Scope

GB/T 35828-2018 is the English-translated version of 化妆品中铬、砷、镉、锑、铅的测定 电感耦合等离子体质谱法.

GB/T 35828-2018 is the Chinese national method for determining chromium, arsenic, cadmium, antimony (stibium) and lead in cosmetics by inductively coupled plasma mass spectrometry (ICP-MS).

It applies to products such as creams, body lotions, lip glosses, lipsticks, liquid eyeliners, foundations, perfumes, nail polishes, bath foams and shampoos. The detection limit is 0.07 mg/kg for chromium, arsenic, antimony and lead and 0.04 mg/kg for cadmium, with limits of quantification of 0.2 mg/kg and 0.1 mg/kg.

The standard covers the principle, reagents, instruments, microwave digestion of the sample, the standard series with internal standard, the determination, result calculation, recovery, precision and tolerance, with ICP-MS operating conditions in Annex A. Cosmetics testing laboratories use it. It was issued on 6 February 2018 and has applied since 1 September 2018.

Found what you need?

Document preview — GB/T 35828-2018

National Standard of the People's Republic of China

ICS
71.100.70
Classification
Y 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative references5
  • 3 Principles5
  • 4 Reagents and materials6
  • 5 Instruments and equipment6
  • 6 Analytical procedures7
  • 7 Result calculation9
  • 8 Recovery rate and precision9
  • 9 Tolerance10
  • Appendix A (Informative) Operating conditions for inductively coupled plasma mass spectrometer (ICP-MS)11

1 Scope

This Standard specifies inductively coupled plasma mass spectrometry for the determination of chromium, arsenic, cadmium, stibium, and lead in cosmetics.

This Standard applies to inductively coupled plasma mass spectrometry for the determination of chromium, arsenic, cadmium, stibium, and lead in cosmetics such as creams, body lotions, lip glosses, lipsticks, liquid eyeliners, liquid foundations, perfumes, nail polishes, bath foams, and shampoos.

The detection limit of this Standard for the determination of chromium, arsenic, stibium, and lead is 0.07 mg/kg; the limit of quantification is 0.2 mg/kg. The detection limit for cadmium is 0.04 mg/kg; the limit of quantification is 0.1 mg/kg.

2 Normative references

The following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document.

GB/T 6682 Water for analytical laboratory use - Specification and test methods

3 Principles

After the sample is digested, it is determined by inductively coupled plasma mass spectrometer (ICP-MS). ICP-MS consists of two main parts. ion source and mass spectrometer. After the atomization of the sample solution, it is sent by the carrier gas to the ICP torch flame. Through evaporation, dissociation, atomization, ionization, and other processes, it is converted into positively charged ions. After ion focusing, it enters the mass spectrometer. In the mass spectrometer, according to the specific mass-to-charge ratio (m/z) of the element, it is separated and collected. For a certain mass-to-charge ratio, the mass spectral response value is directly proportional to the number of ions entering the mass spectrometer, that is, the mass spectral signal intensity is […]

6 Analytical procedures

6.3 Preparation of standard series

PIPETTE 0.00 mL, 1.00 mL, 5.00 mL, 10.00 mL of secondary standard intermediate solution (4.9) and 0.50 mL, 1.00 mL, 2.00 mL of primary standard intermediate solution (4.8) respectively into 100 mL volumetric flasks. Then ADD 2.00 mL of internal standard working solution (4.10) respectively; USE dilute nitric acid solution (4.3) to dilute to volume; and SHAKE well. The standard concentrations of chromium, stibium, cadmium, arsenic, and lead are 0.00 ng/mL, 1.00 ng/mL, 5.00 ng/mL, 10.00 ng/mL, 50.00 ng/mL, 100.00 ng/mL, 200.00 ng/mL.

6.4 Reference conditions for inductively coupled plasma mass spectrometer (ICP-MS)

According to the interference elimination mode provided by the instrument manufacturer, optimize the determination conditions. If there is no suitable interference elimination mode, Appendix A can be referred to for optimization.

6.5 Determination

After using the tuning solution to adjust each index of the instrument with the instrument sensitivity, precision (RSD), oxide, double charge, peak shape, and resolution meeting the determination requirements, the standard series, reagent blank, and sample solution are determined respectively. The determination mass of the elements to be tested and internal standard elements is shown in Table 1. ENTER each parameter; DRAW a standard curve; and calculate the regression equation. If the determination result exceeds the linear range of the standard curve, the sample shall be diluted and then determined.

The blank test, except for the absence of sample, uses exactly the same analytical procedures, reagents, and dosages. The number of parallel determinations is not less than two. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 35828-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35828-2018

$115.00