GB/T 35925-2018Determination of impurity fluorine ion in water soluble chemicals—Ion chromatography method (English PDF)
水溶性化工品中杂质氟离子的测定 离子色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35925-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35925-2018 is the English-translated version of 水溶性化工品中杂质氟离子的测定 离子色谱法.
GB/T 35925-2018 gives an ion chromatography method for measuring fluoride ion present as an impurity in water-soluble chemicals.
It applies to products with a fluoride content of up to 400 mg/kg, with quantitation limits of 0.02 mg/kg for organic chemicals and 4.0 mg/kg for inorganic chemicals, and it does not cover insoluble chemicals or chemicals whose main component contains fluorine.
The sample is brought into aqueous solution, with separate preparation steps for organic and alkali chemicals, then separated on an ion exchange column with a sodium hydroxide eluent and measured with a conductivity detector against a standard working curve.
The standard also covers result calculation and precision, and gives reference chromatographic conditions and chromatograms in its appendices. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35925-2018
National Standard of the People's Republic of China
- ICS
- 71.040.40
- Classification
- G 09
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Principle4
- 4 Reagents and Materials5
- 5 Apparatus5
- 6 Analytical Procedures5
- 7 Result Calculation7
- 8 Precision7
- Appendix A (Informative) Reference Chromatographic Conditions8
- Appendix B (Informative) Relevant Chromatograms of Determination of Impurity Fluoride ion in Water-Soluble Chemicals9
1 Scope
This Standard specifies the ion chromatographic method for the determination of impurity fluoride ion (F-) content in the water-soluble chemicals.
This Standard is applicable to the determination of fluoride ion content in water-soluble chemicals with fluoride ion content <=400mg/kg.
In this Standard, the quantitative limit of organic chemicals is 0.02mg/kg; while the quantitative limit of inorganic chemicals is 4.0mg/kg.
This Standard is not applicable to the insoluble chemicals and the chemicals with main component containing fluorine.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 6682 Water for Laboratory Use - Specifications
3 Principle
After treatment, the sample forms an aqueous solution; enters into the ion exchange chromatographic column with ion exchange resin as a stationary phase; the ion exchange resin is distributed by fixed charged group and free coordination ion; when eluted with a suitable eluent, the active exchange group on the ion exchange resin undergoes the ion exchange with ions in the test solution and ions in the eluent. As the eluent continues to flow, the anion in the test solution and the exchange group continue to occur exchanging - eluting - re-exchanging - re-eluting; depending on the different retention characteristics of the test anion on the chromatography column, the separation is realized; finally, the test anion is carried by the eluent to the detector and form a chromatographic peak. The group ion is qualitative by the retention time of each […]
6 Analytical Procedures
Organic chemicals. pipette 50mL of specimen into 100mL beaker; add 150µL of sodium hydroxide (4.2) to alkalinize; then evaporate to near dryness in water bath; dilute the slag with pure water; make constant volume into 10mL volumetric flask; perform ultrasound for 10min; stand for 60min; filter the supernatant by the filter membrane for testing.
Alkali chemicals. accurately take 1.0g~3.0g (accurate to 0.001g) of specimen into 50mL beaker; dissolve into water; then transfer to 100mL volumetric flask; dilute to the scale; perform the ultrasound for 10min; stand for 60min; take the supernatant to pass the hydrogen-type cation exchange cartridge; collect the filtrate to filter by the filtered membrane for testing.
6.2 Ion chromatographic conditions
a) Mobile phase. select according to the separation column, so that meet the requirements of separation in 5.5; meanwhile the main component can be eluted without disturbing the subsequent separation. For example, 20mmol/L sodium hydroxide solution (4.1).
b) Flowrate. 1.0mL/min.
c) Column temperature. 30°C.
d) Sample injection volume. 25µL.
e) Detector. conductivity detector.
6.3 Standard working curve
Preparation of standard working solution. take 10mL of fluoride ion standard stock solution (4.3) into a 100mL volumetric flask; dilute with water to the scale; then prepare the 10µg/mL fluoride ion standard solution. Separately take 0.4mL, 0.8mL, 1.0mL, 2.0mL, 4.0mL, 5.0mL, 20.0mL, 50.0mL of fluoride ion standard solution into 100mL volumetric flasks; dilute with water to the scale; then prepare the standard working solution with fluoride ion concentration of 0.04µg/mL, 0.08µg/mL, 0.1µg/mL, 0.2µg/mL, 0.4µg/mL, 0.5µg/mL, 2.0µg/mL, 5.0µg/mL; such solution shall be prepared for current use.
Take the above standard working solutions from the low to high concentrations into the ion chromatograph; draw a standard curve with ion concentration as abscissa and peak area as the ordinate. […]
6.4 Sample determination
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35925-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35925-2018
$125.00