GB/T 35803-2018Determination of prohibited urocanic acid and its ethyl ester in cosmetics—High performance liquid chromatography (English PDF)
化妆品中禁用物质尿刊酸及其乙酯的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35803-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35803-2018 is the English-translated version of 化妆品中禁用物质尿刊酸及其乙酯的测定 高效液相色谱法.
GB/T 35803-2018 is a high performance liquid chromatography method for determining urocanic acid and its ethyl ester, both prohibited in cosmetics, in creams, liquids, lipsticks, loose powders and shampoos.
The detection limit is 2 mg/kg and the limit of quantification 5 mg/kg. The sample is extracted with methanol in an ultrasonic bath, with tetrahydrofuran added first for lipsticks, then centrifuged, concentrated by nitrogen blowing, diluted with water and filtered through a 0.45 µm membrane.
The chromatographic conditions use a C18 column, a methanol and tetrabutylammonium bromide mobile phase and detection at 285 nm, with external standard quantification.
The standard also covers result calculation, recovery, precision and tolerance, and an annex confirms positives by liquid chromatography-mass spectrometry. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35803-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents and materials
- 5 Apparatus and equipment
- 6 Analysis steps
- 7 Result calculation
- 8 Detection limit and limit of quantification
- 9 Recovery rate and precision
- 10 Tolerance
- Annex A (informative) Chinese name, English name, CAS number, molecular formula, relative molecular mass, structural formula of urocanic acid and its ethyl ester
- Annex C (informative) Test of confirmation
1 Scope
This Standard specifies determination method of high performance liquid chromatography for prohibited urocanic acid and its ethyl ester in cosmetics.
This Standard is applicable to determination of urocanic acid and its ethyl ester in cosmetics such as creams, liquids, lipsticks, loose powders, shampoos.
The detection limit of this Standard for urocanic acid and its ethyl ester is 2 mg/kg, and the limit of quantification is 5 mg/kg.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Principle
After the specimen is centrifuged by solvent and is centrifuged, after the supernatant is filtered by nitrogen blowing capacity, use high performance liquid chromatography to determine, use external standard method to quantify, use liquid chromatography-mass spectrometry to confirm.
4 Reagents and materials
Unless otherwise stated, the reagents used are analytically pure, the water is of grade one specified in GB/T 6682.
4.1 Methanol. chromatographically pure. […]
5 Apparatus and equipment
5.5 Ultrasonic cleaner.
5.6 Nitrogen blower.
5.7 Plugged plastic centrifuge tube. 10mL.
5.8 Graduated nitrogen blow tube. 10mL.
5.9 Microporous membrane. 0.45µm, made of PTFE. […]
6 Analysis steps
6.1 Sample processing
6.1.1 Cream, liquid, loose powder and shampoo samples
Weigh 0.2g (to the nearest of 0.001g) of specimen in a 10mL plugged plastic centrifuge tube (5.7). Add into 10mL of methanol (4.1). Shake well. After performing ultrasonic extraction for 20min, centrifugation at 8000r/min for 15min, transfer the supernatant to the graduated nitrogen blow tube (5.8). Slow the nitrogen blowing to 1mL. Add into 9mL of water. Mix well. It is filtered through a 0.45µm microporous membrane for high performance liquid chromatography.
6.1.2 Lipstick sample
Weigh 0.2g (to the nearest of 0.001g) of specimen in a 10mL plugged plastic centrifuge tube (5.7). Add into 0.5mL of tetrahydrofuran (4.2). Then add into 9.5mL of methanol (4.1). Shake well. Performing ultrasonic extraction for 20min, centrifugation at 8000r/min for 15min. Transfer the supernatant to the graduated nitrogen blow tube (5.8). Slow the nitrogen blowing to 1mL. Add into 9mL of water. Mix well. It is filtered through a 0.45µm microporous membrane for high performance liquid chromatography.
6.2 Determination conditions
The reference conditions for high performance liquid chromatography are as follows.
a) Chromatographic column. Xterra MS C18, 5µm, 250mm × 4.6mm (inner diameter), or the equivalent;
b) Flow rate. 1.0mL/min;
c) Mobile phase. methanol + 0.005mol/L tetrabutylammonium bromide solution=30+70 (volume ratio);
d) Detection wavelength. 285nm; […]
Annex C (informative) Test of confirmation
C.1 Liquid chromatography conditions
The reference conditions for liquid chromatography determination are as follows.
a) Chromatographic column. XBridge C18, 3.5µm, 150mm × 2.1mm (inner diameter);
b) Mobile phase. 0.1% formic acid solution + acetonitrile = 95 + 5 (volume ratio);
c) Flow rate. 0.3mL/min;
d) Column temperature. 30°C;
e) Injection volume. 5µL.
C.2 Mass spectrometry conditions
The reference conditions for mass spectrometry are as follows.
a) Ion source. electrospray ion source;
b) Ionization mode. positive ion mode;
c) Capillary voltage. 3kV;
d) Extraction voltage. 2.9V;
e) Ion source temperature. 150°C;
f) Desolvation gas temperature. 350°C;
g) Data collection method. multiple reaction monitoring.
C.3 Qualitative determination
When the specimen is measured, the sample solution is appropriately diluted, and the sample solution and the standard working solution are determined according to liquid chromatography-mass spectrometry conditions. If the selected ions are present, and the selected ion ratio is consistent with the […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35803-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35803-2018
$125.00