liquid supernatants; use acetonitrile (4.2) to add to metered volume of 10 mL. Take 2 mL of solution to a centrifugal tube; centrifuge for 2 min at 10 000 r/min; carry out determination after filtering using filter membrane (4.8).
6.2 Determination
6.2.1 Reference working conditions for high performance liquid chromatography
The reference working conditions for high performance liquid chromatography are as follows.
a) chromatographic column. core-shell type C18, 2.7 µm, 100 mm × 4.6 mm; or equivalent;
7 Result calculation
The content of parabens in sample is calculated in accordance with the following equation.
where.
Xi - the content tested constituents in sample, in mg/kg;
ci - the mass concentration of tested constituents in sample solution obtained from standard curve, in mg/L;
c0 - the mass concentration of tested constituents in blank sample obtained from standard curve, in mL;
V - the metered volume of sample solution, in mL;
m - the mass of sample, in g;
f - the dilution ratio.
Result is rounded off to two significant digits.
8 Recovery and accuracy
Within the range of adding concentration of 6 mg/kg ~ 60 mg/kg, the recovery is between 85% ~ 110% and the relative standard deviation is less than 10%.
9 Admissible error
The absolute difference between the results of two tests which are obtained independently under repeatable conditions, shall not exceed 10% of the arithmetic mean value. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35948-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35948-2018
$105.00