GB/T 35837-2018Determination of prohibited minoxidil in cosmetics—High performance liquid chromatography (English PDF)
化妆品中禁用物质米诺地尔的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35837-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35837-2018 is the English-translated version of 化妆品中禁用物质米诺地尔的测定 高效液相色谱法.
GB/T 35837-2018 is the high performance liquid chromatography method for detecting minoxidil, a substance prohibited in cosmetics. It applies to emulsions, creams, lotions and shampoos with hair care and hair growth claims, with a detection limit of 5 mg/kg and a quantitative limit of 10 mg/kg.
The sample is extracted ultrasonically, centrifuged and analysed on a C18 column at 230 nm, and minoxidil is quantified by the external standard method. The standard covers the reagents, apparatus, sample preparation, chromatographic conditions, standard curve, result calculation, recovery rate, precision and allowable difference.
Annex A gives the chromatogram and UV spectrum of the reference substance, and Annex B a confirmation test by liquid chromatography-mass spectrometry in multiple reaction monitoring mode. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35837-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative References5
- 3 Principle5
- 4 Reagents and Materials5
- 5 Apparatus6
- 6 Analytical Procedures6
- 7 Result Calculation8
- 8 Detection Limit and Quantitative Limit8
- 9 Recovery Rate and Precision8
- 10 Allowable Difference8
- Appendix A (Informative) Structural Formula, High-Performance Liquid Chromatogram and UV Absorption Spectrum of Minoxidil Standard Substance9
- Appendix B (Informative) Confirmation Test11
1 Scope
This Standard specifies the high-performance liquid chromatography for the determination of prohibited substance of minoxidil in the cosmetics.
This Standard is applicable to the determination of minoxidil in the cosmetics, such as emulsions, creams, lotions and shampoos with hair care and growth functions.
This Standard's detection limit of minoxidil is 5mg/kg; while the quantitative limit is 10mg/kg.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principle
The specimen is ultrasonically extracted by the solvent; after centrifuging, determine by high performance liquid chromatography; quantify by external standard method; confirm by liquid chromatography-mass spectrometry.
4 Reagents and Materials
Unless otherwise stated, all the used reagents are analytical reagents; while the used water shall be Class-I water specified in GB/T 6682.
4.1 Methanol. chromatographically pure.
4.2 Trifluoroacetic acid. chromatographically pure. […]
6 Analytical Procedures
6.1.2 Lotion and shampoo samples
Take 0.5g (accurate to 0.001g) of specimen; place it into 10mL stoppered plastic centrifuge tube (5.6); add 10mL of 70% methanol aqueous solution (4.5); shake; perform ultrasonic extraction for 20min; after centrifuging for 15min at 5000r/min, filter the supernatant by the 0.45µm microporous membrane; then determine by the high-performance liquid chromatography.
6.2 Determination condition
The HPLC reference conditions are as follows.
a) Chromatographic column. C18, 5µm, 250mm×4.6mm (inner diameter), or the equivalent;
b) Flow rate. 1.0mL/min;
c) Mobile phase. methanol + 0.3% trifluoroacetic acid aqueous solution = 45 + 55 (volume ratio);
d) Detection wavelength. 230nm;
e) Column temperature. 30°C;
f) Sample-injecting volume. 10µL.
6.3 Drawing of the standard curve
Use 70% methanol aqueous solution (4.5) to dilute the minoxidil standard stock solution (4.6) grade by grade into the standard working solutions with concentrations of 0.5mg/L, 1mg/L, 2mg/L, 5mg/L, 10mg/L, and 20mg/L; inject sample and measure according to the low-to-high concentrations of the determination conditions in 6.2; take peak area-concentration as diagram to draw standard working curve.
The high-performance liquid chromatogram of the minoxidil standard substance can refer to Figure A.2 in Appendix A; while the UV absorption spectrum of the minoxidil standard substance can refer to Figure A.3 in Appendix A.
6.4 Determination
Determine the to-be-tested sample as per the determination conditions in 6.2; if the retention time of the chromatographic peak of the detected minoxidil is consistent with the standard substances; in the chromatogram of the sample after subtracting the background, the UV absorption spectrum with such substance is consistent with the standard substance; then it can be preliminarily determined that the minoxidil is present in the sample; use the external standard method to quantify. The minoxidil content shall be within the standard curve; if the linear range is exceeded, then dilute it and analyze.
Appendix B (Informative) Confirmation Test
B.1 Liquid chromatography conditions
The reference conditions of liquid chromatography determination are as follows.
a) Chromatographic column. XBridge C18, 3.5µm, 150mm×2.1mm (inner diameter), or the equivalent;
b) Mobile phase. 0.1% formic acid solution + acetonitrile = 10+90 (volume ratio);
c) Flow rate. 0.4mL/min;
d) Column temperature. 40°C;
e) Sample-injecting volume. 5µL.
B.2 Mass spectrometry conditions
The reference conditions of mass spectrometry determination are as follows.
a) Ion source. electrospray ion source;
b) Ionization mode. positive ion mode;
c) Capillary voltage. 3kV;
d) Extraction voltage. 3V;
e) Ion source temperature. 150°C;
f) De-solvent gas. nitrogen;
g) De-solvent gas flow rate. 800L/h;
h) De-solvent gas temperature. 500°C;
i) Data collection method. multiple reaction monitoring (MRM).
B.3 Qualitative determination
When measuring the sample solution, appropriately dilute it; measure the sample solution and standard working solution as per the determination conditions of liquid […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35837-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35837-2018
$125.00