GB/T 35801-2018Determination of prohibited captan in cosmetics—High performance liquid chromatography (English PDF)
化妆品中禁用物质克霉丹的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35801-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 35801-2018 is the English-translated version of 化妆品中禁用物质克霉丹的测定 高效液相色谱法.
GB/T 35801-2018 is the Chinese national method for determining captan, a substance prohibited in cosmetics, by high performance liquid chromatography. It applies to creams, liquids and loose powder cosmetics, with a detection limit of 2 mg/kg and a limit of quantification of 5 mg/kg.
The sample is extracted ultrasonically with solvent and centrifuged, then determined by HPLC with a C18 column and detection at 206 nm, and quantified by the external standard method.
Positive samples can be confirmed by liquid chromatography-mass spectrometry, whose conditions are given in Annex B. The standard also covers reagents, apparatus, calculation of results, recovery, precision and tolerance.
Cosmetics testing laboratories use it. It was issued on 6 February 2018 and has applied since 1 September 2018.
Found what you need?
Document preview — GB/T 35801-2018
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- Introduction4
- 1 Scope5
- 2 Normative references5
- 3 Principle5
- 4 Reagents and materials5
- 5 Apparatus and equipment6
- 6 Analysis steps6
- 7 Result calculation8
- 8 Detection limit and limit of quantification8
- 9 Recovery rate and precision8
- 10 Tolerance8
- Annex A (informative) Structural formula, high performance liquid chromatogram and ultraviolet absorption spectrum of the captan standard product9
- Annex B (informative) Test of confirmation11
1 Scope
This Standard specifies determination method of high performance liquid chromatography for prohibited captan in cosmetics.
This Standard is applicable to determination of captan in creams, liquids, loose powder cosmetics.
The detection limit of this Standard for captan is 2 mg/kg, and the limit of quantification is 5 mg/kg.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6682, Water for analytical laboratory use - Specification and test methods
3 Principle
After the specimen is ultrasonically extracted by solvent and is centrifuged, use high performance liquid chromatography to determine, use external standard method to quantify, use liquid chromatography-mass spectrometry to confirm.
4 Reagents and materials
Unless otherwise stated, the reagents used are analytically pure, the water is of grade one specified in GB/T 6682.
4.1 Acetonitrile. chromatographically pure.
4.2 Methanol. chromatographically pure.
4.3 Tetrahydrofuran. […]
6 Analysis steps
6.1.2 Liquid and loose powder samples
Weigh 1g (to the nearest of 0.001g) of sample. Place in a 10mL plugged plastic centrifuge tube (5.6). Shake well. Add into 10mL of methanol (4.2). After performing ultrasonic extraction for 20min, centrifugation at 5000r/min for 15min, the supernatant is filtered through a 0.45µm microporous membrane for determination of high performance liquid chromatography.
6.2 Determination conditions
The reference conditions for high performance liquid chromatography are as follows.
a) Chromatographic column. C18, 5µm, 250mm × 4.6mm (inner diameter), or the equivalent;
b) Flow rate. 1.0mL/min;
c) Mobile phase. acetonitrile + water = 65 + 35 (volume ratio);
d) Detection wavelength. 206nm;
e) Column temperature. 30°C;
f) Injection volume. 10µL.
6.3 Drawing of standard curve
The captan standard working solution (4.7) was determined according to the determination conditions in 6.2 and the concentration from low to high injection. Draw in peak area-concentration. Make standard working curve.
See Figure A.2 in Annex A for a high performance liquid chromatogram of the captan standard solution. The UV absorption spectrum of the captan standard product is shown in Figure A.3 of Annex A.
6.4 Determination
Conduct determination for the testing sample according to the determination conditions in 6.2. If the retention time of the chromatographic peak detected is consistent with the standard product, and the chromatogram of the sample after subtracting the background, the UV absorption spectrum of the substance is consistent with the standard product, it can be preliminarily determined that captan exists in the sample. Use external standard method to quantify. The content of captan shall be within the standard curve. If it is outside the linear range, it shall be diluted before analysis. If necessary, positive sample shall be confirmed by liquid chromatography-mass spectrometry. See Annex B for confirmation test.
Annex B (informative) Test of confirmation
B.1 Liquid chromatography conditions
The reference conditions for liquid chromatography determination are as follows.
a) Chromatographic column. XBridge C18, 3.5µm, 150mm × 2.1mm (inner diameter);
b) Mobile phase. 0.1% formic acid solution + acetonitrile = 10 + 90 (volume ratio);
c) Flow rate. 0.3mL/min;
d) Column temperature. 30°C;
e) Injection volume. 5µL.
B.2 Mass spectrometry conditions
The reference conditions for mass spectrometry are as follows.
a) Ion source. electrospray ion source;
b) Ionization mode. positive ion mode;
c) Capillary voltage. 3.5kV;
d) Extraction voltage. 3.0V;
e) Ion source temperature. 150°C;
f) Desolvation gas temperature. 500°C;
g) Data collection method. multiple reaction monitoring.
B.3 Qualitative determination
When the specimen is measured, the sample solution is appropriately diluted, and the sample solution and the standard working solution are determined according to liquid chromatography-mass spectrometry conditions. If the selected ions are present, and the selected ion ratio is consistent with the […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 35801-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-1992 — Water for analytical laboratory use--Specification and test methods
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 35801-2018
$125.00