GB/T 35829-2018Determination of four naphthalenediols in cosmetics—High performance liquid chromatography (English PDF)
化妆品中4种萘二酚的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35829-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35829-2018 is the English-translated version of 化妆品中4种萘二酚的测定 高效液相色谱法.
GB/T 35829-2018 specifies a high performance liquid chromatography method for determining 1,7-, 2,3-, 1,5- and 2,7-naphthalenediol in cosmetics.
It applies to non-wax-based creams, lotions, gels, water and powder products: cream, lotion, gel and water samples are extracted with 95% ethanol, powders with 95% ethanol and 0.1% acetic acid, and the filtered extract is analysed by HPLC with external standard quantification.
The method detection limit for the four naphthalenediols is 2.5 mg/kg and the quantification limit 7.5 mg/kg.
The standard covers reagents, apparatus, specimen processing, chromatographic conditions, calculation of results, recovery rate, precision and allowable deviation, and an annex describes a confirmation test by liquid chromatography with mass spectrometry. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35829-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative References5
- 3 Principles5
- 4 Reagents and Materials6
- 5 Apparatus6
- 6 Analytical Procedures7
- 7 Results Calculation8
- 8 Recovery Rate and Precision9
- 9 Allowable Deviation9
- Appendix A (Informative) Information on Naphthalenediol Standard Substance10
- Appendix B (Informative) Liquid Chromatogram and Spectrogram of Four Naphthalenediols Standard Substance Solutions11
- Appendix C (Informative) Confirmation Test14
1 Scope
This Standard specifies high performance liquid chromatography for the determination of 1,7-naphthalenediol, 2,3-naphthalenediol, 1,5-naphthalenediol and 2,7-naphthalenediol in cosmetics.
This Standard is applicable to the determination of 1,7-naphthalenediol, 2,3-naphthalenediol, 1,5-naphthalenediol and 2,7-naphthalenediol in non-wax-based cream, lotion, gel, water and powder cosmetics.
The method detection limit of this Standard. the method detection limit of four naphthalenediols is 2.5mg/kg.
The method quantification limit of this Standard. the method quantification limit of four naphthalenediols is 7.5mg/kg.
2 Normative References
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods
3 Principles
The samples of cream, lotion, gel and water cosmetics shall be directly extracted by 95% ethanol; the samples of powder cosmetics shall be extracted by the mixture of 95% ethanol and 0.1% acetic acid solutions; the extracting solution shall be determined by high-performance liquid chromatography after the filtering and centrifuging.
According to the retention time and spectrogram qualitative, use the external standard quantitative method; if necessary, use liquid chromatography-mass spectrometry/mass spectrometry to verify.
6 Analytical Procedures
6.1 Specimen processing
6.1.1 Cream, lotion and water specimens
Take 0.5g (accurate to 0.001g) of specimen; place it into 10mL stoppered colorimetric tube; add 4mL of 95% ethanol (4.3); shake and mix on the vortex oscillator (5.3); then perform ultrasonic extraction for 15min; cool off to the room temperature; use 95% ethanol (4.3) to make constant volume to 5mL. Take 2mL of solution into the centrifuge tube; centrifuge for 2min at 10000r/min; filter the supernatant through a filter membrane (4.8) then determined by the high-performance liquid chromatography (5.1).
6.1.2 Powder specimen
Take 0.5g (accurate to 0.001g) of specimen; place it into 10mL stoppered colorimetric tube; add 2mL of 95% ethanol (4.3); shake and mix on the vortex oscillator (5.3); then add 2mL of 0.1% acetic acid solution (4.4); perform ultrasonic extraction for 15min; cool off to the room temperature; use 95% ethanol (4.3) to make constant volume to 5mL. Take 2mL of solution into the centrifuge tube; centrifuge for 2min at 10000r/min; filter the supernatant through a filter membrane (4.8) then determined by the high-performance liquid chromatography (5.1).
6.2 Determination
6.2.1 Reference operating conditions of high-performance liquid chromatograph
The reference operating conditions of high-performance liquid chromatograph are as follows.
a) Chromatographic column. C18 column, 5µm, 250mm×4.6mm (inner diameter), or the equivalent;
b) Mobile phase. methanol (4.1) and 0.1% acetic acid solution (4.4), high-performance liquid chromatograph gradient elution conditions are shown in Table 1;
c) Flow rate. 1.0mL/min;
d) Column temperature. 30°C;
e) Wavelength. 230nm;
f) Sampling-injecting volume. 20µL. […]
7 Results Calculation
Where:
Xi - the content of the test composition in the specimen; in mg/kg; ci - the mass concentration of the test composition in the specimen solution obtained from the standard curve; in µg/mL; c0 - the mass concentration of the test composition in the blank sample obtained from the standard curve; in µg/mL;
V - the constant volume of the specimen solution, in mL; m - specimen mass, in g; f - dilution factor. The results shall be retained two significant figures.
8 Recovery Rate and Precision
In the range of add concentration of 7.5mg/kg ~75mg/kg, the recovery rate is 80%~110%; the relative standard deviation is less than 10%.
9 Allowable Deviation
The absolute difference between two independent determinations obtained under repeatability conditions shall not exceed 10% of the arithmetic mean.
Appendix C (Informative) Confirmation Test
C.1 Liquid chromatography reference conditions
The liquid chromatography reference conditions are as follows.
a) Chromatographic column. Luna C18(2), 150×2.0mm (inner diameter), 3µm; or the equivalent;
b) Mobile phase. A - methanol; B - water; gradient elution. 0.0min~10.0min, 25%~65%A; 10.1min~30.0min, 65%A.
c) Flow rate. 150µL/min;
d) Column temperature. 25°C;
e) Sample-injecting volume. 10µL.
C.2 Mass spectrometry reference conditions
The mass spectrometry reference conditions are as follows.
a) Ion source. electrospray ion source;
b) Ionization mode. negative ion mode;
c) Ionization voltage. -4500V;
d) Atomizing gas pressure. 0.345MPa (50psi);
e) Air curtain gas pressure. 0.241MPa (35psi);
f) Auxiliary heating gas pressure. 0.483MPa (70psi);
g) Auxiliary gas temperature. 500°C;
h) Detection mode. Multiple Reaction Monitoring (MRM) mode. The mass spectrometric analysis parameters of four naphthalenediols can refer to Table C.1; the multiple reaction monitoring mass chromatograms of four naphthalenediols can refer to Figure C.1. […]
C.3 Qualitative determination
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35829-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35829-2018
$115.00